Tribo-corrosion characterization of NiTiCu alloy for bio-implant applications

被引:15
作者
Sharma, Neeraj [1 ,5 ]
Singh, Gurpreet [2 ]
Hegab, Hussien [3 ]
Mia, Mozammel [4 ]
Batra, Neel Kamal [1 ]
机构
[1] Maharishi Markandeshwar Deemed Be Univ, Dept Mech Engn, Mullana 133207, India
[2] Amity Univ, Amity Inst Technol, Noida 133207, India
[3] Cairo Univ, Mech Design & Prod Engn Dept, Giza 12163, Egypt
[4] Ahsanullah Univ Sci & Technol, Mech & Prod Engn, 141-142 Love Rd, Dhaka 1208, Bangladesh
[5] Univ Johannesburg, Dept Mech & Ind Engn Technol, ZA-2006 Johannesburg, South Africa
关键词
bio-implant; micro-hardness; NiTiCu; tribo-corrosion; SHAPE-MEMORY ALLOY; TRIBOLOGICAL BEHAVIOR; TRIBOCORROSION; RESISTANCE; BONE; WEAR;
D O I
10.1088/2053-1591/ab2d95
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the current scenario of medical research, NiTi based smart alloys gaining importance due to the pioneer quality of biocompatibility, wear and corrosion resistance. In the present research, copper particles were blended with the nickel and titanium powder for 8 hours in high energy ball mill for uniform mixing. Specimens were fabricated using powder metallurgy at different compaction pressures. During the sintering process, the binder gets evaporated which makes it porous and suitable for biomedical implants. The testing was carried out to improve the corrosion and wear resistance of NiTi alloy under load-bearing biomedical applications. The addition of copper increases the wear and corrosion resistance of NiTi alloy. The experiments were conducted on pin-on-disk tribometer in the presence of simulated body fluid (SBF) at the temperature of 37 +/- 1 degrees C. The test conditions were maintained according to the simulated hip joint. It was observed that the wear resistance of NiTi alloy increases slightly with the addition of copper particles up to certain percentage. The behaviour of the material changes after copper addition in the presence of SBF. Furthermore, the copper particles were blended with other particles to investigate the consequences on the tribological and corrosion characteristics of the developed materials. The corrosion rate increases when the copper contents were more than 5% due to decrease in the E-corrosion (-0.19), but after increase the copper content from 5% an increase in E-corrosion (-0.17) was observed. The copper content should be less than 5% to avoid pitting in the material; otherwise, it decreases the anti-pitting ability of NiTi alloy. The size of wear debris also decreases with the addition of copper up to 5%. After that, an increase in the size of wear debris was observed which makes it unsuitable for biomedical implants.
引用
收藏
页数:15
相关论文
共 40 条
[1]   Tribological behavior of NiTi alloy in martensitic and austenitic states [J].
Abedini, M. ;
Ghasemi, H. M. ;
Ahmadabadi, M. Nili .
MATERIALS & DESIGN, 2009, 30 (10) :4493-4497
[2]   Effect of cobalt addition on the corrosion behavior of near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies [J].
Alqarni, Nawal D. ;
Wysocka, Joanna ;
El-Bagoury, Nader ;
Ryl, Jacek ;
Amin, Mohammed A. ;
Boukherroub, Rabah .
RSC ADVANCES, 2018, 8 (34) :19289-19300
[3]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[4]   Biocompatibility tests with fibroblasts of CaO rich calcium silicate glasses [J].
Catauro, M ;
Raucci, MG ;
Continenza, MA ;
Marotta, A .
JOURNAL OF MATERIALS SCIENCE, 2004, 39 (01) :373-375
[5]   Assessing the biocompatibility of NiTi shape memory alloys used for medical applications [J].
Es-Souni, M ;
Es-Souni, M ;
Fischer-Brandies, H .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) :557-567
[6]   An overview of NiTi shape memory alloy: Corrosion resistance and antibacterial inhibition for dental application [J].
Fadlallah, Sahar A. ;
El-Bagoury, Nader ;
El-Rab, Sanaa M. F. Gad ;
Ahmed, Rasha A. ;
El-Ousamii, Ghaida .
JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 583 :455-464
[7]   Corrosion behaviour of NiTi alloy [J].
Figueira, N. ;
Silva, T. M. ;
Carmezim, M. J. ;
Fernandes, J. C. S. .
ELECTROCHIMICA ACTA, 2009, 54 (03) :921-926
[8]   Torsional properties of Ni-Ti orthodontic archwires [J].
Filleul, MP ;
Constant, S .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1999, 273 :775-779
[9]   Corrosion-wear of passivating materials in sliding contacts based on a concept of active wear track area [J].
García, I ;
Drees, D ;
Celis, JP .
WEAR, 2001, 249 (5-6) :452-460
[10]  
Gil FJ, 1999, J BIOMED MATER RES, V48, P682, DOI 10.1002/(SICI)1097-4636(1999)48:5<682::AID-JBM12>3.0.CO