A bead-based immunogold-silver staining assay on capillary-driven microfluidics

被引:11
|
作者
Pham, Ngoc M. [1 ]
Rusch, Sebastian [2 ,3 ,4 ]
Temiz, Yuksel [5 ]
Lovchik, Robert D. [5 ]
Beck, Hans-Peter [2 ,3 ]
Karlen, Walter [1 ]
Delamarche, Emmanuel [5 ]
机构
[1] ETH, Mobile Hlth Syst Lab, Inst Robot & Intelligent Syst, Dept Hlth Sci & Technol,BAA, Lengghalde 5, CH-8092 Zurich, Switzerland
[2] Swiss Trop & Publ Hlth Inst, Socinstr 57, CH-4051 Basel, Switzerland
[3] Univ Basel, Petersgraben 1, CH-4001 Basel, Switzerland
[4] Kantonsspital Aarau AG, Inst Lab Med, Med Genet, Tellstr 25, CH-5001 Aarau, Switzerland
[5] IBM Res Zurich, Saumerstr 4, CH-8803 Ruschlikon, Switzerland
基金
瑞士国家科学基金会;
关键词
Microfluidics; Silver staining; Immunoassays; Microbeads; IMMUNOSORBENT-ASSAY; GOLD NANOPARTICLES; DETECTION SYSTEMS; RUBELLA-VIRUS; IMMUNOASSAY; BIOMARKERS; ANTIBODIES; CHIP;
D O I
10.1007/s10544-018-0284-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Point-of-care (POC) diagnostics are critically needed for the detection of infectious diseases, particularly in remote settings where accurate and appropriate diagnosis can save lives. However, it is difficult to implement immunoassays, and specifically immunoassays relying on signal amplification using silver staining, into POC diagnostic devices. Effective immobilization of antibodies in such devices is another challenge. Here, we present strategies for immobilizing capture antibodies (cAbs) in capillary-driven microfluidic chips and implementing a gold-catalyzed silver staining reaction. We illustrate these strategies using a species/anti-species immunoassay and the capillary assembly of fluorescent microbeads functionalized with cAbs in "bead lanes", which are engraved in microfluidic chips. The microfluidic chips are fabricated in silicon (Si) and sealed with a dry film resist. Rabbit IgG antibodies in samples are captured on the beads and bound by detection antibodies (dAbs) conjugated to gold nanoparticles. The gold nanoparticles catalyze the formation of a metallic film of silver, which attenuates fluorescence from the beads in an analyte-concentration dependent manner. The performance of these immunoassays was found comparable to that of assays performed in 96 well microtiter plates using "classical" enzyme-linked immunosorbent assay (ELISA). The proof-of-concept method developed here can detect 24.6 ng mL(-1) of rabbit IgG antibodies in PBS within 20 min, in comparison to 17.1 ng mL(-1) of the same antibodies using a similar to 140-min-long ELISA protocol. Furthermore, the concept presented here is flexible and necessitate volumes of samples and reagents in the range of just a few microliters.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Principal component analysis of the Serological response to Plasmodium Falciparum using a Multiplex bead-based assay in Nigeria
    Schultz, Jonathan S.
    Okoli, Mary
    Lee, Scott
    Leonard, Colleen M.
    Sayre, Dean
    Heilig, Charles M.
    Uhomoibhi, Perpetua
    Ogunniyi, Abiodun
    Ndodo, Nnaemeka
    Mba, Nwando
    Abubakar, Ado G.
    Akinmulero, Oluwaseun
    Dawurung, Ayuba B.
    Okoye, Mcpaul
    Iriemenam, Nnaemeka C.
    Plucinski, Mateusz
    Steinhardt, Laura
    Rogier, Eric
    Ihekweazu, Chickwe
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [42] Urinary Cytokines Reflect Renal Inflammation in Acute Tubulointerstitial Nephritis: A Multiplex Bead-Based Assay Assessment
    Martinez Valenzuela, Laura
    Draibe, Juliana
    Bestard, Oriol
    Fulladosa, Xavier
    Gomez-Preciado, Francisco
    Anton, Paula
    Nadal, Ernest
    Jove, Maria
    Maria Cruzado, Josep
    Torras, Juan
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [43] Comparison of anti-CCP autoantibodies measurement by ELISA and a bead-based assay in a large patient cohort
    Harich, Raya
    Roger, Christelle
    Garnier, Lorna
    Bienvenu, Jacques
    Fabien, Nicole
    CLINICAL BIOCHEMISTRY, 2014, 47 (06) : 485 - 488
  • [44] Effect of serum content and diluent selection on assay sensitivity and signal intensity in multiplex bead-based immunoassays
    Pfleger, Christian
    Schloot, Nanette
    ter Veld, Frank
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 329 (1-2) : 214 - 218
  • [45] Borrelia multiplex: a bead-based multiplex assay for the simultaneous detection of Borrelia specific IgG/IgM class antibodies
    Julia Häring
    Max J. Hassenstein
    Matthias Becker
    Julia Ortmann
    Daniel Junker
    André Karch
    Klaus Berger
    Tatia Tchitchagua
    Olaf Leschnik
    Manuela Harries
    Daniela Gornyk
    Pilar Hernández
    Berit Lange
    Stefanie Castell
    Gérard Krause
    Alex Dulovic
    Monika Strengert
    Nicole Schneiderhan-Marra
    BMC Infectious Diseases, 22
  • [46] Borrelia multiplex: a bead-based multiplex assay for the simultaneous detection of Borrelia specific IgG/IgM class antibodies
    Haring, Julia
    Hassenstein, Max J.
    Becker, Matthias
    Ortmann, Julia
    Junker, Daniel
    Karch, Andre
    Berger, Klaus
    Tchitchagua, Tatia
    Leschnik, Olaf
    Harries, Manuela
    Gornyk, Daniela
    Hernandez, Pilar
    Lange, Berit
    Castell, Stefanie
    Krause, Gerard
    Dulovic, Alex
    Strengert, Monika
    Schneiderhan-Marra, Nicole
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [47] Bead-based assay for spatiotemporal gene expression control in cell-free transcription-translation systems
    Finkler, Marc
    Ott, Albrecht
    BIOTECHNIQUES, 2019, 66 (01) : 29 - 33
  • [48] Dual-component gene detection for H7N9 virus - The combination of optical trapping and bead-based fluorescence assay
    Cao, Di
    Li, Cheng-Yu
    Kang, Ya-Feng
    Lin, Yi
    Cui, Ran
    Pang, Dai-Wen
    Tang, Hong-Wu
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 1031 - 1037
  • [49] Detection of Circulating HPV16 DNA as a Biomarker for Cervical Cancer by a Bead-Based HPV Genotyping Assay
    Galati, Luisa
    Combes, Jean-Damien
    Le Calvez-Kelm, Florence
    McKay-Chopin, Sandrine
    Forey, Nathalie
    Ratel, Mathis
    McKay, James
    Waterboer, Tim
    Schroeder, Lea
    Clifford, Gary
    Tommasino, Massimo
    Gheit, Tarik
    MICROBIOLOGY SPECTRUM, 2022, 10 (02):
  • [50] Bubble-driven mixer integrated with a microfluidic bead-based ELISA for rapid bladder cancer biomarker detection
    Lin, Yen-Heng
    Wang, Chia-Chu
    Lei, Kin Fong
    BIOMEDICAL MICRODEVICES, 2014, 16 (02) : 199 - 207