Role of ultrasound surveillance of transjugular intrahepatic portosystemic shunts in the covered stent era

被引:30
作者
Carr, Caitlin E. [1 ]
Tuite, Catherine M. [1 ]
Soulen, Michael C. [1 ]
Shlansky-Goldberg, Richard D. [1 ]
Clark, Timothy W. I. [1 ]
Mondschein, Jeffrey I. [1 ]
Kwak, Andrew [1 ]
Patel, Aalpen A. [1 ]
Coleman, Beverly G. [1 ]
Trerotola, Scott O. [1 ]
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Div Intervent Radiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1097/01.RVI.0000231951.47931.82
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess ultrasound (US) surveillance of expanded polytetrafluoroethylene (ePTFE)-covered stents in transjugular intrahepatic portosystemic shunts (TIPS). MATERIALS AND METHODS: Procedural data, including stent size and portosystemic gradients (PSG) before and after creation of TIPS, were obtained retrospectively in 55 patients (33 men, 22 women). Chart review provided clinical information, including etiology of liver disease, indication for TIPS creation, and Child-Pugh class. Radiology reports provided US venography data and pathology reports confirmed shunt status in transplant recipients. Patients had baseline US examinations 3-7 days after TIPS creation with scheduled follow-up at 1, 3, 6, and 12 months after the procedure. Clinical and radiology reports were compared to evaluate US surveillance of Viatorr stents. RESULTS: One hundred fifty-nine US examinations were performed on 52 patients, for an average 3 '.1 studies per patient (range, 1-7) over a mean follow-up duration of 173 days (range, 0-1,013 d). Sixty-four US studies (40%) were baseline studies, 88 studies (55%) were routine follow-up studies, and seven (4%) were interval studies. US predicted TIPS abnormalities in 30 of 159 studies (19%); venography followed 15 of 30 abnormal US findings (50%) and clinical examinations complemented 10 of 15 venograms (67%). Venography and US were concordant in eight of 15 paired studies (53%); clinical examinations, when conducted, accurately predicted shunt status in all but one case. US findings changed management in six of 159 studies (4%): five of six (83%) were baseline evaluations and the other one (17%) was a routine follow-up examination. A total of five baseline US examinations (8%) and one surveillance examination (1%) altered patient management. CONCLUSIONS: A single US examination after a TIPS procedure to confirm immediate function may be valuable, but routine US is not effective for long-term surveillance of ePTFE-covered stents.
引用
收藏
页码:1297 / 1305
页数:9
相关论文
共 39 条
  • [1] Doppler ultrasound for TIPS:: does it work?
    Benito, A
    Bilbao, J
    Hernández, T
    Martinez-Cuesta, A
    Larrache, J
    González, I
    Vivas, I
    [J]. ABDOMINAL IMAGING, 2004, 29 (01): : 45 - 52
  • [2] ePTFE-covered stent-grafts for revision of obstructed transjugular intrahepatic portosystemic shunt
    Cejna, M
    Peck-Radosavljevic, M
    Thurnher, S
    Schoder, M
    Rand, T
    Angermayr, B
    Lammer, J
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 25 (05) : 365 - 372
  • [3] Results of a retrospective multicenter trial of the Viatorr expanded polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation
    Charon, JPM
    Alaeddin, FH
    Pimpalwar, SA
    Fay, DM
    Olliff, SP
    Jackson, RW
    Edwards, RD
    Robertson, IR
    Rose, JD
    Moss, JG
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (11) : 1219 - 1230
  • [4] TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT - US ASSESSMENT WITH MAXIMUM FLOW VELOCITY
    CHONG, WK
    MALISCH, TA
    MAZER, MJ
    LIND, CD
    WORRELL, JA
    RICHARDS, WO
    [J]. RADIOLOGY, 1993, 189 (03) : 789 - 793
  • [5] The effect of initial shunt outflow position on patency of transjugular intrahepatic portosystemic shunts
    Clark, TWI
    Agarwal, R
    Haskal, ZJ
    Stavropoulos, SW
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (02) : 147 - 152
  • [6] FORMATION OF INTRAHEPATIC PORTOSYSTEMIC SHUNTS USING A BALLOON DILATATION CATHETER - PRELIMINARY CLINICAL-EXPERIENCE
    COLAPINTO, RF
    STRONELL, RD
    GILDINER, M
    RITCHIE, AC
    LANGER, B
    TAYLOR, BR
    BLENDIS, LM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (04) : 709 - 714
  • [7] MULTICENTER INVESTIGATION OF THE ROLE OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT IN MANAGEMENT OF PORTAL-HYPERTENSION
    COLDWELL, DM
    RING, EJ
    REES, CR
    ZEMEL, G
    DARCY, MD
    HASKAL, ZJ
    MCKUSICK, MA
    GREENFIELD, AJ
    [J]. RADIOLOGY, 1995, 196 (02) : 335 - 340
  • [8] DELEVE L, 1998, HEPATOLOGY, P1433
  • [9] DETECTION OF TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT DYSFUNCTION - VALUE OF DUPLEX-DOPPLER SONOGRAPHY
    DODD, GD
    ZAJKO, AB
    ORONS, PD
    MARTIN, MS
    EICHNER, LS
    SANTAGUIDA, LA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) : 1119 - 1124
  • [10] Transjugular intrahepatic portosystemic shunts: Accuracy of Doppler US in determination of patency and detection of stenoses
    Feldstein, VA
    Patel, MD
    LaBerge, JM
    [J]. RADIOLOGY, 1996, 201 (01) : 141 - 147