Static Meters for the Reactive Energy in the Presence of Harmonics: An Experimental Metrological Characterization

被引:30
作者
Cataliotti, Antonio [1 ]
Cosentino, Valentina [1 ]
Nuccio, Salvatore [1 ]
机构
[1] Univ Palermo, Dept Elect Elect & Telecommun Engn DIEET, I-90128 Palermo, Italy
关键词
Energy measurements; power systems harmonics; reactive power; reference standard meters; static meters;
D O I
10.1109/TIM.2009.2015633
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several experimental tests.
引用
收藏
页码:2574 / 2579
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 2003, 6205211 EN
[2]  
[Anonymous], 2003, 6205321 EN
[3]   A novel approach based on nonactive power for the identification of disturbing loads in power systems [J].
Barbaro, Pietro Vincenzo ;
Cataliotti, Antonio ;
Cosentino, Valentina ;
Nuccio, Salvatore .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (03) :1782-1789
[4]  
CATALIOTTI A, 2007, P IMTC WARS POL MAY
[5]   INDUCTION VARHOUR AND SOLID-STATE VARHOUR METERS PERFORMANCES ON NONLINEAR LOADS [J].
COX, MD ;
WILLIAMS, TB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (04) :1678-1686
[6]  
Czarnecki LS, 2000, ELECTR ENG, V82, P119, DOI 10.1007/s002020050002
[7]   POWERS IN NONSINUSOIDAL SITUATIONS - A REVIEW OF DEFINITIONS AND PHYSICAL MEANING [J].
EMANUEL, AE .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (03) :1377-1389
[8]  
Ferreira Rodrigo Lopes, 1998, Diversity & Distributions, V4, P235
[9]   EVALUATION OF REACTIVE POWER METERS IN THE PRESENCE OF HIGH HARMONIC DISTORTION [J].
FILIPSKI, PS ;
LABAJ, PW .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (04) :1793-1799
[10]   A new methodological approach to quality assurance of energy meters under nonsinusoidal conditions [J].
Gallo, Daniele ;
Landi, Carmine ;
Pasquino, Nicola ;
Polese, Nello .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (05) :1694-1702