摘要
This article reviews the ultrasound (US) scanner setting, the examination methodology, and the anatomy of the skin. Dermatologic US requires frequencies of 15 MHz or greater and appropriate probe handling. The use of color Doppler imaging is mandatory, proven that it is set to detect slow flows. Trapezoid field of view, extended field of view, 3-dimensional reconstruction, elastography, and new microvasculature imaging facilities can help, if available. Operators must be aware of the adjustments and tricks useful to improve the image quality. High-resolution US allows detailed assessment of epidermis, dermis, subcutaneous tissue, and skin appendages. Differences exist according to patient age, sex, and body area. Appropriate knowledge of the anatomy is mandatory to image skin abnormalities.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [1] High-Resolution ultrasound of the pudendal nerve: Normal anatomy
    Tagliafico, Alberto
    Perez, Maribel Miguel
    Martinoli, Carlo
    MUSCLE & NERVE, 2013, 47 (03) : 403 - 408
  • [2] High-Resolution Laryngeal US: Imaging Technique, Normal Anatomy, and Spectrum of Disease
    Beale, Timothy
    Twigg, Victoria M.
    Horta, Mariana
    Morley, Simon
    RADIOGRAPHICS, 2020, 40 (03) : 775 - 790
  • [3] High-resolution ultrasound imaging of the mouse
    Renault, G.
    Bonnin, P.
    Marchiol-Fournigault, C.
    Gregoire, J. M.
    Serriere, S.
    Richard, B.
    Fradelizi, D.
    JOURNAL DE RADIOLOGIE, 2006, 87 (12): : 1937 - 1945
  • [4] Techniques and applications of noninvasive high-resolution ultrasound imaging
    Gregoire, J-M
    Serriere, S.
    Georgesco, G.
    Jamet, F.
    Bleuzen, A.
    Ossant, F.
    Levassort, F.
    Tranquart, F.
    Patat, F.
    JOURNAL DE RADIOLOGIE, 2006, 87 (12): : 1920 - 1936
  • [5] High-resolution ultrasound anatomy of extrinsic carpal ligaments
    Lacelli, F.
    Muda, A.
    Sconfienza, L. M.
    Schettini, D.
    Garlaschi, G.
    Silvestri, E.
    RADIOLOGIA MEDICA, 2008, 113 (04): : 504 - 516
  • [6] High-resolution ultrasound anatomy of extrinsic carpal ligaments
    Lacelli F.
    Muda A.
    Sconfienza L.M.
    Schettini D.
    Garlaschi G.
    Silvestri E.
    La radiologia medica, 2008, 113 (4) : 504 - 516
  • [7] High-Resolution MR Imaging and US Anatomy of the Thumb
    Rawat, Udit
    Pierce, Jennifer L.
    Evans, Scott
    Chhabra, A. Bobby
    Nacey, Nicholas C.
    RADIOGRAPHICS, 2016, 36 (06) : 1701 - 1716
  • [8] High-resolution Imaging of Neural Anatomy and Pathology of the Neck
    Lee, Jeong Hyun
    Cheng, Kai-Lung
    Choi, Young Jun
    Baek, Jung Hwan
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (01) : 180 - 193
  • [9] Enhancing knee imaging via histology and anatomy-driven high-resolution musculoskeletal ultrasound
    Tamborrini, Giorgio
    Micheroli, Raphael
    Ricci, Vincenzo
    Becciolini, Marco
    Garcia-Pompermayer, Mario
    Gonzalo, Andres Serrano Belmar
    Toranelli, Mireille
    Margenfeld, Felix
    Mueller-Gerbl, Magdalena
    JOURNAL OF ULTRASONOGRAPHY, 2025, 25 (100)
  • [10] A high-resolution technique for ultrasound harmonic imaging using sparse representations in Gabor frames
    Michailovich, O
    Adam, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (12) : 1490 - 1503