Determination of the electrode potential causing Faradaic reactions in membrane capacitive deionization

被引:80
作者
Choi, Jae-Hwan [1 ]
机构
[1] Kongju Natl Univ, Dept Chem Engn, Cheonan 331717, Chungnam, South Korea
基金
新加坡国家研究基金会;
关键词
Membrane capacitive deionization; Constant current; Electrode reaction; Faradaic current; Electrode potential; ANION-EXCHANGE MEMBRANES; CARBON ELECTRODE; DESALINATION EFFICIENCY; ENERGY-CONSUMPTION; MESOPOROUS CARBON; BRACKISH-WATER; PROTON LEAKAGE; IMPROVEMENT; POLYMER; FUTURE;
D O I
10.1016/j.desal.2014.06.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, the potential at which electrode reactions start and the effects of these reactions on membrane capacitive deionization (MCDI) were investigated. An adsorption experiment was conducted until the cell potential reached 1.2 V, applying constant current to an MCDI unit cell. While varying the current density (5.0-20.0 A/m(2)), the changes in cell potential, electrical conductivity and effluent pH were measured. The results of the experiment showed that the ion adsorption decreased significantly as the current density increased. Furthermore, the pH of the effluent rapidly decreased beyond a certain time in the adsorption process, which is judged to be the result of electrode reactions. When the electrode reactions started, the cell voltages were in the range of 0.62-0.90 V, which varied greatly depending on the current density. Using a simple model for the MCDI cell, the electrode potential was calculated from the cell potential and current density. Regardless of the current density applied, the electrode reaction was started at the electrode potential of 0.25 V. It is desirable to use the electrode potential instead of the cell potential to analyze the electrode reactions in MCDI operation. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:224 / 229
页数:6
相关论文
共 35 条
[1]  
Andelman M.D., 2002, Can. Patent, Patent No. [CA 2444390, 2444390]
[2]   Capacitive deionization as an electrochemical means of saving energy and delivering clean water. Comparison to present desalination practices: Will it compete? [J].
Anderson, Marc A. ;
Cudero, Ana L. ;
Palma, Jesus .
ELECTROCHIMICA ACTA, 2010, 55 (12) :3845-3856
[3]  
[Anonymous], 2004, ION EXCHANGE MEMBRAN
[4]  
[Anonymous], 1999, ELECTROCHEMICAL SUPE
[5]  
Bard J., 2001, ELECTROCHEMICAL METH
[6]   Theory of membrane capacitive deionization including the effect of the electrode pore space [J].
Biesheuvel, P. M. ;
Zhao, R. ;
Porada, S. ;
van der Wal, A. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2011, 360 (01) :239-248
[7]   Membrane capacitive deionization [J].
Biesheuvel, P. M. ;
van der Wal, A. .
JOURNAL OF MEMBRANE SCIENCE, 2010, 346 (02) :256-262
[8]   A control system for operating and investigating reactors: The demonstration of parasitic reactions in the water desalination by capacitive de-ionization [J].
Bouhadana, Yaniv ;
Ben-Tzion, Moshe ;
Soffer, Abraham ;
Aurbach, Doron .
DESALINATION, 2011, 268 (1-3) :253-261
[9]   Kinetic and isotherm studies on the electrosorption of NaCl from aqueous solutions by activated carbon electrodes [J].
Chen, Zhaolin ;
Song, Cunyi ;
Sun, Xiaowei ;
Guo, Hongfei ;
Zhu, Guangdong .
DESALINATION, 2011, 267 (2-3) :239-243
[10]  
Crow D.R., 1994, PRINCIPLES APPL ELEC, V4th