A novel feature ranking algorithm for biometric recognition with PPG signals

被引:109
作者
Kavsaoglu, A. Resit [1 ]
Polat, Kemal [2 ]
Bozkurt, M. Recep [1 ]
机构
[1] Sakarya Univ, Fac Engn, Dept Elect & Elect Engn, TR-54187 Sakarya, Turkey
[2] Abant Izzet Baysal Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, TR-14280 Bolu, Turkey
关键词
Biometrics; Photoplethysmography (PPG); Identification; Classification; Derivatives; Feature Extraction; ECG ANALYSIS; PHOTOPLETHYSMOGRAM; SYSTEM;
D O I
10.1016/j.compbiomed.2014.03.005
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study is intended for describing the application of the Photoplethysmography (PPG) signal and the time domain features acquired from its first and second derivatives for biometric identification. For this purpose, a sum of 40 features has been extracted and a feature-ranking algorithm is proposed. This proposed algorithm calculates the contribution of each feature to biometric recognition and collocates the features, the contribution of which is from great to small. While identifying the contribution of the features, the Euclidean distance and absolute distance formulas are used. The efficiency of the proposed algorithms is demonstrated by the results of the k-NN (k-nearest neighbor) classifier applications of the features. During application, each 15-period-PPG signal belonging to two different durations from each of the thirty healthy subjects were used with a PPG data acquisition card. The first PPG signals recorded from the subjects were evaluated as the 1st configuration; the PPG signals recorded later at a different time as the 2nd configuration and the combination of both were evaluated as the 3rd configuration. When the results were evaluated for the k-NN classifier model created along with the proposed algorithm, an identification of 90.44% for the 1st configuration, 94.44% for the 2nd configuration, and 87.22% for the 3rd configuration has successfully been attained. The obtained results showed that both the proposed algorithm and the biometric identification model based on this developed PPG signal are very promising for contactless recognizing the people with the proposed method. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 37 条
  • [1] Peripheral hemodynamics evaluated by acceleration plethysmography in workers exposed to lead
    Aiba, Y
    Ohshiba, S
    Horiguchi, S
    Morioka, I
    Miyashita, K
    Kiyota, I
    Endo, G
    Takada, H
    Iwata, H
    [J]. INDUSTRIAL HEALTH, 1999, 37 (01) : 3 - 8
  • [2] Predicting arterial stiffness from the digital volume pulse waveform
    Alty, Stephen R.
    Angarita-Jaimes, Natalia
    Millasseau, Sandrine C.
    Chowienczyk, Philip J.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (12) : 2268 - 2275
  • [3] Bailey J, 2008, THESIS WORCESTER POL
  • [4] ECG analysis: A new approach in human identification
    Biel, L
    Pettersson, O
    Philipson, L
    Wide, P
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (03) : 808 - 812
  • [5] Biel L, 1999, IEEE IMTC P, P557, DOI 10.1109/IMTC.1999.776813
  • [6] FACE RECOGNITION - FEATURES VERSUS TEMPLATES
    BRUNELLI, R
    POGGIO, T
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (10) : 1042 - 1052
  • [7] Dumn D., 1993, P 4 INT C SIGN PROC
  • [8] On the Analysis of Fingertip Photoplethysmogram Signals
    Elgendi, Mohamed
    [J]. CURRENT CARDIOLOGY REVIEWS, 2012, 8 (01) : 14 - 25
  • [9] Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    Gil, E.
    Orini, M.
    Bailon, R.
    Vergara, J. M.
    Mainardi, L.
    Laguna, P.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1271 - 1290
  • [10] Gonzalez RC, 2008, Digital Image Processing