Renal artery stenosis: Endovascular flow wire study for validation of Doppler US

被引:41
作者
vanderHulst, VPM
vanBaalen, J
Kool, LS
vanBockel, JH
vanErkel, AR
Ilgun, J
Pattynama, PMT
机构
[1] UNIV LEIDEN HOSP, DEPT VASC SURG, 2300 RC LEIDEN, NETHERLANDS
[2] UNIV LEIDEN HOSP, MED DECIS MAKING UNIT, 2300 RC LEIDEN, NETHERLANDS
关键词
renal arteries; flow dynamics; stenosis or obstruction; ultrasound; (US); Doppler studies; intravascular;
D O I
10.1148/radiology.200.1.8657905
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the accuracy of proximal and peripheral Doppler parameters for detection of renal artery stenosis (RAS). MATERIALS AND METHODS: The authors obtained absolute velocities and peripheral Doppler waveforms in 16 stenotic and 14 normal renal arteries by using a 0.45-mm endovascular now wire. Hemodynamically significant stenosis was established by measuring transstenotic invasive pressure gradients, with a 10 mm Hg or greater pressure drop indicating RAS. Accuracy of the Doppler parameters and of digital subtraction angiographic (DSA) results were compared by using receiver operating characteristic analysis. RESULTS: Measurements of absolute velocities at the site of the stenosis (maximal peak systolic velocity [PSVmax], PSV ratio, renal artery-to-aortic PVS ratio) showed high accuracy for diagnosis of RAS similar to that of DSA (areas under the ROC curve were 0.96, 0.97, 0.93, respectively). The distal intrarenal Doppler indexes (notably loss of early systolic peak, acceleration, acceleration time, pulsatility index, and resistive index) did not show statistically significant correlation with RAS. CONCLUSION Doppler measurements in the main renal artery correlate well with RAS. The intrarenal Doppler spectrum, however, has no diagnostic value. The authors conclude that duplex Doppler US is not a suitable screening test for RAS.
引用
收藏
页码:165 / 168
页数:4
相关论文
共 23 条
[1]   NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY [J].
AVASTHI, PS ;
VOYLES, WF ;
GREENE, ER .
KIDNEY INTERNATIONAL, 1984, 25 (05) :824-829
[2]   RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS [J].
BERLAND, LL ;
KOSLIN, DB ;
ROUTH, WD ;
KELLER, FS .
RADIOLOGY, 1990, 174 (02) :421-423
[3]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[4]   RENAL-ARTERY STENOSIS - EVALUATION WITH COLOR DOPPLER FLOW IMAGING [J].
DESBERG, AL ;
PAUSHTER, DM ;
LAMMERT, GK ;
HALE, JC ;
TROY, RB ;
NOVICK, AC ;
NALLY, JV ;
WELTEVREDEN, AM .
RADIOLOGY, 1990, 177 (03) :749-753
[5]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[6]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[7]   QUANTITATIVE ANALYSIS OF OCCLUSIVE PERIPHERAL ARTERIAL DISEASE BY A NON-INTRUSIVE ULTRASONIC TECHNIQUE [J].
GOSLING, RG ;
DUNBAR, G ;
KING, DH ;
NEWMAN, DL ;
SIDE, CD ;
WOODCOCK, JP ;
FITZGERALD, DE ;
KEATES, JS ;
MACMILLAN, D .
ANGIOLOGY, 1971, 22 (01) :52-+
[8]   EFFICACY OF ECHO-DOPPLER EXAMINATION FOR THE EVALUATION OF RENOVASCULAR DISEASE [J].
HANDA, N ;
FUKUNAGA, R ;
ETANI, H ;
YONEDA, S ;
KIMURA, K ;
KAMADA, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (01) :1-5
[9]   RENAL DUPLEX SONOGRAPHY - EVALUATION OF CLINICAL UTILITY [J].
HANSEN, KJ ;
TRIBBLE, RW ;
REAVIS, SW ;
CANZANELLO, VJ ;
CRAVEN, TE ;
PLONK, GW ;
DEAN, RH .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) :227-236
[10]   ROLE OF DUPLEX SCANNING FOR THE DETECTION OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE [J].
HOFFMANN, U ;
EDWARDS, JM ;
CARTER, S ;
GOLDMAN, ML ;
HARLEY, JD ;
ZACCARDI, MJ ;
STRANDNESS, DE .
KIDNEY INTERNATIONAL, 1991, 39 (06) :1232-1239