Comparison of McGrath Series 3 and Macintosh Laryngoscopes for Tracheal Intubation in Patients With Normal Airway by Inexperienced Anesthetists A Randomized Study

被引:21
作者
Liu, Zi-Jia [1 ]
Yi, Jie [1 ]
Guo, Wen-Juan [1 ]
Ma, Chao [2 ]
Huang, Yu-Guang [1 ]
机构
[1] Chinese Acad Med Sci, Dept Anesthesia, Peking Union Med Coll Hosp, Peking Union Med Coll, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Dept Anat Histol & Embryol, Inst Basic Med Sci, Sch Basic Med,Peking Union Med Coll, Beijing 100730, Peoples R China
关键词
POTENTIAL DIFFICULT AIRWAYS; CONTROLLED-TRIAL; ENDOTRACHEAL INTUBATION; 5; VIDEOLARYNGOSCOPE; VIDEO-LARYNGOSCOPY; ADULT PATIENTS; METAANALYSIS; MANAGEMENT; OBSTETRICS; MANNEQUIN;
D O I
10.1097/MD.0000000000002514
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Difficult and failed intubations account for the major causes of morbidity and mortality in current anesthetic practice. Several devices including McGrath Series 3 videolaryngoscope are available which may facilitate tracheal intubation by improving view of the larynx compared with Macintosh blade laryngoscopy. But no studies demonstrate whether McGrath Series 3 performs better than Macintosh laryngoscope in normal airway intubations by inexperienced anesthetists so far. We therefore designed this randomized controlled study to compare McGrath with Macintosh in routine tracheal intubation performed by inexperienced anesthetists. In total, 180 adult patients with normal-appearing airways requiring orotracheal intubation for elective surgery were randomly allocated to be intubated by 9 inexperienced anesthetists with McGrath or Macintosh. The primary outcome was time to intubation. Ease of intubation was assessed by a 5-point ordinal scale. Intubation attempts/failures, best laryngoscopy view using the Cormack-Lehane grade, associated complications and hemodynamic changes during intubation were recorded. We found that there was no significant difference between McGrath and Macintosh in the median time to intubation (P = 0.46); the Cormack-Lehane views attained using McGrath were superior (P < 0.001); the difference of ease of intubation was statistically significant (P = 0.01). No serious trauma occurred in both groups. And there was statistically significant difference in the systolic blood pressure changes between 2 groups (P < 0.05). We demonstrated that in orotracheal intubation in patients with normal airway by inexperienced anesthetists, McGrath compared with the Macintosh allows superior glottis views, greater ease of intubation, less complications, and hemodynamic changes with noninferior intubation time. And it remained a potential selection for inexperienced anesthetists in uncomplicated intubation.
引用
收藏
页数:6
相关论文
共 25 条
  • [1] Failed tracheal intubation in obstetrics: a 6-year review in a UK region
    Barnardo, PD
    Jenkins, JG
    [J]. ANAESTHESIA, 2000, 55 (07) : 690 - 694
  • [2] Randomized controlled trial of the AP Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study
    Burdett, E.
    Ross-Anderson, D. J.
    Makepeace, J.
    Bassett, P. A.
    Clarke, S. G.
    Mitchell, V.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (06) : 983 - 988
  • [3] Anticipation of the difficult airway: preoperative airway assessment, an educational and quality improvement tool
    Cattano, D.
    Killoran, P. V.
    Iannucci, D.
    Maddukuri, V.
    Altamirano, A. V.
    Sridhar, S.
    Seitan, C.
    Chen, Z.
    Hagberg, C. A.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 276 - 285
  • [4] Chemsian Rv, 2014, Int J Crit Illn Inj Sci, V4, P35, DOI 10.4103/2229-5151.128011
  • [5] Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
    Cook, T. M.
    Woodall, N.
    Frerk, C.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (05) : 617 - 631
  • [6] DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS
    CORMACK, RS
    LEHANE, J
    [J]. ANAESTHESIA, 1984, 39 (11) : 1105 - 1111
  • [7] Di Marco Pierangelo, 2011, Anesth Analg, V112, P122, DOI 10.1213/ANE.0b013e3182005ef0
  • [8] Griesdale DEG, 2012, CAN J ANESTH, V59, P41, DOI 10.1007/s12630-011-9620-5
  • [9] Learning Endotracheal Intubation Using a Novel Videolaryngoscope Improves Intubation Skills of Medical Students
    Herbstreit, Frank
    Fassbender, Philipp
    Haberl, Helge
    Kehren, Clemens
    Peters, Juergen
    [J]. ANESTHESIA AND ANALGESIA, 2011, 113 (03) : 586 - 590
  • [10] Successful tracheal intubation with the McGrath® MAC video laryngoscope after failure with the Pentax-AWS™ in a patient with cervical spine immobilization
    Hyuga, Shunsuke
    Sekiguchi, Takemi
    Ishida, Takashi
    Yamamoto, Katsumi
    Sugiyama, Yuki
    Kawamata, Mikito
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2012, 59 (12): : 1154 - 1155