Determination of Pu isotopes in eawater by an on-line sequential injection technique with sector field inductively coupled plasma mass spectrometry

被引:53
作者
Kim, CS
Kim, CK
机构
[1] Korea Inst Nucl Safety, Dept Radiol Safety Res, Taejon 305338, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl Engn, Taejon 3731, South Korea
关键词
D O I
10.1021/ac0255328
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line sequential injection (SI) system combined with sector field inductively coupled plasma mass spectrometry was developed for the determination of ultratrace level Pu-239 and Pu-240 in seawater. The potential of this method is the substantial reduction of a sample volume and rapidity in the determination of Pu isotopes. A chemical purification and preconcentration of Pu isotopes were accomplished by the on-line S1 system with two micro-columns of solid-phase extraction resins, Sr-Spec and TEVA-Spec. The MCN-6000 microconcentric nebulizer was used as a sample introduction system because of low interference effect and good sample utilization. With this method, it was possible to analyze ultratrace levels of Pu isotopes in only 5 L of surface seawater with an analysis speed of 4 h/sample. The precision of the measurement for the Pu-239 and Pu-240 was less than 3.4 (n = 7) and 5% (n = 7) for 5 L of seawater. The detection limits for Pu-239 and Pu-240 were 0.64 (1.5 muBq/mL) and 0.19 fg/mL (1.6 muBq/mL), respectively. The accuracy of this method was verified by using the reference seawater (IAEA-381) as well as by the comparison with the alpha-spectrometry.
引用
收藏
页码:3824 / 3832
页数:9
相关论文
共 31 条
  • [11] Investigation and optimization of on-column redox reactions in the sorbent extraction separation of americium and plutonium using flow injection analysis
    Grate, JW
    Egorov, OB
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3920 - 3929
  • [12] THE APPLICATION OF NOVEL EXTRACTION CHROMATOGRAPHIC MATERIALS TO THE CHARACTERIZATION OF RADIOACTIVE-WASTE SOLUTIONS
    HORWITZ, EP
    DIETZ, ML
    CHIARIZIA, R
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (02): : 575 - 583
  • [13] HORWITZ EP, 1994, ANAL CHIM ACTA, V292, P263
  • [14] SEPARATION AND PRECONCENTRATION OF ACTINIDES FROM ACIDIC MEDIA BY EXTRACTION CHROMATOGRAPHY
    HORWITZ, EP
    CHIARIZIA, R
    DIETZ, ML
    DIAMOND, H
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (02) : 361 - 372
  • [15] *IAEA, 1999, IAEA381
  • [16] APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES IN ENVIRONMENTAL-SAMPLES - A REVIEW
    IGARASHI, Y
    KIM, CK
    TAKAKU, Y
    SHIRAISHI, K
    YAMAMOTO, M
    IKEDA, N
    [J]. ANALYTICAL SCIENCES, 1990, 6 (02) : 157 - 164
  • [17] KANG DJ, 1997, MAR POLLUT B, V35, P7
  • [18] Global distribution of Pu isotopes and 237Np
    Kelley, JM
    Bond, LA
    Beasley, TM
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 238 : 483 - 500
  • [19] APPLICATION OF A HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES
    KIM, CK
    SEKI, R
    MORITA, S
    YAMASAKI, S
    TSUMURA, A
    TAKAKU, Y
    IGARASHI, Y
    YAMAMOTO, M
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) : 205 - 209
  • [20] Distribution of H-3 Cs-137 and Pu-239,Pu-240 in the surface seawater around Korea
    Kim, CK
    Kim, CS
    Yun, JY
    Kim, KH
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 218 (01) : 33 - 40