On the coupling of hydride generation (HG) with flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) for determination of traces of As, Bi, Hg, Sb and Se by optical emission spectrometry (OES)

被引:27
作者
Gorska, Monika [1 ]
Greda, Krzysztof [1 ]
Pohl, Pawel [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Chem, Div Analyt Chem & Chem Met, Wybrzeze Stanislawa Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
Atmospheric pressure glow discharge; Flowing liquid anode; Solution anode glow discharge; Cold vapor generation; Hydride generation; Miniaturized plasma; Optical emission spectrometry; CHEMICAL-VAPOR GENERATION; ATOMIC-ABSORPTION; EXCITATION SOURCE; VOLATILE CADMIUM; CATHODE; AG; CD; JET; ZN; PB;
D O I
10.1016/j.talanta.2020.121510
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel atmospheric pressure glow discharge (APGD) microplasma system, sustained between a miniaturized flowing liquid anode (FLA) and a He jet nozzle cathode, was combined with a hydride generation (HG) technique to improve the determination performance of As, Bi, Hg, Sb, and Se with the aid of optical emission spectrometry (OES). The discharge current, the He flow rate, and the concentrations of HCl and NaBH4 were considered to affect both the HG reaction and the excitation conditions in the discharge, thus they were thoroughly studied. Under the optimized conditions, the detections limits (LODs), assessed on the basis of the 3 sigma criterion, reached 1.7, 0.85, 0.04, 0.51, and 2.9 mu g L-1 for As, Bi, Hg, Sb, and Se, respectively. The HG and transport efficiency for these elements was evaluated to be 88-100%, which is notably better, as compared to their transport efficiency in the conventional FLA-APGD system, without the HG technique. This yielded an improvement of the LODs achievable in this system and, simultaneously, enabled to determine As, Sb, and Se at a level, which is unob-tainable with the use of the FLA-APGD system alone. The proposed methodology was then successfully applied for a quantitative determination of the examined elements in wastewater (ERM-CA713) and spiked water samples. The recoveries of the elements added to these waters (at the maximum acceptable levels in drinking water set by the U.S. Environmental Protection Agency) ranged between 81 and 104%, confirming the excellent accuracy, usefulness, and reliability of the developed HG-FLA-APGD technique.
引用
收藏
页数:10
相关论文
共 22 条
[21]   Simultaneous determination of hydride (As, Bi, Ge, Sb, Se, Sn) and Hg and non-hydride forming (Ca, Fe, Mg, Mn, Zn) elements in sonicate slurries of analytical samples by microwave induced plasma optical emission spectrometry with dual-mode sample introduction system [J].
Matusiewicz, Henryk ;
Slachcinski, Mariusz .
MICROCHEMICAL JOURNAL, 2007, 86 (01) :102-111
[22]   Possibilities and limits of the simultaneous determination of As, Bi, Ge, Sb, Se, and Sn by flow injection-hydride generation-inductively coupled plasma-time-of-flight mass spectrometry (FI-HG-ICP-TOFMS) [J].
Abrankó, L ;
Stefánka, Z ;
Fodor, P .
ANALYTICA CHIMICA ACTA, 2003, 493 (01) :13-21