Experimental investigation and analytical modelling of blind bolted flush or extended end plate connections to circular CFDST columns

被引:35
|
作者
Guo, Lei [1 ]
Wang, Jingfeng [1 ,2 ]
Wu, Shuncheng [1 ]
Zhong, Liping [1 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 23009, Anhui, Peoples R China
[2] Anhui Key Lab Civil Engn Struct & Mat, Hefei 23009, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Circular concrete-filled double skin steel tubular; Curved end plate; Cyclic loading; Seismic performance; Analytical modelling; STUB COLUMNS; ANALYTICAL BEHAVIOR; SEISMIC RESPONSE; COMPOSITE JOINTS; TUBULAR COLUMNS; CFST FRAMES; CFT COLUMN; CHS INNER; BEAM; SQUARE;
D O I
10.1016/j.engstruct.2019.04.053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental program was carried out to investigate the seismic performance and analytical modelling of blind bolted flush or extended end plate connections to circular concrete filled double skin steel tubular (CFDST) columns. A series of cruciform assemblage specimens composed of circular CFDST columns and H-shaped steel beams were tested under lateral cyclic loads. The test parameters were determined as the curved end plate type and column hollow ratio. Typical failure modes for the connections to CFDST columns were analyzed by comparing with blind bolted connections to CFST columns, which indicated CFDST column blind bolted to steel beam connections significantly restricted the outward deformation of column wall. Moreover, the seismic performance of blind bolted connections between circular CFDST columns and steel beams was also estimated in terms of the moment (M) -rotation (theta(r)) relationship curves, ductility and energy dissipation capacities. Besides, the failure mechanism was studied through the analysis of strain responses. Analytical models were calibrated to estimate the initial stiffness and moment resistance of the blind bolted connections, which focused on the stiffness coefficients of curved flush and extended end plates in bending and the influence of circular CFDST column. The analytical models were verified against the experimental results. The experimental and analytical results indicated that the blind bolted flush or extended end plate connections to circular CFDST columns had superior seismic behavior and properly could meet the design demands in high-intensity seismic regions.
引用
收藏
页码:233 / 253
页数:21
相关论文
共 50 条
  • [1] Modelling of unstiffened flush end-plate bolted connections in fire
    Al-Jabri, KS
    Seibi, A
    Karrech, A
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (1-2) : 151 - 159
  • [2] Experimental and Analytical Behavior of Square CFDST Column Blind Bolted to Steel Beam Connections
    Wang, Jingfeng
    Guo, Lei
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2020, 20 (02) : 612 - 635
  • [3] Experimental and Analytical Behavior of Square CFDST Column Blind Bolted to Steel Beam Connections
    Jingfeng Wang
    Lei Guo
    International Journal of Steel Structures, 2020, 20 : 612 - 635
  • [4] Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections
    Yilmaz, Orkun
    Bekiroglu, Serkan
    Alemdar, Fatih
    Arslan, Guray
    Sevim, Barn
    Ayvaz, Yusuf
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2019, 16 (03):
  • [5] Experimental investigation on flush end-plate bolted composite connection in fire
    Li, Jiao-Ting
    Li, Guo-Qiang
    Lou, Guo-Biao
    Chen, Ling-zhu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 76 : 121 - 132
  • [6] Behaviour of flush end plate connections to concrete-filled tubular columns with blind bolts
    Wang, Jingfeng
    Han, Linhai
    Uy, Brian
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL, SPACE & COMPOSITE STRUCTURES, 2007, : 625 - +
  • [7] ANALYSIS OF BEAM-TO-COLUMN BOLTED FLUSH END PLATE CONNECTIONS
    Foces, Antonio
    Garrido, Jose Antonio
    Moreno, Alicia
    REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2007, 23 (01): : 35 - 53
  • [8] Experimental and analytical behavior of bolted end-plate connections with or without stiffeners
    Abidelah, A.
    Bouchair, A.
    Kerdal, D. E.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 76 : 13 - 27
  • [9] Experimental and numerical behaviour of blind bolted flush endplate composite connections
    Waqas, Rumman
    Uy, Brian
    Thai, Huu-Tai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 153 : 179 - 195
  • [10] Seismic response investigation on CFDST column to steel beam blind-bolted connections
    Wang, Jingfeng
    Guo, Lei
    Guo, Xiang
    Ding, Zhaodong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 161 : 137 - 153