Failure Diagnosis of Demagnetization in Interior Permanent Magnet Synchronous Motors Using Vibration Characteristics

被引:14
作者
Ishikawa, Takeo [1 ]
Igarashi, Naoto [1 ]
机构
[1] Gunma Univ, Div Elect & Informat, Kiryu, Gunma 3768515, Japan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 15期
关键词
failure diagnosis; demagnetization; interior permanent magnet synchronous motor; vibration; FAULT-DIAGNOSIS; TIME-DOMAIN;
D O I
10.3390/app9153111
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of a precursor to the demagnetization of permanent magnets is very important because a high degree of reliability is necessary in permanent magnet synchronous motors (PMSMs). This paper investigated the diagnosis of very slight PM demagnetization. A part of the permanent magnet was altered to non-magnetic material so as to mimic the effect of demagnetization. The vibration characteristics were clarified for low demagnetization in PMSMs driven under vector control by experiments and 3D finite element (FE) analysis. We found that the amplitude of some components of the vibration was approximately proportional to the demagnetization level of the PM and the load torque. Therefore, the measurement of vibration and torque is very useful for the estimation of the magnetization level of PMSMs under vector control except for under very light load.
引用
收藏
页数:13
相关论文
共 31 条
[12]   Rolling bearing fault detection of electric motor using time domain and frequency domain features extraction and ANFIS [J].
Helmi, Hamed ;
Forouzantabar, Ahmad .
IET ELECTRIC POWER APPLICATIONS, 2019, 13 (05) :662-669
[13]   Estimation of sensor faults and unknown disturbance in current measurement circuits for PMSM drive system [J].
Huang, Gang ;
Fukushima, Edwardo F. ;
She, Jinhua ;
Zhang, Changfan ;
He, Jing .
MEASUREMENT, 2019, 137 :580-587
[14]   Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors [J].
Ishikawa T. ;
Igarashi N. ;
Kurita N. .
International Journal of Rotating Machinery, 2017, 2017
[15]   Online Estimation of the Rotor Flux Linkage and Voltage-Source Inverter Nonlinearity in Permanent Magnet Synchronous Machine Drives [J].
Liu, Kan ;
Zhu, Z. Q. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (01) :418-427
[16]   Application of Infrared Thermography to Failure Detection in Industrial Induction Motors: Case Stories [J].
Lopez-Perez, David ;
Antonino-Daviu, Jose .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2017, 53 (03) :1901-1908
[17]   Effects of Rotor Position Error on Longitudinal Vibration of Electric Wheel System in In-Wheel PMSM Driven Vehicle [J].
Mao, Yu ;
Zuo, Shuguang ;
Cao, Jianan .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2018, 23 (03) :1314-1325
[18]   Incipient Broken Rotor Bar Detection in Induction Motors Using Vibration Signals and the Orthogonal Matching Pursuit Algorithm [J].
Morales-Perez, Carlos ;
Rangel-Magdaleno, Jose ;
Peregrina-Barreto, Hayde ;
Pablo Amezquita-Sanchez, Juan ;
Valtierra-Rodriguez, Martin .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (09) :2058-2068
[19]   Analysis of Statistical Time-Domain Features Effectiveness in Identification of Bearing Faults From Vibration Signal [J].
Nayana, B. R. ;
Geethanjali, P. .
IEEE SENSORS JOURNAL, 2017, 17 (17) :5618-5625
[20]   Online Detection of Rotor Eccentricity and Demagnetization Faults in PMSMs Based on Hall-Effect Field Sensor Measurements [J].
Park, Yonghyun ;
Fernandez, Daniel ;
Lee, Sang Bin ;
Hyun, Doosoo ;
Jeong, Myung ;
Kommuri, Suneel Kumar ;
Cho, Changhee ;
Reigosa, David Diaz ;
Briz, Fernando .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (03) :2499-2509