The added value of ECG-gating for the diagnosis of myocardial infarction using myocardial perfusion scintigraphy and artificial neural networks

被引:5
作者
Gjertsson, Peter [1 ]
Lomsky, Milan
Richter, Jens
Ohlsson, Mattias
Tout, Deborah
van Aswegen, Andries
Underwood, Richard
Edenbrandt, Lars
机构
[1] Sahlgrens Univ Hosp, Dept Clin Physiol, SE-41345 Gothenburg, Sweden
[2] WeAidU Europe AB, Lund, Sweden
[3] Lund Univ, Dept Theoret Phys, Lund, Sweden
[4] Royal Brompton Hosp, Dept Nucl Med, London, England
[5] Imperial Coll, Fac Med, London, England
关键词
computer assisted; heart function tests; image interpretation; myocardial infarction; neural networks; radionuclide imaging;
D O I
10.1111/j.1475-097X.2006.00694.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To assess the value of ECG-gating for the diagnosis of myocardial infarction using myocardial perfusion scintigraphy (MPS) and an artificial neural network. A total of 422 patients referred for MPS were studied using a one day Tc-99m-tetrofosmin protocol. Adenosine stress combined with submaximal dynamic exercise was used. The images were interpreted by one of three experienced clinicians and these interpretations regarding the presence or absence of myocardial infarction were used as the standard. A fully automated method using artificial neural networks was compared with the clinical interpretation. Either perfusion data alone or a combination of perfusion and function from ECG-gated images were used as input to different artificial neural networks. After a training session, the two types of neural networks were evaluated in separate test groups using an eightfold cross-validation procedure. The neural networks trained with both perfusion and ECG-gated images had a 4-7% higher specificity compared with the corresponding networks using perfusion data only, in four of five segments compared at the same level of sensitivity. The greatest improvement in specificity, from 70% to 77%, was seen in the inferior segment. In the septal and lateral segments the specificity rose from 73% to 77% and from 81% to 85%, respectively. In the anterior segment, the increase in specificity from 93% to 94% by adding functional data was not significant. The addition of functional information from ECG-gated MPS is of value for the diagnosis of myocardial infarction using an automated method of interpreting myocardial perfusion images.
引用
收藏
页码:301 / 304
页数:4
相关论文
共 21 条
[1]  
DEPUEY E, 1995, J NUCL MED, V36, P952
[2]  
Fleischmann S, 2004, J NUCL MED, V45, P754
[3]  
FUJITA H, 1992, J NUCL MED, V33, P272
[4]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[5]  
Hachamovitch R, 1998, CIRCULATION, V98, P654
[6]   A FEED FORWARD NEURAL-NETWORK FOR CLASSIFICATION OF BULLS-EYE MYOCARDIAL PERFUSION IMAGES [J].
HAMILTON, D ;
RILEY, PJ ;
MIOLA, UJ ;
AMRO, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (02) :108-115
[7]  
Hanson S. J., 1998, ADV NEURAL INFORM PR, P177
[8]  
HARRIS PJ, 1979, CIRCULATION, V60, P1259, DOI 10.1161/01.CIR.60.6.1259
[9]  
Lindahl D, 1997, J NUCL MED, V38, P1870
[10]  
Lindahl D, 1999, J NUCL MED, V40, P96