Tear evaporation rates: What does the literature tell us?

被引:11
作者
Wong, Stephanie [1 ]
Murphy, Paul J. [2 ,3 ]
Jones, Lyndon [1 ,2 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Ctr Ocular Res & Educ, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Sch Optometry & Vis Sci, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[3] Cardiff Univ, Sch Optometry & Vis Sci, Maindy Rd, Cardiff CF24 4HQ, S Glam, Wales
关键词
Tear evaporation; Dry eye; Meibomian gland dysfunction; Evaporimetry; MEIBOMIAN GLAND DYSFUNCTION; DRY EYE DISEASE; CONTACT-LENS WEAR; OCULAR SURFACE; FILM EVAPORATION; LIPID LAYER; INTERNATIONAL WORKSHOP; CLASSIFICATION SUBCOMMITTEE; CONFOCAL MICROSCOPY; WATER EVAPORATION;
D O I
10.1016/j.clae.2017.12.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: A previous literature review reported tear evaporation rates (TERs) from studies conducted on rabbits and humans between 1941 and 2003. Closer examination of the presented data revealed inaccuracies in the reporting of some values. This paper presents updated tables of TERs using values from the original papers cited in the review, in addition to incorporating new studies published between 2003 and 2016. Methods: A copy of each paper cited in the literature review was obtained and checked against the evaporation rate reported in the review. If the expected value could not be found in the cited paper, other papers by the same author were consulted to see if the value had been reported elsewhere. A PubMed and Scopus database search was conducted to find papers published on tear evaporimetry since 2003. Results: Two new tables of TERs were created, based on the values reported by the original author. To aid in interpretation, the majority of results are expressed in units of x 10(-7) g/cm(2)/sec. Where it was not possible to convert these values, some values are expressed as x 10(-7) g/sec, x 10(-7) g/sec/eye or W/min. Conclusions: Two new tables of TERs have been compiled to provide an accurate representation of the values reported in the original papers. These tables can be used as a point of reference for other researchers to compare their results.
引用
收藏
页码:297 / 306
页数:10
相关论文
共 83 条
[1]   Effect of Ambient Temperature on the Human Tear Film [J].
Abusharha, Ali A. ;
Pearce, E. Ian ;
Fagehi, Raied .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (05) :308-312
[2]   The Effect of Low Humidity on the Human Tear Film [J].
Abusharha, Ali A. ;
Pearce, E. Ian .
CORNEA, 2013, 32 (04) :429-434
[3]   Impact of duration of contact lens wear on the structure and function of the meibomian glands [J].
Alghamdi, Waleed M. ;
Markoulli, Maria ;
Holden, Brien A. ;
Papas, Eric B. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (02) :120-131
[4]   Changes in the Evaporation Rate of Tear Film After Digital Expression of Meibomian Glands in Patients With and Without Dry Eye [J].
Arciniega, Juan Carlos ;
Wojtowicz, Jadwiga Cristina ;
Mohamed, Engy Mostafa ;
McCulley, James Parker .
CORNEA, 2011, 30 (08) :843-847
[5]   Factors Affecting Evaporation Rates of Tear Film Components Measured In Vitro [J].
Borchman, Douglas ;
Foulks, Gag N. ;
Yappert, Marta C. ;
Mathews, Jonathan ;
Leake, Kim ;
Bell, Jim .
Eye & Contact Lens-Science and Clinical Practice, 2009, 35 (01) :32-37
[6]   TFOS DEWS II Definition and Classification Report [J].
Craig, Jennifer P. ;
Nichols, Kelly K. ;
Akpek, Esen K. ;
Caffery, Barbara ;
Dua, Harminder S. ;
Joo, Choun-Ki ;
Liu, Zuguo ;
Nelson, J. Daniel ;
Nichols, Jason J. ;
Tsubota, Kazuo ;
Stapleton, Fiona .
OCULAR SURFACE, 2017, 15 (03) :276-283
[7]   Exploring the Predisposition of the Asian Eye to Development of Dry Eye [J].
Craig, Jennifer P. ;
Wang, Michael T. M. ;
Kim, Dabin ;
Lee, Jung Min .
OCULAR SURFACE, 2016, 14 (03) :385-392
[8]   The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Interactions With the Tear Film Subcommittee [J].
Craig, Jennifer P. ;
Willcox, Mark D. P. ;
Argueeso, Pablo ;
Maissa, Cecile ;
Stahl, Ulrike ;
Tomlinson, Alan ;
Wang, Jianhua ;
Yokoi, Norihiko ;
Stapleton, Fiona .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) :123-156
[9]   Importance of the lipid layer in human tear film stability and evaporation [J].
Craig, JP ;
Tomlinson, A .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (01) :8-13
[10]  
Craig JP, 1998, ADV EXP MED BIOL, V438, P411