Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI

被引:16
作者
Ding, Yu [1 ]
Chung, Yiu-Cho [2 ]
Raman, Subha V. [1 ,3 ]
Simonetti, Orlando P. [1 ,3 ,4 ,5 ]
机构
[1] Ohio State Univ, Davis Heart & Lung Res Inst, Columbus, OH 43210 USA
[2] Siemens Med Solut Inc, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Internal Med, Columbus, OH 43210 USA
[4] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
GATED SPECT IMAGES; RECONSTRUCTION; COMPONENTS;
D O I
10.1088/0031-9155/54/12/020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Real-time dynamic magnetic resonance imaging (MRI) typically sacrifices the signal-to-noise ratio (SNR) to achieve higher spatial and temporal resolution. Spatial and/or temporal filtering (e.g., low-pass filtering or averaging) of dynamic images improves the SNR at the expense of edge sharpness. We describe the application of a temporal filter for dynamic MRimage series based on the Karhunen-Loeve transform (KLT) to remove random noise without blurring stationary or moving edges and requiring no training data. In this paper, we present several properties of this filter and their effects on filter performance, and propose an automatic way to find the filter cutoff based on the autocorrelation of the eigenimages. Numerical simulation and in vivo real-time cardiac cine MR image series spanning multiple cardiac cycles acquired usingmulti-channel sensitivity-encoded MRI, i.e., parallel imaging, are used to validate and demonstrate these properties. We found that in this application, the noise standard deviation was reduced to 42% of the original with no apparent image blurring by using the proposed filter cutoff. Greater noise reduction can be achieved by increasing the length of the image series. This advantage of KLT filtering provides flexibility in the form of another scan parameter to trade for SNR.
引用
收藏
页码:3909 / 3922
页数:14
相关论文
共 31 条
[1]   Application of Karhunen-Loeve transform in nuclear cardiology: Spatio-temporal smoothing and quantitative image analysis [J].
Blagosklonov, O ;
Sabbah, A ;
Verdenet, J ;
Cardot, JC .
COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 :299-302
[2]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[3]   Nonlinear approximation of random functions [J].
Cohen, A ;
DAles, JP .
SIAM JOURNAL ON APPLIED MATHEMATICS, 1997, 57 (02) :518-540
[4]   Coronary artery imaging using contrast-enhanced 3D segmented EPI [J].
Deshpande, VS ;
Wielopolski, PA ;
Shea, SM ;
Carr, J ;
Zheng, J ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) :676-681
[5]   DE-NOISING BY SOFT-THRESHOLDING [J].
DONOHO, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1995, 41 (03) :613-627
[6]   Adapting to unknown smoothness via wavelet shrinkage [J].
Donoho, DL ;
Johnstone, IM .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1995, 90 (432) :1200-1224
[7]   IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES [J].
FOO, TKF ;
BERNSTEIN, MA ;
AISEN, AM ;
HERNANDEZ, RJ ;
COLLICK, BD ;
BERNSTEIN, T .
RADIOLOGY, 1995, 195 (02) :471-478
[8]   Improvement of quantification of myocardial first-pass perfusion mapping: A temporal and spatial wavelet denoising method [J].
Goldstein, Thomas A. ;
Zhang, Haosen ;
Misselwitz, Bernd ;
Gropler, Robert G. ;
Zheng, Jie .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :439-445
[9]  
Golub G. H., 2012, Matrix computations, V4th
[10]  
Gonzalez R. C., 1992, DIGITAL IMAGE PROCES, V2nd