Design and Evaluation of a Low-Cost Smartphone Pulse Oximeter

被引:52
作者
Petersen, Christian L. [1 ]
Chen, Tso P. [1 ]
Ansermino, J. Mark [1 ]
Dumont, Guy A. [2 ]
机构
[1] Univ British Columbia, Dept Anesthesiol Pharmacol & Therapeut, Vancouver, BC V6T 1Z3, Canada
[2] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
关键词
CHILDREN; ANESTHESIA; PNEUMONIA; HYPOXEMIA; MORTALITY; DEATHS;
D O I
10.3390/s131216882
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Infectious diseases such as pneumonia take the lives of millions of children in low- and middle-income countries every year. Many of these deaths could be prevented with the availability of robust and low-cost diagnostic tools using integrated sensor technology. Pulse oximetry in particular, offers a unique non-invasive and specific test for an increase in the severity of many infectious diseases such as pneumonia. If pulse oximetry could be delivered on widely available mobile phones, it could become a compelling solution to global health challenges. Many lives could be saved if this technology was disseminated effectively in the affected regions of the world to rescue patients from the fatal consequences of these infectious diseases. We describe the implementation of such an oximeter that interfaces a conventional clinical oximeter finger sensor with a smartphone through the headset jack audio interface, and present a simulator-based systematic verification system to be used for automated validation of the sensor interface on different smartphones and media players. An excellent agreement was found between the simulator and the audio oximeter for both oxygen saturation and heart rate over a wide range of optical transmission levels on 4th and 5th generations of the iPod Touch™ and iPhone™ devices. © 2013 by the authors; licensee MDPI, Basel, Switzerland.
引用
收藏
页码:16882 / 16893
页数:12
相关论文
共 27 条
[1]  
[Anonymous], 2013, SMARTPH Q
[2]  
British Standards Institution (BSI), 2019, ISO 80601-2-61
[3]   Hypoxaemia in acute respiratory and non-respiratory illnesses in neonates and children in a developing country [J].
Duke, T ;
Blaschke, AJ ;
Sialis, S ;
Bonkowsky, JL .
ARCHIVES OF DISEASE IN CHILDHOOD, 2002, 86 (02) :108-112
[4]  
EICHHORN J H, 1986, Journal of the American Medical Association, V256, P1017, DOI 10.1001/jama.256.8.1017
[5]   Brief hospitalization and pulse oximetry for predicting amoxicillin treatment failure in children with severe pneumonia [J].
Fu, Linda Y. ;
Ruthazer, Robin ;
Wilson, Ira ;
Patel, Archana ;
Fox, LeAnne M. ;
Tuan, Tran Anh ;
Jeena, Prakash ;
Chisaka, Noel ;
Hassan, Mumtaz ;
Lozano, Juan ;
Maulen-Radovan, I. ;
Thea, Donald M. ;
Qazi, Shamim ;
Hibberd, Patricia .
PEDIATRICS, 2006, 118 (06) :E1822-E1830
[6]   Global operating theatre distribution and pulse oximetry supply: an estimation from reported data [J].
Funk, Luke M. ;
Weiser, Thomas G. ;
Berry, William R. ;
Lipsitz, Stuart R. ;
Merry, Alan F. ;
Enright, Angela C. ;
Wilson, Iain H. ;
Dziekan, Gerald ;
Gawande, Atul A. .
LANCET, 2010, 376 (9746) :1055-1061
[7]   Anaesthetic mortality rates in Western Australia 1980-2002 [J].
Gibbs, N ;
Rodoreda, P .
ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (05) :616-622
[8]   Anaesthesia in Malawi: complications and deaths [J].
Hansen, D ;
Gausi, SC ;
Merikebu, M .
TROPICAL DOCTOR, 2000, 30 (03) :146-149
[9]  
HEYWOOD AJ, 1989, ANN ROY COLL SURG, V71, P354
[10]   Usability testing of a prototype Phone Oximeter with healthcare providers in high- and low-medical resource environments [J].
Hudson, J. ;
Nguku, S. M. ;
Sleiman, J. ;
Karlen, W. ;
Dumont, G. A. ;
Petersen, C. L. ;
Warriner, C. B. ;
Ansermino, J. M. .
ANAESTHESIA, 2012, 67 (09) :957-967