Determination of Pu isotopes in eawater by an on-line sequential injection technique with sector field inductively coupled plasma mass spectrometry

被引:53
作者
Kim, CS
Kim, CK
机构
[1] Korea Inst Nucl Safety, Dept Radiol Safety Res, Taejon 305338, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl Engn, Taejon 3731, South Korea
关键词
D O I
10.1021/ac0255328
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line sequential injection (SI) system combined with sector field inductively coupled plasma mass spectrometry was developed for the determination of ultratrace level Pu-239 and Pu-240 in seawater. The potential of this method is the substantial reduction of a sample volume and rapidity in the determination of Pu isotopes. A chemical purification and preconcentration of Pu isotopes were accomplished by the on-line S1 system with two micro-columns of solid-phase extraction resins, Sr-Spec and TEVA-Spec. The MCN-6000 microconcentric nebulizer was used as a sample introduction system because of low interference effect and good sample utilization. With this method, it was possible to analyze ultratrace levels of Pu isotopes in only 5 L of surface seawater with an analysis speed of 4 h/sample. The precision of the measurement for the Pu-239 and Pu-240 was less than 3.4 (n = 7) and 5% (n = 7) for 5 L of seawater. The detection limits for Pu-239 and Pu-240 were 0.64 (1.5 muBq/mL) and 0.19 fg/mL (1.6 muBq/mL), respectively. The accuracy of this method was verified by using the reference seawater (IAEA-381) as well as by the comparison with the alpha-spectrometry.
引用
收藏
页码:3824 / 3832
页数:9
相关论文
共 31 条
[11]   Investigation and optimization of on-column redox reactions in the sorbent extraction separation of americium and plutonium using flow injection analysis [J].
Grate, JW ;
Egorov, OB .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3920-3929
[12]   THE APPLICATION OF NOVEL EXTRACTION CHROMATOGRAPHIC MATERIALS TO THE CHARACTERIZATION OF RADIOACTIVE-WASTE SOLUTIONS [J].
HORWITZ, EP ;
DIETZ, ML ;
CHIARIZIA, R .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (02) :575-583
[13]  
HORWITZ EP, 1994, ANAL CHIM ACTA, V292, P263
[14]   SEPARATION AND PRECONCENTRATION OF ACTINIDES FROM ACIDIC MEDIA BY EXTRACTION CHROMATOGRAPHY [J].
HORWITZ, EP ;
CHIARIZIA, R ;
DIETZ, ML ;
DIAMOND, H .
ANALYTICA CHIMICA ACTA, 1993, 281 (02) :361-372
[15]  
*IAEA, 1999, IAEA381
[16]   APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES IN ENVIRONMENTAL-SAMPLES - A REVIEW [J].
IGARASHI, Y ;
KIM, CK ;
TAKAKU, Y ;
SHIRAISHI, K ;
YAMAMOTO, M ;
IKEDA, N .
ANALYTICAL SCIENCES, 1990, 6 (02) :157-164
[17]  
KANG DJ, 1997, MAR POLLUT B, V35, P7
[18]   Global distribution of Pu isotopes and 237Np [J].
Kelley, JM ;
Bond, LA ;
Beasley, TM .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 238 :483-500
[19]   APPLICATION OF A HIGH-RESOLUTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER TO THE MEASUREMENT OF LONG-LIVED RADIONUCLIDES [J].
KIM, CK ;
SEKI, R ;
MORITA, S ;
YAMASAKI, S ;
TSUMURA, A ;
TAKAKU, Y ;
IGARASHI, Y ;
YAMAMOTO, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :205-209
[20]   Distribution of H-3 Cs-137 and Pu-239,Pu-240 in the surface seawater around Korea [J].
Kim, CK ;
Kim, CS ;
Yun, JY ;
Kim, KH .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 218 (01) :33-40