Determination of the scattering coefficient and the anisotropy factor from laser Doppler spectra of liquids including blood

被引:36
作者
Kienle, A [1 ]
Patterson, MS [1 ]
Ott, L [1 ]
Steiner, R [1 ]
机构
[1] HAMILTON REG CANC CTR, DEPT MED PHYS, HAMILTON, ON L8V 5C2, CANADA
来源
APPLIED OPTICS | 1996年 / 35卷 / 19期
关键词
laser Doppler; Monte Carlo; anisotropy factor; blood;
D O I
10.1364/AO.35.003404
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser Doppler measurements were performed on scattering liquids flowing through a highly scattering static medium to determine the scattering coefficient and the anisotropy factor of the liquids. Monte Carlo simulations of light propagation in the static and moving media were used to calculate the Doppler spectra or suspensions of polystyrene spheres in water, and these spectra were in excellent agreement with experimental results. A faster Monte Carlo code was developed so that nonlinear regressions to the measured laser Doppler spectra could be used to determine the anisotropy factor of other liquids. This approach was used to deduce the scattering properties of Intralipid and blood at lambda = 820 nm. It was found that the anisotropy factor of blood is well described by Mie theory in contradiction to results reported in the literature that were obtained by goniometric measurement of the phase function. (C) 1996 Optical Society of America
引用
收藏
页码:3404 / 3412
页数:9
相关论文
共 20 条
[1]  
Bevington P., 2003, Data reduction and error analysis for the physical sciences
[2]   MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE [J].
BONNER, R ;
NOSSAL, R .
APPLIED OPTICS, 1981, 20 (12) :2097-2107
[3]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[4]  
DEMUL FFM, 1995, APPL OPTICS, V34, P6596
[5]   FREQUENCY-DOMAIN MULTICHANNEL OPTICAL-DETECTOR FOR NONINVASIVE TISSUE SPECTROSCOPY AND OXIMETRY [J].
FANTINI, S ;
FRANCESCHINI, MA ;
MAIER, JS ;
WALKER, SA ;
BARBIERI, B ;
GRATTON, E .
OPTICAL ENGINEERING, 1995, 34 (01) :32-42
[6]   THE USE OF A NEURAL NETWORK TO DETERMINE TISSUE OPTICAL-PROPERTIES FROM SPATIALLY RESOLVED DIFFUSE REFLECTANCE MEASUREMENTS [J].
FARRELL, TJ ;
WILSON, BC ;
PATTERSON, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (12) :2281-2286
[7]  
ISHIMARU A, 1978, WAVE PROPAGATION SCA, P64
[8]   MONTE-CARLO SIMULATIONS OF LASER DOPPLER BLOOD-FLOW MEASUREMENTS IN TISSUE [J].
JENTINK, HW ;
DEMUL, FFM ;
HERMSEN, RGAM ;
GRAAFF, R ;
GREVE, J .
APPLIED OPTICS, 1990, 29 (16) :2371-2381
[9]   Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue [J].
Kienle, A ;
Lilge, L ;
Patterson, MS ;
Hibst, R ;
Steiner, R ;
Wilson, BC .
APPLIED OPTICS, 1996, 35 (13) :2304-2314
[10]  
KIENLE A, 1994, THESIS U ULM ULM GER