Characterization of acoustic noise in a neonatal intensive care unit MRI system

被引:29
|
作者
Tkach, Jean A. [1 ]
Li, Yu [1 ]
Pratt, Ronald G. [1 ]
Baroch, Kelly A. [2 ]
Loew, Wolfgang [1 ]
Daniels, Barret R. [1 ]
Giaquinto, Randy O. [1 ]
Merhar, Stephanie L. [3 ]
Kline-Fath, Beth M. [4 ]
Dumoulin, Charles L. [1 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Imaging Res Ctr, Cincinnati, OH 45229 USA
[2] Cincinnati Childrens Hosp Med Ctr, Div Audiol, Cincinnati, OH 45229 USA
[3] Cincinnati Childrens Hosp Med Ctr, Perinatal Inst, Div Neonatol & Pulm Biol, Cincinnati, OH 45229 USA
[4] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
关键词
Magnetic resonance imaging; Neonatal intensive care unit; Acoustic noise; Safety; Neonates; CHLORAL HYDRATE; SEDATION; TRANSPORT; INFANTS; BRAIN; FETUS;
D O I
10.1007/s00247-014-2909-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To eliminate the medical risks and logistical challenges of transporting infants from the neonatal intensive care unit (NICU) to the radiology department for magnetic resonance imaging, a small-footprint 1.5-T MRI scanner has been developed for neonatal imaging within the NICU. MRI is known to be noisy, and exposure to excessive acoustic noise has the potential to elicit physiological distress and impact development in the term and preterm infant. To measure and compare the acoustic noise properties of the NICU MRI system against those of a conventional 1.5-T MRI system. We performed sound pressure level measurements in the NICU MRI scanner and in a conventional adult-size whole-body 1.5-T MRI system. Sound pressure level measurements were made for six standard clinical MR imaging protocols. The average sound pressure level value, reported in unweighted (dB) and A-weighted (dBA) decibels for all six imaging pulse sequences, was 73.8 dB and 88 dBA for the NICU scanner, and 87 dB and 98.4 dBA for the conventional MRI scanner. The sound pressure level values measured on the NICU scanner for each of the six MR imaging pulse sequences were consistently and significantly (P = 0.03) lower, with an average difference of 14.2 dB (range 10-21 dB) and 11 dBA (range 5-18 dBA). The sound pressure level frequency response of the two MR systems showed a similar harmonic structure above 200 Hz for all imaging sequences. The amplitude, however, was appreciably lower for the NICU scanner, by as much as 30 dB, for frequencies below 200 Hz. The NICU MRI system is quieter than conventional MRI scanners, improving safety for the neonate and facilitating siting of the unit within the NICU.
引用
收藏
页码:1011 / 1019
页数:9
相关论文
共 50 条
  • [41] Reduction of noise in the neonatal intensive care unit using sound-activated noise meters
    Wang, D.
    Aubertin, C.
    Barrowman, N.
    Moreau, K.
    Dunn, S.
    Harrold, J.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2014, 99 (06): : F515 - F516
  • [42] Palliative care in a neonatal intensive care unit
    Gold, Jeffrey I.
    Nelson, Lara P.
    JOURNAL OF CRITICAL CARE, 2012, 27 (01) : 95 - 96
  • [43] Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems
    Gerhard Fusch
    Saber Mohamed
    Ahmad Bakry
    Edward W. Li
    Sourabh Dutta
    Salhab el Helou
    Christoph Fusch
    European Journal of Pediatrics, 2024, 183 : 1245 - 1254
  • [44] Establishing a Contextualized Intervention Program for Noise Reduction in a Neonatal Intensive Care Unit
    Kose, Semra
    Sabetsarvestani, Raheleh
    Geckil, Emine
    Ozkilicaslan, Fatma Tokan
    Karaarslan, Fatih
    Tosun, Esra Erturk
    Altunhan, Huseyin
    HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2024, 17 (04) : 65 - 74
  • [45] Wound Care in the Neonatal Intensive Care Unit
    Fox, Miriam D.
    NEONATAL NETWORK, 2011, 30 (05): : 291 - 303
  • [46] Oral care in a neonatal intensive care unit
    Fernandez Rodriguez, Beatriz
    Pena Gonzalez, Lorena
    Cruz Calvo, Maria
    Chaves Sanchez, Fernando
    Pallas Alonso, Carmen Rosa
    de Alba Romero, Concepcion
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (08): : 953 - 957
  • [47] Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems
    Fusch, Gerhard
    Mohamed, Saber
    Bakry, Ahmad
    Li, Edward W.
    Dutta, Sourabh
    Helou, Salhab el
    Fusch, Christoph
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 183 (03) : 1245 - 1254
  • [48] Noise in the Neonatal Intensive Care Unit What Does the Evidence Tell Us?
    Casavant, Sharon G.
    Bernier, Katherine
    Andrews, Sheena
    Bourgoin, Allison
    ADVANCES IN NEONATAL CARE, 2017, 17 (04) : 265 - 273
  • [49] Troubling care in the neonatal intensive care unit
    Naylor, Lindsay
    Clarke-Sather, Abigail
    Weber, Michael
    GEOFORUM, 2020, 114 : 107 - 116
  • [50] ENVIRONMENTAL NOISE IN THE NEONATAL INTENSIVE-CARE UNIT - IMPLICATIONS FOR NURSING PRACTICE
    DEPAUL, D
    CHAMBERS, SE
    JOURNAL OF PERINATAL & NEONATAL NURSING, 1995, 8 (04) : 71 - 76