Near Infrared Spectroscopy for Rapid Determination of Mankin Score Components: A Potential Tool for Quantitative Characterization of Articular Cartilage at Surgery

被引:26
作者
Afara, Isaac Oluwaseun [1 ,2 ]
Prasadam, Indira [2 ]
Moody, Hayley [1 ,2 ]
Crawford, Ross [2 ,3 ]
Xiao, Yin [1 ,2 ]
Oloyede, Adekunle [1 ,2 ]
机构
[1] Queensland Univ Technol, Fac Sci & Engn, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld 4001, Australia
[3] Prince Charles Hosp, Brisbane, Qld 4032, Australia
基金
英国医学研究理事会;
关键词
OSTEOARTHRITIS; PARAMETERS; MORPHOLOGY; SPECTRA;
D O I
10.1016/j.arthro.2014.04.097
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to demonstrate the potential of near infrared (NIR) spectroscopy for characterizing the health and degenerative state of articular cartilage based on the components of the Mankin score. Methods: Three models of osteoarthritic degeneration induced in laboratory rats by anterior cruciate ligament (ACL) transection, meniscectomy (MSX), and intra-articular injection of monoiodoacetate (1 mg) (MIA) were used in this study. Degeneration was induced in the right knee joint; each model group consisted of 12 rats (N = 36). After 8 weeks, the animals were euthanized and knee joints were collected. A custom-made diffuse reflectance NIR probe of 5-mm diameter was placed on the tibial and femoral surfaces, and spectral data were acquired from each specimen in the wave number range of 4,000 to 12,500 cm(-1). After spectral data acquisition, the specimens were fixed and safranin O staining (SOS) was performed to assess disease severity based on the Mankin scoring system. Using multivariate statistical analysis, with spectral preprocessing and wavelength selection technique, the spectral data were then correlated to the structural integrity (SI), cellularity (CEL), and matrix staining (SOS) components of the Mankin score for all the samples tested. Results: ACL models showed mild cartilage degeneration, MSX models had moderate degeneration, and MIA models showed severe cartilage degenerative changes both morphologically and histologically. Our results reveal significant linear correlations between the NIR absorption spectra and SI (R-2 = 94.78%), CEL (R-2 = 88.03%), and SOS (R-2 = 96.39%) parameters of all samples in the models. In addition, clustering of the samples according to their level of degeneration, with respect to the Mankin components, was also observed. Conclusions: NIR spectroscopic probing of articular cartilage can potentially provide critical information about the health of articular cartilage matrix in early and advanced stages of osteoarthritis (OA).
引用
收藏
页码:1146 / 1155
页数:10
相关论文
共 25 条
[1]   Application of near infrared (NIR) spectroscopy for determining the thickness of articular cartilage [J].
Afara, I. ;
Singh, S. ;
Oloyede, A. .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) :88-95
[2]   Non-destructive evaluation of articular cartilage defects using near-infrared (NIR) spectroscopy in osteoarthritic rat models and its direct relation to Mankin score [J].
Afara, I. ;
Prasadam, I. ;
Crawford, R. ;
Xiao, Y. ;
Oloyede, A. .
OSTEOARTHRITIS AND CARTILAGE, 2012, 20 (11) :1367-1373
[3]   Load-unloading response of intact and artificially degraded articular cartilage correlated with near infrared (NIR) absorption spectra [J].
Afara, I. O. ;
Singh, S. ;
Oloyede, A. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 20 :249-258
[4]   Near infrared (NIR) absorption spectra correlates with subchondral bone micro-CT parameters in osteoarthritic rat models [J].
Afara, Isaac Oluwaseun ;
Prasadam, Indira ;
Crawford, Ross ;
Xiao, Yin ;
Oloyede, Adekunle .
BONE, 2013, 53 (02) :350-357
[5]  
Bjorsvik H.R., 2001, Handbook of Near-Infrared analysis, P185
[6]   Derivative preprocessing and optimal corrections for baseline drift in multivariate calibration [J].
Brown, CD ;
Vega-Montoto, L ;
Wentzell, PD .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1055-1068
[7]  
Cohen J., 1988, Statistical power analysis for the behavioral sciences, VSecond
[8]   APPLICATION OF PRINCIPAL COMPONENT ANALYSIS ON NIR SPECTRAL COLLECTION AFTER ELIMINATION OF INTERFERENCE BY A LEAST-SQUARES PROCEDURE [J].
DEVAUX, MF ;
BERTRAND, D ;
ROBERT, P ;
QANNARI, M .
APPLIED SPECTROSCOPY, 1988, 42 (06) :1020-1023
[9]   Fiber-optic Raman spectroscopy of joint tissues [J].
Esmonde-White, Karen A. ;
Esmonde-White, Francis W. L. ;
Morris, Michael D. ;
Roessler, Blake J. .
ANALYST, 2011, 136 (08) :1675-1685
[10]   NONINVASIVE INVIVO NEAR-INFRARED OPTICAL MEASUREMENT OF THE PENETRATION DEPTH IN THE NEONATAL HEAD [J].
FARIS, F ;
THORNILEY, M ;
WICKRAMASINGHE, Y ;
HOUSTON, R ;
ROLFE, P ;
LIVERA, N ;
SPENCER, A .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 (04) :353-358