Detection of lymph-node metastases in patients with gastric carcinoma: comparison of three MR imaging pulse sequences

被引:13
作者
Kato, M
Saji, S
Kanematsu, M
Fukada, D
Miya, K
Umemoto, T
Kunieda, K
Sugiyama, Y
Takao, H
Kawaguchi, Y
Takagi, Y
Kondo, H
Hoshi, H
机构
[1] Gifu Univ, Sch Med, Dept Surg 2, Gifu 5008705, Japan
[2] Gifu Univ, Sch Med, Dept Radiol, Gifu 5008705, Japan
来源
ABDOMINAL IMAGING | 2000年 / 25卷 / 01期
关键词
gastric carcinoma; lymph node; magnetic resonance; pulse sequence; receiver-characteristic-curve analysis;
D O I
10.1007/s002619910004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To compare the diagnostic accuracy of magnetic resonance (MR) images obtained with three different pulse sequences for lymph-node metastases in patients with gastric cancer. Methods: T1-weighted spin-echo (SE), breath-hold T2-weighted fast SE, and triphasic gadolinium-enhanced dynamic gradient-recall-echo (GRE) MR images obtained in 16 patients with gastric carcinoma were retrospectively reviewed. Regional lymph nodes were assigned to four different groups, and image review was conducted on a lymph-node group-by-group basis; 64 lymph-node groups were reviewed by two radiologists. Relative sensitivity, specificity, and accuracy were determined based on the findings with definitive surgery and follow-up imaging. Diagnostic accuracy was determined by means of receiver-operating-characteristic (ROC) analysis. Results: Relative sensitivities for lymph-node metastases with T1-weighted SE, breath-hold T2-weighted fast SE, and dynamic GRE images were 61%, 94%, and 59%, respectively. Relative sensitivity with breath-hold T2-weighted fast SE images was significantly greater than that with T1-weighted SE (p < 0.05) and dynamic GRE (p < 0.05) images. Diagnostic accuracy determined by ROC analysis was marginally higher with breath-hold T2-weighted fast SE (area under ROC curve [Az] = 0.87) than with T1-weighted SE (Az = 0.78, p = 0.08) and dynamic GRE (Az = 0.79, p = 0.12) images. Conclusion: Breath-hold T2-weighted fast SE sequence is useful in the detection of regional lymph-node metastases in patients with gastric carcinoma.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 14 条
[1]  
BOTET JF, 1991, RADIOLOGY, V18, P342
[2]   PREOPERATIVE ASSESSMENT OF GASTRIC-CARCINOMA - VALUE OF 2-PHASE DYNAMIC CT WITH MECHANICAL IV INJECTION OF CONTRAST MATERIAL [J].
CHO, JS ;
KIM, JK ;
RHO, SM ;
LEE, HY ;
JEONG, HY ;
LEE, CS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) :69-75
[3]   Spiral computed tomography and operative staging of gastric carcinoma: a comparison with histopathological staging [J].
Davies, J ;
Chalmers, AG ;
SueLing, HM ;
May, J ;
Miller, GV ;
Martin, IG ;
Johnston, D .
GUT, 1997, 41 (03) :314-319
[4]   THE PREOPERATIVE ASSESSMENT OF ADVANCED GASTRIC-CANCER BY COMPUTED-TOMOGRAPHY [J].
DEHN, TCB ;
REZNEK, RH ;
NOCKLER, IB ;
WHITE, FE .
BRITISH JOURNAL OF SURGERY, 1984, 71 (06) :413-417
[5]   UPPER ABDOMINAL LYMPH-NODES - CRITERIA FOR NORMAL SIZE DETERMINED WITH CT [J].
DORFMAN, RE ;
ALPERN, MB ;
GROSS, BH ;
SANDLER, MA .
RADIOLOGY, 1991, 180 (02) :319-322
[6]  
FUKAYA T, 1995, RADIOLOGY, V197, P705
[7]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[8]  
METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
[9]  
MISIKA S, 1989, WORLD J SURG, V13, P118
[10]  
NISHI M, 1995, JAPANESE CLASSIFICAT, P6