Quantitative small animal PET imaging with nonconventional nuclides

被引:38
作者
Liu, Xiaodong [1 ]
Laforest, Richard [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
microPET; Nonconventional nuclides; Cascade gamma-rays; Spatial resolution; Recovery coefficients; POSITRON-EMISSION-TOMOGRAPHY; MAXIMUM A-POSTERIORI; CERVICAL-CANCER; RADIATION; RADIOPHARMACEUTICALS; ANTIBODIES; EMITTERS; QUALITY; BR-76; Y-86;
D O I
10.1016/j.nucmedbio.2009.01.019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron Emission Tomography (PET) has gained a tremendous momentum recently for clinical applications notably with the availability of F-18-tluorodeoxyglucose for staging and evaluation of therapy efficacy in various types of cancers. Nonconventional positron emitting nuclides are now being investigated for the development of novel imaging and therapeutic strategies. However, these nuclides have less than ideal imaging properties. This article compares the performance for imaging of nonconventional nuclides such as Cu-61, Ga-68, Y-86 and (TC)-T-94m with the standard imaging nuclide F-18 for high-resolution small animal PET imaging. Quantitative imaging performance was evaluated in terms of spatial resolution and hot spheres recovery coefficients from image resolution and image quality phantoms representing the mouse. The data were reconstructed using algorithms of 2D filtered-back-projection, 2D ordered-subsets expectation maximization and maximum-a-posteriori. It is shown that the spatial resolution point spread Function can be well explained by a double-gaussian function due to the generally long range of the positron. We show that, with the knowledge of the measured point spread functions, the accurate activity concentration in small lesions can be recovered when imaging with long-range positron emitters. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 40 条
  • [1] Improved quantification for Tc-94m PET imaging
    Barker, WC
    Szajek, LP
    Green, SL
    Carson, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 739 - 742
  • [2] Beattie BJ, 2001, J NUCL MED, V42, p201P
  • [3] Advances in the production, processing and microPET image quality of technetium-94m
    Bigott, Heather M.
    Laforest, Richard
    Liu, Xiaodong
    Ruangma, Ananya
    Wuest, Frank
    Welch, Michael J.
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2006, 33 (07) : 923 - 933
  • [4] Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET
    Chatziioannou, A
    Qi, J
    Moore, A
    Annala, A
    Nguyen, K
    Leahy, R
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 507 - 512
  • [5] Assessing tumor hypoxia in cervical cancer by PET with 60Cu-labeled diacetyl-bis(N4-methylthiosemicarbazone)
    Dehdashti, Farrokh
    Grigsby, Perry W.
    Lewis, Jason S.
    Laforest, Richard
    Siegel, Barry A.
    Welch, Michael J.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (02) : 201 - 205
  • [6] Dupont S, 1999, J NUCL MED, V40, P935
  • [7] Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods
    El Naqa, Issam
    Low, Daniel A.
    Bradley, Jeffrey D.
    Vicic, Milos
    Deasy, Joseph O.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3587 - 3600
  • [8] FLOWER MA, 1994, EUR J NUCL MED, V21, P531
  • [9] Tumor delineation using PET in head and neck cancers: Threshold contouring and lesion volumes
    Ford, Eric C.
    Kinahan, Paul E.
    Hanlon, Lorraine
    Alessio, Adam
    Rajendran, Joseph
    Schwartz, David L.
    Phillips, Mark
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4280 - 4288
  • [10] PET quantitation and imaging of the non-pure positronemitting iodine isotope 124I
    Herzog, H
    Tellmann, L
    Qaim, SM
    Spellerberg, S
    Schmid, A
    Coenen, HH
    [J]. APPLIED RADIATION AND ISOTOPES, 2002, 56 (05) : 673 - 679