Separations by gradient elution: Why are steep gradient profiles distorted and what is their impact on resolution in reversed-phase liquid chromatography

被引:32
作者
Gritti, Fabrice [1 ]
Guiochon, Georges [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
Gradient chromatography; Distorted gradients; Excess adsorption isotherms; Methanol; Acetonitrile; Symmetry-C-18; SHOCK LAYER THICKNESS; EXCESS ADSORPTION; DEAD-VOLUME; BAND; PERFORMANCE; COMPONENTS; PROPAGATION; SIMULATION; MIXTURES;
D O I
10.1016/j.chroma.2014.04.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The formation of a concentration shock layer of either methanol or acetonitrile used as the modifier in steep RPLC aqueous/organic gradients was predictable from their excess adsorption isotherm and was directly observed from their elution profiles recorded in UV absorption. A discontinuity of the concentration profile of the organic modifier arises and grows along the column. Its effects on the peak shapes and the resolution levels achieved in steep gradient chromatography were measured in the recorded chromatograms of a sample mixture containing 14 different analytes uniformly distributed across the gradient retention window. The results showed severe peak shape deformation for some compounds and a significant degradation of the baseline resolution of weakly (when using acetonitrile) and moderately (when using methanol) retained analytes. Solutions to limit this loss of resolution may lie in changing the initial gradient conditions or in adjusting the curvature of the gradient profile at the column inlet. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 75
页数:10
相关论文
共 38 条
[1]   Single-component shock layer analysis in elution chromatography [J].
Ahmad, T ;
Gritti, F ;
Lin, SC ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :977-984
[2]   CONTINUOUS FLOW SYSTEMS - DISTRIBUTION OF RESIDENCE TIMES [J].
DANCKWERTS, PV .
CHEMICAL ENGINEERING SCIENCE, 1953, 2 (01) :1-13
[3]  
DRAKE B, 1955, ARK KEMI, V8, P1
[4]   GRADIENT ELUTION CHROMATOGRAPHY AT VERY HIGH COLUMN LOADING - EFFECT OF THE DEVIATION FROM THE LANGMUIR MODEL ON THE BAND PROFILE OF A SINGLE COMPONENT [J].
ELFALLAH, MZ ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2244-2252
[5]   The ultimate band compression factor in gradient elution chromatography [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1178 (1-2) :79-91
[6]   Effect of the surface coverage of endcapped C18-silica on the excess adsorption isotherms of commonly used organic solvents from water in reversed phase liquid chromatography [J].
Gritti, Fabrice ;
Kazakevich, Y. V. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1169 (1-2) :111-124
[7]   Measurement of hold-up volumes in reverse-phase liquid chromatography - Definition and comparison between static and dynamic methods [J].
Gritti, Fabrice ;
Kazakevich, Yuri ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) :157-169
[8]   Thermodynamics of adsorption of binary aqueous organic liquid mixtures on a RPLC adsorbent [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (01) :85-99
[9]   The bandwidth in gradient elution chromatography with a retained organic modifier [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1145 (1-2) :67-82
[10]   The distortion of gradient profiles in reversed-phase liquid chromatography [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1340 :50-58