Factors affecting the water odor caused by chloramines during drinking water disinfection

被引:25
|
作者
Wang, An-Qi [1 ,2 ]
Lin, Yi-Li [3 ]
Xu, Bin [1 ,2 ]
Hu, Chen-Yan [4 ]
Gao, Ze-Chen [1 ]
Liu, Zhi [1 ]
Cao, Tong-Cheng [5 ]
Gao, Nai-Yun [1 ]
机构
[1] Tongji Univ, State Key Lab Pollut Control & Resource Reuse, Key Lab Yangtze Water Environm, Coll Environm Sci & Engn,Minist Educ, Shanghai 200092, Peoples R China
[2] Shanghai Inst Pollut Control & Ecol Secur, Shanghai 200092, Peoples R China
[3] Natl Kaohsiung Univ Sci & Technol, Dept Safety Hlth & Environm Engn, Kaohsiung 824, Taiwan
[4] Shanghai Univ Elect Power, Coll Environm & Chem Engn, Shanghai 200090, Peoples R China
[5] Tongji Univ, Sch Chem Sci & Engn, Shanghai 200092, Peoples R China
关键词
Flavor profile analysis; Drinking water odor; Monochloramine decay; Dichloramine; ORGANIC CHLORAMINES; NDMA FORMATION; TAP WATER; CHLORINATION; TASTE; KINETICS; MODEL; DECAY;
D O I
10.1016/j.scitotenv.2018.05.188
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chloramine disinfection is one of the most common disinfection methods in drinking water treatment. In this study, the temporal variability of water odors during monochloramine auto-decomposition was investigated to elucidate the characteristics of odor problems caused by adopting chloramine disinfection in tap water. Odor intensities and dominant odorant contributions were determined using the flavor profile analysis (FPA) and odor active value (OAV), respectively. During auto-decomposition of monochloramine, Cl-2/N molar ratio, pH, temperature, and the presence of NOM all affected odor intensity and odor temporal variation in drinking water. In general, decreasing pH from 8.5 to 6.0 led to increasing perceived odor intensity due to the formation of dichloramine. The major odorants responsible for chlorinous odor under acidic and non-acidic conditions were dichloramine and monochloramine, respectively. Chloraminated water with a Cl-2/N molar ratio of 0.6 or NOM concentration <2 mg-C L-1 inhibited odor intensity. Furthermore, the influence of rechlorination on chlorinous odor intensity for chloraminated water should not be neglected. The results of this study will be beneficial for the control of chlorinous odors caused by chloramine disinfection in drinking water. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:687 / 694
页数:8
相关论文
共 50 条
  • [1] Investigation of Chloramines, Disinfection Byproducts, and Nitrification in Chloraminated Drinking Water Distribution Systems
    Abulikemu, Gulizhaer
    Mistry, Jatin H.
    Wahman, David G.
    Alexander, Matthew T.
    Kennicutt, Alison R.
    Bollman, Jacob D.
    Pressman, Jonathan G.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2023, 149 (01)
  • [2] Effect of disinfection method on odor and disinfection byproduct control in drinking water treatment
    Ma, Cong
    Shi, Wenxin
    Wang, Liang
    Zhao, Xi
    Zhao, Bin
    Guo, Xingfei
    Zhang, Zhaohui
    Zhang, Hongwei
    DESALINATION AND WATER TREATMENT, 2016, 57 (17) : 7753 - 7762
  • [3] Factors affecting the formation of nitrogenous disinfection by-products during chlorination of aspartic acid in drinking water
    Chen, Wei
    Liu, Zhigang
    Tao, Hui
    Xu, Hang
    Gu, Yanmei
    Chen, Zhaolin
    Yu, Jingjing
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 575 : 519 - 524
  • [4] WHAT CAUSED THE BAD ODOR IN THE DRINKING-WATER
    GERARDI, MH
    WATER-ENGINEERING & MANAGEMENT, 1981, 128 (06): : 63 - 65
  • [5] MODELING THE DISTRIBUTION OF CHLORAMINES DURING DRINKING-WATER CHLORAMINATION
    YOON, JY
    JENSEN, JN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 22 - ENVR
  • [6] Formation of organic chloramines during water disinfection - chlorination versus chloramination
    Lee, Wontae
    Westerhoff, Paul
    WATER RESEARCH, 2009, 43 (08) : 2233 - 2239
  • [7] Factors affecting drinking water biofiltration
    Liu, XB
    Huck, PM
    Slawson, RM
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2001, 93 (12): : 90 - 101
  • [8] Factors affecting the genotoxicity of drinking water
    Xu, Zhizhen
    Wang, Dongsheng
    Zhang, Rong
    Tang, Shichuan
    ADVANCES IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-6, 2012, 518-523 : 922 - +
  • [9] Drinking water disinfection
    Savluk, O.S.
    Potapchenko, N.G.
    Kosinova, V.N.
    Dianzi Kexue Xuekan/Journal of Electronics, 1998, 20 (06): : 99 - 111
  • [10] Formation and Decomposition of N-Chloroaldimines in Drinking Water Disinfection: An Overlooked Subclass of Organic Chloramines
    Wu, Yuwei
    Huang, Yuanxi
    Zhu, Shumin
    Wu, Yangtao
    Bu, Lingjun
    Zhou, Shiqing
    Chu, Wenhai
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2025, 59 (13) : 6778 - 6786