Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation

被引:46
作者
Harju, Jarkko [1 ]
Tarniceriu, Adrian [2 ]
Parak, Jakub [3 ,4 ]
Vehkaoja, Antti [3 ,4 ]
Yli-Hankala, Arvi [1 ,5 ]
Korhonen, Ilkka [3 ,4 ]
机构
[1] Tampere Univ Hosp, Dept Anesthesia, Tampere, Finland
[2] PulseOn SA, Neuchatel, Switzerland
[3] Tampere Univ Technol, Tampere, Finland
[4] Pulseon Oy, Espoo, Finland
[5] Univ Tampere, Med Sch, Tampere, Finland
关键词
heart rate; pulse rate; photoplethysmography; atrial fibrillation; perioperative monitoring; RATE-VARIABILITY; ACCURACY; PREVALENCE; FAILURE; WORN;
D O I
10.1088/1361-6579/aac9a9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpose of this study was to evaluate whether a wrist-worn photoplethysmography (PPG) device can be used to monitor beat-to-beat HR accurately during post-operative treatment in patients suffering from AF and whether wrist-PPG can be used to distinguish AF from sinus rhythm (SR). Approach: Twenty-nine patients (14 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine post-operative treatment. The monitoring included standard ECG, finger PPG monitoring and a wrist-worn PPG monitor with green and infrared light sources. The HR from PPG sensors was compared against ECG-derived HR. Main results: The wrist PPG technology had very good HR and beat detection accuracy when using green light. For the SR group, the mean absolute error (MAE) for HR was 1.50 bpm, and for the interbeat intervals (IBI), the MAE was 7.64 ms. For the AF group, the MAE for HR was 4.28 bpm and for IBI, the MAE was 14.67 ms. Accuracy for the infrared (IR) channel was worse. Finger PPG provided similar accuracy for HR and better accuracy for the IBI. AF detection sensitivity using green light was 99.0% and the specificity was 93.0%. Performance can be improved by discarding unreliable IBI periods. Significance: Results suggest that wrist PPG measurement allows accurate HR and beat-to-beat HR monitoring also in AF patients, and could be used for differentiating between SR and AF with very good sensitivity.
引用
收藏
页数:13
相关论文
共 41 条
  • [11] Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    Gil, E.
    Orini, M.
    Bailon, R.
    Vergara, J. M.
    Mainardi, L.
    Laguna, P.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1271 - 1290
  • [12] PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals
    Goldberger, AL
    Amaral, LAN
    Glass, L
    Hausdorff, JM
    Ivanov, PC
    Mark, RG
    Mietus, JE
    Moody, GB
    Peng, CK
    Stanley, HE
    [J]. CIRCULATION, 2000, 101 (23) : E215 - E220
  • [13] Guzman J., 2015, THESIS
  • [14] Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor
    Harju, Jarkko
    Vehkaoja, Antti
    Lindroos, Ville
    Kumpulainen, Pekka
    Liuhanen, Sasu
    Yli-Hankala, Arvi
    Oksala, Niku
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 1019 - 1026
  • [15] Clinical Evaluation of the Measurement Performance of the Philips Health Watch: A Within-Person Comparative Study
    Hendrikx, Jos
    Ruijs, Loes S.
    Cox, Lieke G. E.
    Lemmens, Paul M. C.
    Schuijers, Erik G. P.
    Goris, Annelies H. C.
    [J]. JMIR MHEALTH AND UHEALTH, 2017, 5 (02):
  • [16] Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study
    Kroll, Ryan R.
    Boyd, Gordon
    Maslove, David M.
    [J]. JOURNAL OF MEDICAL INTERNET RESEARCH, 2016, 18 (09)
  • [17] Lee J, 2013, IEEE ENG MED BIO, P1724, DOI 10.1109/EMBC.2013.6609852
  • [18] Atrial Fibrillation Detection Using an iPhone 4S
    Lee, Jinseok
    Reyes, Bersain A.
    McManus, David D.
    Mathias, Oscar
    Chon, Ki H.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (01) : 203 - 206
  • [19] The Advantages of Wearable Green Reflected Photoplethysmography
    Maeda, Yuka
    Sekine, Masaki
    Tamura, Toshiyo
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (05) : 829 - 834
  • [20] iPhone 4s Photoplethysmography: Which Light Color Yields the Most Accurate Heart Rate and Normalized Pulse Volume Using the iPhysioMeter Application in the Presence of Motion Artifact?
    Matsumura, Kenta
    Rolfe, Peter
    Lee, Jihyoung
    Yamakoshi, Takehiro
    [J]. PLOS ONE, 2014, 9 (03):