Percutaneous and endobronchial high dose rate brachytherapy for lung cancer

被引:0
作者
Imamura, M
Murata, T
Nagata, K
Kojima, H
Aoki, Y
Harima, Y
Uda, M
Tanaka, Y
Imamura, M
Yonezu, S
Umemoto, M
Saitoh, Y
机构
[1] KANSAI MED UNIV,DEPT INTERNAL MED 3,MORIGUCHI,OSAKA 570,JAPAN
[2] KANSAI MED UNIV,DEPT INTERNAL MED 1,MORIGUCHI,OSAKA 570,JAPAN
[3] KANSAI MED UNIV,DEPT THORAC SURG,MORIGUCHI,OSAKA 570,JAPAN
关键词
HDR brachytherapy; microSelectron; lung cancer;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Endobronchial and percutaneous high dose rate (HDR) brachytherapy was performed with a microSelectron HDR using iridium-192 as a radiation source. As spontaneous pain was uncontrollable by external beam radiation (EBR), chemotherapy, hyperthermia or a combination of these treatment methods, three patients with lung cancer infiltration into the chest wall underwent percutaneous HDR brachytherapy for palliation of severe pain. Selectron needles were inserted under CT guidance and the irradiation dose was set to 10 or 12 Gy at the point 1 cm from the center of the radiation source. A total of 2-4 selectron needles was introduced by means of a template. Irradiation was performed once a week for 1-2 weeks depending on the degree of alleviation of spontaneous pain. In all 3 cases, alleviation of spontaneous pain occured within 7 days after the completion of HDR brachytherapy, and the mean pain score decreased from a value of 2 to 1 within 2 weeks. After discharge from the hospital, the pain score remained between 1-4 in all 3 patients. One problem in percutaneous brachytherapy is the possible hindrance of multiple selectron needle insertion through the template by the ribs depending on the location of the lesion. Six patients aged 51-75 years were subjected to endobronchial HDR brachytherapy. Two of these patients had postoperative recurrence of lung cancer, and 3 patients received concomitant chemotherapy. Brachytherapy was performed 3.4 months (average) after the administartion of 40-70 Gy of EBR. Endobronchial irradiation was performed at a dose of 7 Gy, measured at 1 cm from the center of the radiation source, once a week over a 3 week period for a total of 21 Gy. With the exception of 2 patients who died due to systemic exacerbation, local control of the illness has been good. In endobronchial HDR brachytherapy, it is important to develop a system for altering radiation dose in response to changes in the caliber of the tracheobronchial tree and the degree of the tumor invasion under the bronchial mucosa.
引用
收藏
页码:997 / 1002
页数:6
相关论文
共 50 条
  • [41] Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer
    Maenhout, Metha
    van Vulpen, Marco
    Moerland, Marinus
    Peters, Max
    Meijer, Richard
    van den Bosch, Maurice
    Nguyen, Paul
    Frank, Steven
    van Zyp, Jochem van der Voort
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (02) : 161 - 166
  • [42] Analysis of dose distribution between contemporary and standard planning in high-dose-rate endobronchial brachytherapy based on three-dimensional imaging
    Sawicki, Marcin
    Lyczek, Jaroslaw
    Szutkowski, Zbigniew
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (05) : 462 - 468
  • [43] Endobronchial brachytherapy in the treatment of malignant lung tumours
    Escobar-Sacristán, JA
    Granda-Orive, JI
    Jiménez, TG
    Delgado, JM
    Baños, AR
    Valls, RS
    EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (03) : 348 - 352
  • [44] HIGH-DOSE-RATE BRACHYTHERAPY HAS A CURATIVE POTENTIAL IN PATIENTS WITH INTRALUMINAL SQUAMOUS-CELL LUNG-CANCER
    SUTEDJA, G
    BARIS, G
    VANZANDWIJK, N
    POSTMUS, PE
    RESPIRATION, 1994, 61 (03) : 167 - 168
  • [45] TREATMENT OF NON-SMALL-CELL LUNG-CANCER WITH EXTERNAL BEAM RADIOTHERAPY AND HIGH-DOSE RATE BRACHYTHERAPY
    AYGUN, C
    WEINER, S
    SCARIATO, A
    SPEARMAN, D
    STARK, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (01): : 127 - 132
  • [46] Thermoluminescence dosimetry for in-vivo verification of high dose rate brachytherapy for prostate cancer
    Das, R.
    Toye, W.
    Kron, T.
    Williams, S.
    Duchesne, G.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (03) : 178 - 184
  • [47] High-dose-rate brachytherapy boost for prostate cancer: Outcomes and genitourinary toxicity
    Bece, Andrej
    Patanjali, Nitya
    Jackson, Michael
    Whitaker, May
    Hruby, George
    BRACHYTHERAPY, 2015, 14 (05) : 670 - 676
  • [48] Thermoluminescence dosimetry for in-vivo verification of high dose rate brachytherapy for prostate cancer
    R. Das
    W. Toye
    T. Kron
    S. Williams
    G. Duchesne
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 178 - 184
  • [49] Reirradiation of recurrent head and neck cancer using high-dose-rate brachytherapy
    Rudzianskas, V.
    Inciura, A.
    Juozaityte, E.
    Rudzianskiene, M.
    Kubilius, R.
    Vaitkus, S.
    Kaseta, M.
    Adliene, D.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2012, 32 (05) : 297 - 303
  • [50] Mature results of a randomized trial comparing two fractionation schedules of high dose rate endoluminal brachytherapy for the treatment of endobronchial tumors
    Olivier M Niemoeller
    Barbara Pöllinger
    Maximilian Niyazi
    Stefanie Corradini
    Farkhad Manapov
    Claus Belka
    Rudolf M Huber
    Radiation Oncology, 8