The effect of high frequency steep pulsed electric fields on in vitro and in vivo antitumor efficiency of ovarian cancer cell line skov3 and potential use in electrochemotherapy

被引:15
|
作者
Yang, Xiao-Jun [1 ]
Li, Jun [2 ]
Sun, Cai-Xin [3 ]
Zheng, Fei-Yun [1 ]
Hu, Li-Na [4 ]
机构
[1] Wenzhou Med Coll, Affiliated Hosp 1, Dept Obstet & Gynecol, Wenzhou 325000, Zhejiang, Peoples R China
[2] N Sichuan Med Coll, Inst Med Clin 2, Dept Obstet & Gynecol, Nanchong 637000, Sichuan Prov, Peoples R China
[3] Chongqing Univ, Elect Engn Coll, Minist Educ, Key Lab High Voltage Engn & Elect New Technol, Chongqing 400044, Peoples R China
[4] Sichuan Univ, Affiliated Hosp 2, Dept Obstet & Gynecol, Chengdu 610000, Sichuan Prov, Peoples R China
来源
JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH | 2009年 / 28卷
基金
中国国家自然科学基金;
关键词
STANDARD OPERATING PROCEDURES; IRREVERSIBLE ELECTROPORATION; NONINVASIVE ELECTRODES; REPETITION FREQUENCY; TISSUE ABLATION; TUMORS; BLEOMYCIN; DELIVERY;
D O I
10.1186/1756-9966-28-53
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Patients received electrochemotherapy often associated with unpleasant sensations mainly result from low-frequency electric pulse induced muscle contractions. Increasing the repetition frequency of electric pulse can reduce unpleasant sensations. However, due to the specificity of SPEF, frequency related antitumor efficiency need to be further clarified. The aim of this study was to compare in vitro cytotoxic and in vivo antitumor effect on ovarian cancer cell line SKOV3 by SPEF with different repetition frequencies. Explore potential benefits of using high frequency SPEF in order to be exploitable in electrochemotherapy. Methods: For in vitro experiment, SKOV3 cell suspensions were exposed to SPEF with gradient increased frequencies (1, 60, 1 000, 5 000 Hz) and electric field intensity (50, 100, 150, 200, 250, 300, 350, 400 V/cm) respectively. For in vivo test, SKOV3 subcutaneous implanted tumor in BALB/c nude mice (nu/nu) were exposure to SPEF with gradient increased frequencies (1, 60, 1 000, 5 000 Hz) and fixed electric field intensity (250 V/cm) (7 mice for each frequency and 7 for control). Antitumor efficiency was performed by in vitro cytotoxic assay and in vivo tumor growth inhibition rate, supplemented by histological and TEM observations. Data were analyzed using one-way ANOVA followed by the comparisons of multiple groups. Results: SPEF with a given frequency and appropriate electric field intensity could achieve similar cytotoxicity until reached a plateau of maximum cytotoxicity (approx. 100%). SPEF with different frequencies had significant antitumor efficiency in comparison to the control group (P < 0.05). However, there was no difference in tumor responses among test groups (P > 0.05). Histological and TEM observations demonstrated obvious cell damages in response to SPEF exposure. Furthermore, SPEF with 5 kHz could induce apoptosis under TEM observations both in vitro and in vivo. Conclusion: SPEF with high frequency could also achieve similar antitumor efficiency which can be used to reduce unpleasant sensations in tumor electrical treatment. Our research proposed potential applications of using high frequency SPEF in clinical cancer treatment.
引用
收藏
页数:9
相关论文
共 2 条
  • [1] The effect of high frequency steep pulsed electric fields on in vitro and in vivo antitumor efficiency of ovarian cancer cell line skov3 and potential use in electrochemotherapy
    Xiao-Jun Yang
    Jun Li
    Cai-Xin Sun
    Fei-Yun Zheng
    Li-Na Hu
    Journal of Experimental & Clinical Cancer Research, 28
  • [2] Aurora kinase inhibitor AZD1152 has an additional effect of platinum on a sequential application at the human ovarian cancer cell line SKOV3
    Ma, Yaxi
    Weimer, Joerg
    Fredrik, Regina
    Adam-Klages, Sabine
    Sebens, Susanne
    Caliebe, Amke
    Hilpert, Felix
    Eckmann-Scholz, Christel
    Arnold, Norbert
    Schem, Christian
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2013, 288 (01) : 173 - 182