Selective removal of Cu2+ versus Ni2+, Zn2+ and Mn2+ by using a new carrier in a supported liquid membrane

被引:30
|
作者
Molinari, Raffaele [1 ]
Poerio, Teresa [1 ]
Argurio, Pietro [1 ]
机构
[1] Univ Calabria, Dept Chem Engn & Mat, I-87030 Arcavacata Di Rende, Italy
关键词
supported liquid membrane; selective copper(II) transport; selective metal ion recovery; wastewater treatment;
D O I
10.1016/j.memsci.2006.02.002
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A study on transport, kinetic selectivity and stability in SLM operations using a new carrier, the molecule 2-hydroxy-5-dodecylbenzaldehyde (2H5DBA) in kerosene, is described. A simple transport model is derived to evaluate the mass transfer coefficient in the membrane. Finally a comparison with the di-(2-ethylhexyl) phosphoric acid (D2EHPA) carrier in kerosene is made. The SLM system was employed and tested in the removal of Cu2+ from wastewater by using the operating conditions obtained from L-L extraction tests. Studies on the kinetics of copper extraction by using the 2H5DBA showed that complexation reaction is very fast. Transport tests were performed at different carrier concentrations (10%, 30%, 50% (v/v)) showing the improvement of SLM performance with increasing its concentration. Operating the SLM at optimum conditions (50% (v/v) 2H5DBA concentration in kerosene, feed pH 5, strip pH 2.2) final copper concentrations in the feed and strip phases were, respectively, 2.0 and 47.0 mg L-1, starting from 50 mg L-1 in the feed, meaning a significant up-hill transport. The fluxes (J) were calculated by fitting the experimental data of copper concentration in the feed by an exponential equation. They were used to calculate the transport (kinetic) selectivities of Cu2+ SLM separation over Ni2+, Zn2+ and Mn2+, given by the ratio J(0)(Cu)/J(0)(M), where M = Ni, Zn and Mn. The values were 37.4, 48.2 and 42.1, respectively. Transport and stability tests at the optimal carrier concentration by using the 2H5DBA and the D2EHPA in kerosene were carried out to compare them in terms of flux, lifetime and mass transfer coefficients. Experimental data evidenced for 2H5DBA a lower copper flux (8.67 mmol h(-1) m(-2) versus 36.71 mmol h(-1) m(-2)), a lower lifetime (20 h versus 57 h) and lower mass transfer coefficient in the membrane (3.00 x 10(-7) m s(-1) versus 2.00 x 10(-6) m s(-1)) but the selectivity of the separation process can overcome the disadvantages. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:470 / 477
页数:8
相关论文
共 50 条
  • [31] Effect of Zn2+, Cu2+, and Ni2+ ions on the structure of crosslinked segmented polyurethanes
    Kozak, NV
    Kosyanchuk, LF
    Lipatov, YS
    Nizel'skii, YN
    Antonenko, OI
    POLYMER SCIENCE SERIES A, 2000, 42 (12) : 1304 - 1309
  • [32] Selective removal of Mn2+ ions from solutions containing Mn2+, Co2+, and Zn2+ ions using ozone
    Alejo-Guerra, Diana
    Lopez-Valdivieso, Alejandro
    Robledo-Cabrera, Aurora
    MRS ADVANCES, 2024,
  • [33] Synthesis and study of properties of the polyhexamethyleneguanidine complexes with the ions Cu2+, Zn2+, and Ni2+
    V. A. Dobysh
    N. V. Koktysh
    V. A. Tarasevich
    V. E. Agabekov
    V. N. Makatun
    L. I. Antonovskaya
    N. A. Belyasova
    Russian Journal of General Chemistry, 2012, 82 : 1764 - 1769
  • [34] Effect of anions on removing Cu2+, Mn2+ and Zn2+ in electrocoagulation process using aluminum electrodes
    Hanay, Ozge
    Hasar, Halil
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 189 (1-2) : 572 - 576
  • [35] Simultaneous analysis of Co2+, Cu2+, Mn2+, Ni2+ and Zn2+ in the ultraviolet region using 4-(pyridil-2-azo) resorcinol and multivariate calibration
    Saldanha, TCB
    de Araújo, MCU
    Neto, BB
    Chame, HC
    ANALYTICAL LETTERS, 2000, 33 (06) : 1187 - 1202
  • [36] Determination of metal (Bi)sulfide stability constants of Mn2+, Fe2+, Co2+, Ni2+, Cu2+, and Zn2+ by voltammetric methods - Response
    Luther, GW
    Theberge, SM
    Rickard, DT
    Oldroyd, A
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (12) : 3640 - 3641
  • [38] Magnetic, dielectric and microwave properties of M-Ti substituted barium hexaferrites (M=Mn2+, Co2+, Cu2+, Ni2+, Zn2+)
    Sozeri, H.
    Deligoz, H.
    Kavas, H.
    Baykal, A.
    CERAMICS INTERNATIONAL, 2014, 40 (06) : 8645 - 8657
  • [39] Kinetics, equilibrium and mechanism of Cu2+, Ni2+ and Zn2+ ions biosorption using wheat straw
    Gorgievski, Milan
    Bozic, Dragana
    Stankovic, Velizar
    Strbac, Nada
    Serbula, Snezana
    ECOLOGICAL ENGINEERING, 2013, 58 : 113 - 122
  • [40] AMPEROMETRIC TITRATION OF ZN2+ NI2+ + MN2+ WITH 8-HYDROXYQUINOLINE BY AC POLAROGRAPHY
    GUPTA, SL
    SHARMA, SK
    JAITLY, JN
    INDIAN JOURNAL OF CHEMISTRY, 1966, 4 (04): : 166 - &