Detection and estimation of liquid flow through a pipe in a tissue-like object with ultrasound-assisted diffuse correlation spectroscopy

被引:9
作者
Chandran, R. Sriram [1 ,2 ]
Devaraj, G. [3 ]
Kanhirodan, Rajan [4 ]
Roy, Debasish [3 ]
Vasu, Ram Mohan [1 ,2 ]
机构
[1] Indian Inst Sci, Dept Instrumentat, Bangalore 560012, Karnataka, India
[2] Indian Inst Sci, Appl Phys Dept, Bangalore 560012, Karnataka, India
[3] Indian Inst Sci, Dept Civil Engn, Computat Mech Lab, Bangalore 560012, Karnataka, India
[4] Indian Inst Sci, Dept Phys, Bangalore 560012, Karnataka, India
关键词
CEREBRAL-BLOOD-FLOW; OPTICAL COHERENCE TOMOGRAPHY; MULTIPLE LIGHT-SCATTERING; BOUNDARY MEASUREMENT; WAVE SPECTROSCOPY; LASER-DOPPLER; TURBID MEDIA; SPECKLE; RECOVERY; MOTION;
D O I
10.1364/JOSAA.32.001888
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Using coherent light interrogating a turbid object perturbed by a focused ultrasound (US) beam, we demonstrate localized measurement of dynamics in the focal region, termed the region-of-interest (ROI), from the decay of the modulation in intensity autocorrelation of light. When the ROI contains a pipe flow, the decay is shown to be sensitive to the average flow velocity from which the mean-squared displacement (MSD) of the scattering centers in the flow can be estimated. While the MSD estimated is seen to be an order of magnitude higher than that obtainable through the usual diffusing wave spectroscopy (DWS) without the US, it is seen to be more accurate as verified by the volume flow estimated from it. It is further observed that, whereas the MSD from the localized measurement grows with time as tau(alpha) with alpha approximate to 1.65, without using the US, a is seen to be much less. Moreover, with the local measurement, this super-diffusive nature of the pipe flow is seen to persist longer, i.e., over a wider range of initial tau, than with the unassisted DWS. The reason for the super-diffusivity of flow, i.e., alpha < 2, in the ROI is the presence of a fluctuating (thermodynamically nonequilibrium) component in the dynamics induced by the US forcing. Beyond this initial range, both methods measure MSDs that rise linearly with time, indicating that ballistic and near-ballistic photons hardly capture anything beyond the background Brownian motion. (C) 2015 Optical Society of America
引用
收藏
页码:1888 / 1897
页数:10
相关论文
共 34 条
[1]   CORRELATION TRANSFER - APPLICATION OF RADIATIVE-TRANSFER SOLUTION METHODS TO PHOTON-CORRELATION PROBLEMS [J].
ACKERSON, BJ ;
DOUGHERTY, RL ;
REGUIGUI, NM ;
NOBBMANN, U .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1992, 6 (04) :577-588
[2]   Speckle-visibility spectroscopy: A tool to study time-varying dynamics [J].
Bandyopadhyay, R ;
Gittings, AS ;
Suh, SS ;
Dixon, PK ;
Durian, DJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09)
[3]  
BICOUT D, 1991, J PHYS I, V1, P471, DOI 10.1051/jp1:1991147
[4]   MULTIPLE LIGHT-SCATTERING IN TAYLOR-COUETTE FLOW [J].
BICOUT, D ;
MARET, G .
PHYSICA A, 1994, 210 (1-2) :87-112
[5]   DIFFUSING WAVE SPECTROSCOPY IN INHOMOGENEOUS FLOWS [J].
BICOUT, D ;
MAYNARD, R .
PHYSICA A, 1993, 199 (3-4) :387-411
[6]   Spatially varying dynamical properties of turbid media probed with diffusing temporal light correlation [J].
Boas, DA ;
Yodh, AG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (01) :192-215
[7]  
Bohren C.F, 2008, Absorption and Scattering of Light by Small Particles
[8]   Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging [J].
Briers, JD .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (04) :R35-R66
[9]   Diffusing-wave spectroscopy in an inhomogeneous object: Local viscoelastic spectra from ultrasound-assisted measurement of correlation decay arising from the ultrasound focal volume [J].
Chandran, R. Sriram ;
Sarkar, Saikat ;
Kanhirodan, Rajan ;
Roy, Debasish ;
Vasu, Ram Mohan .
PHYSICAL REVIEW E, 2014, 90 (01)
[10]   Design, fabrication, and characterization of a tissue-equivalent phantom for optical elastography [J].
Devi, CU ;
Vasu, RM ;
Sood, AK .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)