Electrochemically induced deposition of poly(benzoxazine) precursors as immobilization matrix for enzymes

被引:15
作者
Andronescu, Corina [1 ]
Poeller, Sascha [2 ]
Schuhmann, Wolfgang [2 ]
机构
[1] Univ Politehn Bucuresti, Dept Bioresources & Polymer Sci, Bucharest 010072, Romania
[2] Ruhr Univ Bochum, D-44780 Bochum, Germany
关键词
Poly(benzoxazine); Electrodeposition; Amperometric biosensor; Enzyme immobilization; Potential pulse deposition; PERFORMANCE; FILMS;
D O I
10.1016/j.elecom.2014.01.015
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Water-soluble benzoxazine oligomers were synthesized by reacting bisphenol A, tetraethylenepentamine and formaldehyde. The pre-formed benzoxazine oligomers can be further electropolymerized from aqueous suspensions under formation of poly(benzoxazine)-based films on electrode surfaces. Integration of glucose oxidase in a poly(benzoxazine) film let to highly reproducible and stable biosensors. Poly(benzoxazines) are proposed as a new family of stable polymers for the design of enzyme electrodes. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:12 / 15
页数:4
相关论文
共 13 条
[1]   Biobased Chitosan/Polybenzoxazine Cross-Linked Films: Preparation in Aqueous Media and Synergistic Improvements in Thermal and Mechanical Properties [J].
Alhwaige, Almahdi A. ;
Agag, Tarek ;
Ishida, Hatsuo ;
Qutubuddin, Syed .
BIOMACROMOLECULES, 2013, 14 (06) :1806-1815
[2]  
Chen W., 2009, FRONT CHEM CHINA, V4, P390, DOI [10.1007/s11458-009-0105-9, DOI 10.1007/S11458-009-0105-9]
[3]   Combinatorial microelectrochemistry:: Development and evaluation of an electrochemical robotic system -: art. no. 062204 [J].
Erichsen, T ;
Reiter, S ;
Ryabova, V ;
Bonsen, EM ;
Schuhmann, W ;
Märkle, W ;
Tittel, C ;
Jung, G ;
Speiser, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06)
[4]   Polybenzoxazines - New high performance thermosetting resins: Synthesis and properties [J].
Ghosh, N. N. ;
Kiskan, B. ;
Yagci, Y. .
PROGRESS IN POLYMER SCIENCE, 2007, 32 (11) :1344-1391
[5]   Electrochemical glucose sensors and their applications in diabetes management [J].
Heller, Adam ;
Feldman, Ben .
CHEMICAL REVIEWS, 2008, 108 (07) :2482-2505
[6]   Evaluation of performance and stability of biocatalytic redox films constructed with different copper oxygenases and osmium-based redox polymers [J].
Jenkins, Peter A. ;
Boland, Susan ;
Kavanagh, Paul ;
Leech, Donal .
BIOELECTROCHEMISTRY, 2009, 76 (1-2) :162-168
[7]   [Os(bpy)(2)(PVI)(10)Cl]Cl polymer-modified carbon fiber electrodes for the electrocatalytic oxidation of NADH [J].
Ju, HX ;
Leech, D .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :51-58
[8]   Polybenzoxazine-based composites as high-performance materials [J].
Kiskan, Baris ;
Ghosh, Narendra Nath ;
Yagci, Yusuf .
POLYMER INTERNATIONAL, 2011, 60 (02) :167-177
[9]   Immobilization method for the preparation of biosensors based on pH shift-induced deposition of biomolecule-containing polymer films [J].
Kurzawa, C ;
Hengstenberg, A ;
Schuhmann, W .
ANALYTICAL CHEMISTRY, 2002, 74 (02) :355-361
[10]   On the relationship between the characteristics of bilirubin oxidases and O2 cathodes based on their "wiring" [J].
Mano, N ;
Kim, HH ;
Heller, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (34) :8842-8848