Polypropylene hollow fiber oxygenators: Effect of the sorption of perfluoropolyethers

被引:3
作者
Cassiola, F
Kiyohara, PK
Joekes, I [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, Dept Quim Fis, BR-13083970 Campinas, SP, Brazil
[2] USP, Inst Fis, Lab Microscopia Electron, Dept Fis Geral, Sao Paulo, Brazil
关键词
microporous hollow fibers; blood oxygenator; perfluorocarbons; gas permeation;
D O I
10.1046/j.1525-1594.2000.06539.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The introduction of microporous polypropylene hollow fibers in recent years has brought considerable advances to blood oxygenators. However, lifetime and assembly problems are still unresolved. In this work we tried to rate the oxygen permeation velocity by turning the fibers more hydrophobic through the sorption of a perfluorocarbon. Fomblin HC/25, a perfluoropolyether, is well known for its low surface tension and high affinity for oxygen. Celgard X10, X20, and X30 commercial hollow fibers were tested. The hollow fibers showed high affinity for the perfluoropolyether; swelling was clearly shown. A new system for the measurement of oxygen permeation velocity was developed. The oxygen transport velocity was not significantly changed after sorption. The Celgard microporous hollow fibers impregnated with perfluoropolyether showed no water permeation after 2 months of use, reducing one of the most serious problems in the lifetime of these types of fibers.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 14 条
  • [1] Cheng B T, 1995, ASAIO J, V41, P863
  • [2] THE EFFECT OF SHELL SIDE HYDRODYNAMICS ON THE PERFORMANCE OF AXIAL-FLOW HOLLOW-FIBER MODULES
    COSTELLO, MJ
    FANE, AG
    HOGAN, PA
    SCHOFIELD, RW
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1993, 80 (1-3) : 1 - 11
  • [3] Gaylor John D. S., 1994, Perfusion, V9, P173, DOI 10.1177/026765919400900304
  • [4] A NEW MULTILAYERED COMPOSITE HOLLOW FIBER MEMBRANE FOR ARTIFICIAL LUNG
    KAMO, J
    UCHIDA, M
    HIRAI, T
    YOSIDA, H
    KAMADA, K
    TAKEMURA, T
    [J]. ARTIFICIAL ORGANS, 1990, 14 (05) : 369 - 372
  • [5] METHODS FOR ESTIMATION OF VAPOR-PRESSURES AND OXYGEN SOLUBILITIES OF FLUOROCHEMICALS FOR POSSIBLE APPLICATION IN ARTIFICIAL BLOOD FORMULATIONS
    LAWSON, DD
    MOACANIN, J
    SCHERER, KV
    TERRANOVA, TF
    INGHAM, JD
    [J]. JOURNAL OF FLUORINE CHEMISTRY, 1978, 12 (03) : 221 - 236
  • [6] Gas permeability of hollow fiber membranes in a gas-liquid system
    Lund, LW
    Federspiel, WJ
    Hattler, BG
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1996, 117 (1-2) : 207 - 219
  • [7] Montoya J P, 1992, ASAIO J, V38, pM399, DOI 10.1097/00002480-199207000-00064
  • [8] PANTINI G, 1988, TECNOLOGIE CHEM, V8, P44
  • [9] QI Z, 1985, Journal of Membrane Science, V23, P333, DOI 10.1016/S0376-7388(00)83150-6