Experimental study on the direct contact condensation of the steam-air mixture in subcooled water flow in a rectangular channel

被引:24
|
作者
Yang Xiaoping [1 ]
Chong Daotong [2 ]
Liu Jiping [1 ]
Zong Xiao [1 ]
Yan Junjie [2 ]
机构
[1] Xi An Jiao Tong Univ, MOE Key Lab Thermal Fluid Sci & Engn, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
美国国家科学基金会;
关键词
Direct contact condensation; Steam-air mixture; Flow patterns; Temperature distributions; Pressure distributions; Heat transfer; JET INJECTOR; PERFORMANCE; PENETRATION; PUMP;
D O I
10.1016/j.ijheatmasstransfer.2015.04.104
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was performed to investigate the direct contact condensation (DCC) of steam-air mixture in subcooled water flow in a rectangular channel. The main inlet parameters including steam mass flux, water mass flux and water temperature were tested at 150-550 kg/(m(2) s), 6-14 x 10(3) kg/ (m2 s) and 30 degrees C, respectively. The air mass fraction was in the range of 0%-2%. Four different flow patterns for pure steam in subcooled water flow were filmed by a high speed camera. The effect of air on these four flow patterns was investigated by introducing air into steam. The pressure and temperatures on the wall of channel were measured without destroying the flow field. The results indicated that with the present of air, the direct contact condensation was hindered, the interface area enlarged, the mixture layer thickened and plenty of small bubbles gathered in the channel. The air had greater influence on the phase interface area of unstable flow patterns than that of stable flow patterns. This phenomenon could not only be observed in the pictures of flow patterns, but also be reflected in the bottom wall pressure and temperature distributions. The average heat transfer coefficient for pure steam jet in subcooled water flow was in the range of 3.92-6.81 MW/(m(2) degrees C). Since air mass fraction increased, the average heat transfer coefficient decreased. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
  • [41] PREDICTION OF HEAT-TRANSFER BY DIRECT CONTACT CONDENSATION AT A STEAM SUBCOOLED WATER INTERFACE
    MURATA, A
    HIHARA, E
    SAITO, T
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (01) : 101 - 109
  • [42] An investigation of direct condensation of steam jet in subcooled water
    Chun, MH
    Kim, YS
    Park, JW
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1996, 23 (07) : 947 - 958
  • [43] Experimental study of steam-air condensation over a vertically longitudinal finned tube
    Tong, Pan
    Fan, Guangming
    Sun, Zhongning
    Ding, Ming
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 89 : 1230 - 1238
  • [44] Numerical investigation of heat transfer in direct contact condensation of steam to subcooled water spray
    Ding, Hengtao
    Luo, Yiqing
    Yuan, Xigang
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 140 : 52 - 63
  • [45] Thermal hydraulic characteristics of unstable bubbling of direct contact condensation of steam in subcooled water
    Yang, Se Ro
    Seo, Joseph
    Hassan, Yassin A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 138 : 580 - 596
  • [46] Interfacial characteristics of steam jet condensation in subcooled water pipe flow - An experimental and numerical study
    Xu, Qiang
    Liu, Chenying
    Liu, Qimeng
    Zhu, Yongshuai
    Zhou, Haozu
    Guo, Liejin
    CHEMICAL ENGINEERING SCIENCE, 2022, 251
  • [47] Experimental study on sonic steam jet condensation in quiescent subcooled water
    Wu, Xin-Zhuang
    Yan, Jun-Jie
    Li, Wen-Jun
    Pan, Dong-Dong
    Chong, Dao-Tong
    CHEMICAL ENGINEERING SCIENCE, 2009, 64 (23) : 5002 - 5012
  • [48] Experimental study of steam and steam-air mixture condensation over vertical chrome-plated tube and polished tube exterior surface
    Niu, Zesheng
    Cheng, Jie
    Li, Wei
    Fan, Guangming
    NUCLEAR ENGINEERING AND DESIGN, 2021, 373
  • [49] Modeling steam condensation from steam-air mixture in the inclined tubes of an air-cooled condenser
    Artemov V.I.
    Minko K.B.
    Yan'Kov G.G.
    Thermal Engineering, 2014, 61 (1) : 30 - 40
  • [50] LAMINAR FILM CONDENSATION FROM A STEAM-AIR MIXTURE UNDERGOING FORCED FLOW DOWN A VERTICAL SURFACE
    DENNY, VE
    MILLS, AF
    JUSIONIS, VJ
    JOURNAL OF HEAT TRANSFER, 1971, 93 (03): : 297 - &