Electrochemistry and voltammetry of procaine using a carbon nanotube film coated electrode

被引:47
作者
Wu, Kangbing [1 ]
Wang, Hong
Chen, Fang
Hu, Shengshui
机构
[1] Huazhong Univ Sci & Technol, Dept Chem, Wuhan 430074, Peoples R China
[2] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
procaine; electrochemical determination; carbon nanotube-modified electrode;
D O I
10.1016/j.bioelechem.2005.05.002
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new rapid, convenient and sensitive electrochemical method is described for the determination of procaine in pharmaceutical preparations, based on the unique properties of a multi-wall carbon nanotube (MWNT) thin film. The electrochemical behavior of procaine at the MWNT film-coated glassy carbon electrode (GCE) was investigated in detail, showing that the MWNT-coated GCE exhibits electrocatalytic activity to the oxidation of procaine because of the significant peak current enhancement and the lowering of oxidation overpotential. Furthermore, the mechanism for the oxidation of procaine at the MWNT-coated GCE was also studied. Finally, various experimental parameters such as solution pH value, the amount of MWNT, accumulation conditions and scan rate were optimized for the determination of procaine, and a new method with detection limit of 2 x 10(-7) mol/L was developed for procaine determination. This newly proposed method was successfully demonstrated with procaine hydrochloride injection. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 149
页数:6
相关论文
共 19 条
[1]  
Abdullin I.F., 1994, ZH ANAL KHIM, V49, P773
[2]  
ARUTEMARTINEZ MI, 1989, J ANAL TOXICOL, V13, P341
[3]  
Boulkouze AA, 1991, J PHARM BIOMED ANAL, V9, P393
[4]   Fluorimetric determination of procaine in pharmaceutical preparations based on its reaction with fluorescamine [J].
Carretero, AS ;
Cruces-Blanco, C ;
Peinado, SF ;
El Bergmi, R ;
Gutiérrez, AF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (05) :969-974
[5]   SPECTROPHOTOMETRIC DETERMINATION OF CERTAIN LOCAL-ANESTHETICS USING 3-METHYLBENZOTHIAZOLIN-2-ONE HYDRAZONE [J].
ELKOMMOS, ME ;
EMARA, KM .
ANALYST, 1987, 112 (09) :1253-1256
[6]   Local anesthetics measured by lipophilic beta-cyclodextrin-based ion-selective electrodes [J].
Kataky, R ;
Palmer, S .
ELECTROANALYSIS, 1996, 8 (06) :585-590
[7]   Use of p-dimethylaminobenzalhyde as a colored reagent for determination of procaine hydrochloride by spectrophotometry [J].
Liu, LD ;
Liu, Y ;
Wang, HY ;
Sun, Y ;
Ma, L ;
Tang, B .
TALANTA, 2000, 52 (06) :991-999
[8]   Determination of procaine hydrochloride by ion-pairing flow injection analysis with piezoelectric detection [J].
Mo, ZH ;
Luo, J ;
Long, XH ;
Xia, ZL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (04) :556-558
[9]  
OGURTSOV VV, 1986, FARM ZH-KIEV, V4, P62
[10]   Simultaneous determination of local anesthetics including ester-type anesthetics in human plasma and urine by gas chromatography mass spectrometry with solid-phase extraction [J].
Ohshima, T ;
Takayasu, T .
JOURNAL OF CHROMATOGRAPHY B, 1999, 726 (1-2) :185-194