Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession

被引:88
作者
Thiele, H
Paetsch, I
Schnackenburg, B
Bornstedt, A
Grebe, O
Wellnhofer, E
Schuler, G
Fleck, E
Nagel, E
机构
[1] Humboldt Univ, German Heart Inst, Clin Internal Med Cardiol, D-13353 Berlin, Germany
[2] Univ Leipzig, Ctr Heart, Clin Internal Med Cardiol, Leipzig, Germany
[3] Philips Med Syst, Hamburg, Germany
[4] Univ Ulm, Clin Internal Med 2, D-89069 Ulm, Germany
关键词
magnetic resonance; steady-state free precession; left ventricular function; left ventricular volumes; image quality;
D O I
10.1081/JCMR-120013298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine whether steady-state free precession (SSFP) could improve accuracy of geometric models for evaluation of left ventricular (LV)function in comparison to turbo gradient echo (TGrE) and thereby reduce the acquisition and post-processing times, which are commonly long by use of the Simpson's Rule. In 25 subjects, cine loops of the complete heart in short and horizontal long-axis planes were acquired using TGrE (TR/TE/flip = 5.0/1.9/25) compared with SSFP (TR/TE/flip = 3.2/1.2/60). LV volumes and EF were measured with various geometric models for TGrE and SSFP. With three-dimensional data, the LV volumes were higher and the resulting EF lower for SSFP in contrast to TGrE (51 +/- 15% vs. 57 +/- 15%, p < 0.001). With SSFP, various geometric models yielded good to excellent correlations for LV volumes and LVEF compared to volumetric data (r = 0.94 - 0.98, mean relative difference 7.0-11.4%). In contrast, correlations were low using biplane or single-plane ellipsoid models in TGrE (r = 0.71 - 0.75, mean relative difference 15.9-30.2%). A new combined geometric model, taking all three dimensions into account, yielded the highest accuracy for SSFP in comparison to volumetric data (r = 0.99, mean relative difference 4.7%). Geometric models for assessment of LV volumes and EF yield higher accuracy and reproducibility by use of the SSFP sequence than by standard TGrE. This may increase clinical utility of magnetic resonance by shorter acquisition and processing times.
引用
收藏
页码:327 / 339
页数:13
相关论文
共 33 条
  • [1] AUTOMATED MYOCARDIAL EDGE-DETECTION FROM BREATH-HOLD CINE-MR IMAGES - EVALUATION OF LEFT-VENTRICULAR VOLUMES AND MASS
    BALDY, C
    DOUEK, P
    CROISILLE, P
    MAGNIN, IE
    REVEL, D
    AMIEL, M
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (04) : 589 - 598
  • [2] MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    Barkhausen, J
    Ruehm, SG
    Goyen, M
    Buck, T
    Laub, G
    Debatin, JF
    [J]. RADIOLOGY, 2001, 219 (01) : 264 - 269
  • [3] Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance
    Bellenger, NG
    Davies, LC
    Francis, JM
    Coats, AJS
    Pennell, DJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) : 271 - 278
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] SERIAL LONG-TERM ASSESSMENT OF THE NATURAL-HISTORY OF ASYMPTOMATIC PATIENTS WITH CHRONIC AORTIC REGURGITATION AND NORMAL LEFT-VENTRICULAR SYSTOLIC FUNCTION
    BONOW, RO
    LAKATOS, E
    MARON, BJ
    EPSTEIN, SE
    [J]. CIRCULATION, 1991, 84 (04) : 1625 - 1635
  • [6] Buck T, 1997, CIRCULATION, V96, P4286
  • [7] Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    Carr, JC
    Simonetti, O
    Bundy, J
    Li, DB
    Pereles, S
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (03) : 828 - 834
  • [8] USE OF BIPLANE CINEFLUOROGRAPHY FOR MEASUREMENT OF VENTRICULAR VOLUME
    CHAPMAN, CB
    BAKER, O
    REYNOLDS, J
    BONTE, FJ
    [J]. CIRCULATION, 1958, 18 (06) : 1105 - 1117
  • [9] Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging
    Chuang, ML
    Hibberd, MG
    Salton, CJ
    Beaudin, RA
    Riley, MF
    Parker, RA
    Douglas, PS
    Manning, WJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 477 - 484
  • [10] NITRATES VERSUS ANGIOTENSIN-CONVERTING ENZYME-INHIBITORS FOR CONGESTIVE-HEART-FAILURE
    COHN, JN
    PARISI, AF
    BABB, J
    FENSTER, P
    WEISBERGER, CL
    SMITH, TW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (08) : C21 - C26