PACS: Communication and environment control system for disabled

被引:0
|
作者
Lauruska, V [1 ]
机构
[1] Siauliai Univ, Fac Technol, LT-5400 Shiauliai, Lithuania
来源
COMPUTERS HELPING PEOPLE WITH SPECIAL NEEDS: PROCEEDINGS | 2004年 / 3118卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
There are a lot of disabled people in the world. In many cases persons with severe disabilities who can't move or speak are isolated. These persons at least have one primitive way to communicate with others (it could be head movements, eye blink, voice intonations, mimics and others). The usage of electronics can help to transform it into understandable communication signs for others or into control signals for devices. Electronics means improve self-sufficiency of disabled people and enable communication with others. We have created communication and environment control system for physically disabled persons with speech and language impairments. A very important feature of this system is that it is controlled by one on/off type switch. Alternative input devices as head pointer, eye blink registrar, person's capacity registrar, suck-blow tube, etc, can be used instead of the similar switch.
引用
收藏
页码:922 / 925
页数:4
相关论文
共 50 条
  • [31] Nasal sniffing enables communication and environmental control for the severely disabled
    Sela, Lee
    Plotkin, Anton
    Weissbrod, Aharon
    Soroker, Nachum
    Sobel, Noam
    CHEMICAL SENSES, 2011, 36 (01) : E27 - E28
  • [32] PACS (PICTURE ARCHIVING AND COMMUNICATION-SYSTEM) IN NUCLEAR-MEDICINE
    BITTER, F
    HELLWIG, D
    WELLER, R
    ALMASI, L
    ADAM, WE
    RADIOACTIVE ISOTOPES IN CLINICAL MEDICINE AND RESEARCH /, 1988, : 443 - 447
  • [33] THE PICTURE ARCHIVING AND COMMUNICATION-SYSTEM (PACS) HOSPITAL - REALITY OR ILLUSION
    HRUBY, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (05): : 359 - 361
  • [34] Picture archiving and communication system (PACS): A progressive approach with small systems
    Osteaux, M
    VandenBroeck, R
    Verhelle, F
    deMey, J
    EUROPEAN JOURNAL OF RADIOLOGY, 1996, 22 (03) : 166 - 174
  • [35] Clearing away the fogging effect at a Picture Archiving and Communication System (PACS)
    Shim, YS
    Yang, DW
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2006, 108 (02) : 215 - 216
  • [36] MAJOR PICTURE ARCHIVING AND COMMUNICATION-SYSTEM (PACS) - EVALUATION PROJECTS
    GREBERMAN, M
    BAKKER, AR
    BRAUER, GW
    IRIE, G
    MUN, SK
    CARTER, ED
    GITLIN, JN
    SYSTEM SCIENCE IN HEALTH CARE, 2: HEALTH CARE SYSTEM AND ACTORS, 1988, 139 : 523 - 526
  • [37] Picture Archiving and Communication System (PACS) Implementation, Integration & Benefits in an Integrated Health System
    Mansoori, Bahar
    Erhard, Karen K.
    Sunshine, Jeffrey L.
    ACADEMIC RADIOLOGY, 2012, 19 (02) : 229 - 235
  • [38] COMMUNICATION AND STORAGE PROTOCOLS FOR PACS
    BAXTER, BS
    ZELEZNIK, MP
    COMPUTER, 1983, 16 (08) : 31 - 36
  • [39] PC reporting system for radiologists: practical use under PACS environment
    Nakata, N
    Yoshihiro, S
    Miida, K
    Tashima, M
    Sunakawa, Y
    Harada, J
    Tada, S
    Fukuda, K
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2001, 66 (01) : 17 - 24
  • [40] COMMUNICATION BY EYE CLOSURE - A MICROCOMPUTER-BASED SYSTEM FOR THE DISABLED
    GRATTAN, KTV
    PALMER, AW
    SORRELL, SR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (10) : 977 - 982