Comparison of a potentiometric and a micromechanical triglyceride biosensor

被引:30
作者
Fernandez, Renny Edwin [1 ]
Hareesh, Vemulachedu [1 ]
Bhattacharya, Enakshi [1 ]
Chadha, Anju [2 ,3 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
[2] Indian Inst Technol, Dept Biotechnol, Madras 600036, Tamil Nadu, India
[3] Indian Inst Technol, Natl Ctr Catalysis Res, Madras 600036, Tamil Nadu, India
关键词
EISCAP; Biosensor; Microcantilever; Triglyceride; SENSOR; IMMOBILIZATION; LIPASE;
D O I
10.1016/j.bios.2008.07.054
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Sensitive biosensors for detection of triglyceride concentration are important. In this paper we report on two types of silicon based triglyceride sensors: an electrolyte-insulator-semiconductor capacitor (EISCAP) which is a potentiometric device and a polysilicon microcantilever. The detection principle for both sensors is based on the enzymatic hydrolysis of triglyceride though the sensing mechanisms are different: electronic for the EISCAP and mechanical for the microcantilever. The characteristics and performances of the two sensors are critically compared. The EISCAP sensor necessitates the presence of a buffer for stable measurements which limits the sensitivity of the sensor at low concentrations of the bioanalyte to 1 mM. The cantilever sensor works without a buffer which improves the lower level of sensitivity to 10 mu m. Both sensors are found to give reproducible and reliable results. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1276 / 1280
页数:5
相关论文
共 17 条
[1]   Solid state potentiometric sensor for the estimation of tributyrin and urea [J].
Basu, I ;
Subramanian, RV ;
Mathew, A ;
Kayastha, AM ;
Chadha, A ;
Bhattacharya, E .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (01) :418-423
[4]   Parameter extraction from simple electrical measurements on surface micromachined cantilevers [J].
Bhat, Sornashekara ;
Bhattacharya, Enakshi .
JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2007, 6 (04)
[5]   Immobilization of RGD to ⟨111⟩ silicon surfaces for enhanced cell adhesion and proliferation [J].
Davis, DH ;
Giannoulis, CS ;
Johnson, RW ;
Desai, TA .
BIOMATERIALS, 2002, 23 (19) :4019-4027
[6]   DEVELOPMENT AND PRACTICAL EVALUATION OF AN AMPEROMETRIC TRIGLYCERIDE SENSOR [J].
FELDBRUGGE, R ;
RENNEBERG, R ;
SPENER, F .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) :365-367
[7]   Covalent immobilization of Pseudomonas cepacia lipase on semiconducting materials [J].
Fernandez, Renny Edwin ;
Bhattacharya, Enakshi ;
Chadha, Anju .
APPLIED SURFACE SCIENCE, 2008, 254 (15) :4512-4519
[8]   In situ silanization reaction on the surface of freshly prepared porous silicon [J].
Li, HL ;
Fu, AP ;
Xu, DS ;
Guo, GL ;
Gui, LL ;
Tang, YQ .
LANGMUIR, 2002, 18 (08) :3198-3202
[9]   LIPASE FROM A BRAZILIAN STRAIN OF PENICILLIUM-CITRINUM [J].
PIMENTEL, MCB ;
KRIEGER, N ;
COELHO, LCCB ;
FONTANA, JO ;
MELO, EHM ;
LEDINGHAM, WM ;
LIMA, JL .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1994, 49 (01) :59-74
[10]   Micromechanical cantilever-based biosensors [J].
Raiteri, R ;
Grattarola, M ;
Butt, HJ ;
Skládal, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (2-3) :115-126