A VMAT planning technique for locally advanced breast cancer patients with expander or implant reconstructions requiring comprehensive postmastectomy radiation therapy

被引:26
作者
Kuo, LiCheng [1 ]
Ballangrud, Ase M. [1 ]
Ho, Alice Y. [2 ]
Mechalakos, James G. [1 ]
Li, Guang [1 ]
Hong, Linda [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10065 USA
关键词
PMRT; VMAT; CHEST-WALL; QUALITY; RADIOTHERAPY; IMPACT;
D O I
10.1016/j.meddos.2018.04.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Locally advanced breast cancer patients with expander or implant reconstructions who require comprehensive postmastectomy radiotherapy (PMRT) can pose unique treatment planning challenges. Traditional 3D conformal radiation techniques often result in large dose inhomogeneity throughout the treatment volumes, inadequate target coverage, or excessive normal tissue doses. We have developed a volumetric modulated arc therapy (VMAT) planning technique without entering through the ipsilateral arm that produced adequate target volume coverage, excellent homogeneity throughout the target volume, and acceptable doses to the normal structures. Twenty left-sided and 10 right-sided patients with either ipsilateral or bilateral permanent implants or tissue expanders who received comprehensive PMRT between October 2014 and February 2016 were included in this study. Ten left-sided cases used deep inspiration breath hold (DIBH) technique, and others used free breathing (FB). Planning target volume (PTV) included chestwall, internal mammary nodes (IMNs), supraclavicular, and axillary lymph nodes. A VMAT plan using 4 or 5 partial arcs with 6 MV photon beam avoiding entering through the ipsilateral arm was generated for each patient. Prescription dose was 50Gy in 25 fractions. PTV coverage, maximum depth of IMNs, dose homogeneity and dose to the heart, lungs, thyroid, contralateral intact breast or implant, liver, stomach, left anterior descending artery, ipsilateral brachial plexus, esophagus, spinal cord, and total MU were evaluated. PTV D95% (Gy) was 49.6 +/- 0.9, 48.7 +/- 0.9, and 49.5 +/- 1.1; PTV D05% (Gy) was 55.7 +/- 0.6, 55.1 +/- 1.4, and 55.0 +/- 0.7; maximum depth of IMNs (cm) was 4.3 +/- 0.9, 4.6 +/- 1.1, and 4.9 +/- 2.3; ipsilateral lung, V20Gy (%) was 29.0 +/- 2.1, 28.8 +/- 2.5, and 27.5 +/- 3.4; heart mean dose (Gy) was 4.2 +/- 0.4, 7.5 +/- 1.1, and 6.6 +/- 0.8 for right-sided FB, left-sided FB, and left-sided DIBH cases, respectively. D95% of IMNs all received 100% prescription dose. The maximum dose (Gy) to the left anterior descending artery was 33.8 +/- 11.7 for left-sided FB and 31.4 +/- 7.3 for left-sided DIBH. VMAT technique avoiding ipsilateral arm can produce acceptable clinical plans for locally advanced breast cancer patients with expander or implant reconstructions receiving comprehensive PMRT. (C) 2018 American Association of Medical Dosimetrists. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:150 / 154
页数:5
相关论文
共 19 条
[1]  
Abe O, 2005, LANCET, V366, P2087, DOI 10.1016/s0140-6736(05)66544-0
[2]   Internal mammary node coverage: An investigation of presently accepted techniques [J].
Arthur, DW ;
Arnfield, MR ;
Warwicke, LA ;
Morris, MM ;
Zwicker, RD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :139-146
[3]   FEASIBILITY OF POSTMASTECTOMY TREATMENT WITH HELICAL TOMOTHERAPY [J].
Ashenafi, Michael ;
Boyd, Robert A. ;
Lee, Tae K. ;
Lo, Kenneth K. ;
Gibbons, John P. ;
Rosen, Isaac I. ;
Fontenot, Jonas D. ;
Hogstrom, Kenneth R. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03) :836-842
[4]  
Bellon J. R, 2016, RAD THERAPY TECHNIQU, P111
[5]   Risk of Ischemic Heart Disease in Women after Radiotherapy for Breast Cancer [J].
Darby, Sarah C. ;
Ewertz, Marianne ;
McGale, Paul ;
Bennet, Anna M. ;
Blom-Goldman, Ulla ;
Bronnum, Dorthe ;
Correa, Candace ;
Cutter, David ;
Gagliardi, Giovanna ;
Gigante, Bruna ;
Jensen, Maj-Britt ;
Nisbet, Andrew ;
Peto, Richard ;
Rahimi, Kazem ;
Taylor, Carolyn ;
Hall, Per .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (11) :987-998
[6]   Quality of life and patient satisfaction in breast cancer patients after immediate breast reconstruction:: a prospective study [J].
Elder, EE ;
Brandberg, Y ;
Björklund, T ;
Rylander, R ;
Lagergren, J ;
Jurell, G ;
Wickman, M ;
Sandelin, K .
BREAST, 2005, 14 (03) :201-208
[7]   Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy [J].
Ho, Alice Y. ;
Patel, Nisha ;
Ohri, Nisha ;
Morrow, Monica ;
Mehrara, Babak J. ;
Disa, Joseph J. ;
Cordeiro, Peter G. ;
Shi, Weiji ;
Zhang, Zhigang ;
Gelblum, Daphna ;
Nerbun, Claire T. ;
Woch, Katherine M. ;
Ballangrud, Ase ;
McCormick, Beryl ;
Powell, Simon N. .
MEDICAL DOSIMETRY, 2014, 39 (01) :18-22
[8]   EVALUATION OF FOUR TECHNIQUES USING INTENSITY-MODULATED RADIATION THERAPY FOR COMPREHENSIVE LOCOREGIONAL IRRADIATION OF BREAST CANCER [J].
Jagsi, Reshma ;
Moran, Jean ;
Marsh, Robin ;
Masi, Kathryn ;
Griffith, Kent A. ;
Pierce, Lori J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05) :1594-1603
[9]   Cardiac chamber and coronary artery doses associated with postmastectomy radiotherapy techniques to the chest wall and regional nodes [J].
Krueger, EA ;
Schipper, MJ ;
Koelling, T ;
Marsh, RB ;
Butler, JB ;
Pierce, LJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1195-1203
[10]   Comparison of Plan Quality Between Arm Avoidance (AA) Vs. Non Arm Avoidance VMAT Planning Techniques for Breast Cancer Patients with Bilateral Implant Reconstructions Receiving Postmastectomy Radiation [J].
Kuo, L. ;
Ballangrud, A. ;
Ho, A. ;
Mechalakos, J. ;
Li, G. ;
Hong, L. .
MEDICAL PHYSICS, 2015, 42 (06) :3380-3380