Preservation of Donor Hearts Using Hypothermic Oxygenated Perfusion

被引:3
作者
Michel, Sebastian G. [1 ,2 ,3 ]
La Muraglia, Glenn M., II [1 ,2 ]
Madariaga, Maria Lucia L. [1 ,2 ]
Titus, James S. [4 ]
Selig, Martin K. [5 ]
Farkash, Evan A. [5 ]
Allan, James S. [1 ,2 ,6 ]
Anderson, Lisa M. [7 ]
Madsen, Joren C. [1 ,2 ,4 ]
机构
[1] Massachusetts Gen Hosp, Dept Surg, Transplantat Biol Res Ctr, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ Munich, Klinikum Grosshadern, Dept Cardiac Surg, D-80539 Munich, Germany
[4] Massachusetts Gen Hosp, Dept Surg, Div Cardiac Surg, Boston, MA 02114 USA
[5] Massachusetts Gen Hosp, Dept Pathol, Boston, MA 02114 USA
[6] Massachusetts Gen Hosp, Dept Surg, Div Thorac Surg, Boston, MA 02114 USA
[7] Paragonix Technol Inc, Braintree, MA USA
关键词
Heart Transplantation; Organ Preservation; Pulsatile Flow; MACHINE PERFUSION; INTERNATIONAL SOCIETY; ENDOTHELIAL FUNCTION; NONPULSATILE FLOW; TRANSPLANTATION; PULSATILE; DEATH; LUNG; VIABILITY; RECOVERY;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Hypothermic machine perfusion of donor hearts enables continuous aerobic metabolism and washout of toxic metabolic byproducts. We evaluated the effect of machine perfusion on cardiac myocyte integrity in hearts preserved for 4 h in a novel device that provides pulsatile oxygenated hypothermic perfusion (Paragonix Sherpa Perfusion T Cardiac Transport System). Material/Methods: Pig hearts were harvested and stored in Celsior (R) solution for 4 h using either conventional cold storage on ice (4-h CS, n=6) or the Sherpa device (4-h pulsatile perfusion (PP), n=6). After cold preservation, hearts were evaluated using a non-working heart Langendorff system. Controls (n=3) were reperfused immediately after organ harvest. Biopsies were taken from the apex of the left ventricle before storage, after storage, and after reperfusion to measure ATP content and endothelin-1 in the tissue. Ultrastructural analysis using electron microscopy was performed. Results: Four-hour CS, 4-h PP, and control group did not show any significant differences in systolic or diastolic function (+dP/dt, -dP/dt, EDP). Four-hour PP hearts showed significantly more weight gain than 4-h CS after preservation, which shows that machine perfusion led to myocardial edema. Four-hour CS led to higher endothelin-1 levels after preservation, suggesting more endothelial dysfunction compared to 4-h PP. Electron microscopy revealed endothelial cell rupture and damaged muscle fibers in the 4-h CS group after reperfusion, but the cell structures were preserved in the 4-h PP group. Conclusions: Hypothermic pulsatile perfusion of donor hearts leads to a better-preserved cell structure compared to the conventional cold storage method. This may lead to less risk of primary graft failure after orthotopic heart transplantation.
引用
收藏
页数:8
相关论文
共 30 条
[1]   Cardiac Recovery in a Human Non-Heart-beating Donor After Extracorporeal Perfusion: Source for Human Heart Donation? [J].
Ali, Ayyaz ;
White, Paul ;
Dhital, Kumud ;
Ryan, Marian ;
Tsui, Steven ;
Large, Stephen .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (03) :290-293
[2]   The boundaries of organ donation after circulatory death [J].
Bernat, James L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (07) :669-671
[3]   BENEFICIAL-EFFECTS OF PULSATILE PERFUSION IN THE HYPERTROPHIED VENTRICLE DURING VENTRICULAR-FIBRILLATION [J].
BIXLER, TJ ;
MAGEE, PG ;
FLAHERTY, JT ;
GARDNER, TJ ;
GOTT, VL .
CIRCULATION, 1979, 60 (02) :I141-I146
[4]   Machine perfusion for cardiac allograft preservation [J].
Cobert, Michael L. ;
West, LaShondra M. ;
Jessen, Michael E. .
CURRENT OPINION IN ORGAN TRANSPLANTATION, 2008, 13 (05) :526-530
[5]   Preserving and evaluating hearts with ex vivo machine perfusion: an avenue to improve early graft performance and expand the donor pool [J].
Collins, Michael J. ;
Moainie, Sina L. ;
Griffith, Bartley P. ;
Poston, Robert S. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 34 (02) :318-325
[6]   COMPARISON OF DIFFERENT TECHNIQUES OF HYPOTHERMIC PIG-HEART PRESERVATION [J].
FERRERA, R ;
LARESE, A ;
MARCSEK, P ;
GUIDOLLET, J ;
VERDYS, M ;
DITTMAR, A ;
DUREAU, G .
ANNALS OF THORACIC SURGERY, 1994, 57 (05) :1233-1239
[7]   PERITRANSPLANT INJURY TO THE MYOCARDIUM ASSOCIATED WITH THE DEVELOPMENT OF ACCELERATED ARTERIOSCLEROSIS IN HEART-TRANSPLANT RECIPIENTS [J].
GAUDIN, PB ;
RAYBURN, BK ;
HUTCHINS, GM ;
KASPER, EK ;
BAUGHMAN, KL ;
GOODMAN, SN ;
LECKS, LE ;
BAUMGARTNER, WA ;
HRUBAN, RH .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1994, 18 (04) :338-346
[8]   Continuous perfusion of donor hearts in the beating state extends preservation time and improves recovery of function [J].
Hassanein, WH ;
Zellos, L ;
Tyrrell, TA ;
Healey, NA ;
Crittenden, MD ;
Birjiniuk, V ;
Khuri, SF .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) :821-829
[9]   Effects of lack of pulsatility on pulmonary endothelial function in the Fontan circulation [J].
Henaine, Roland ;
Vergnat, Mathieu ;
Bacha, Emile A. ;
Baudet, Bruno ;
Lambert, Virginie ;
Belli, Emre ;
Serraf, Alain .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (03) :522-529
[10]   Primary Graft Failure after Heart Transplantation [J].
Iyer, Arjun ;
Kumarasinghe, Gayathri ;
Hicks, Mark ;
Watson, Alasdair ;
Gao, Ling ;
Doyle, Aoife ;
Keogh, Anne ;
Kotlyar, Eugene ;
Hayward, Christopher ;
Dhital, Kumud ;
Granger, Emily ;
Jansz, Paul ;
Pye, Roger ;
Spratt, Phillip ;
Macdonald, Peter Simon .
JOURNAL OF TRANSPLANTATION, 2011, 2011