PACS: Communication and environment control system for disabled

被引:0
|
作者
Lauruska, V [1 ]
机构
[1] Siauliai Univ, Fac Technol, LT-5400 Shiauliai, Lithuania
来源
COMPUTERS HELPING PEOPLE WITH SPECIAL NEEDS: PROCEEDINGS | 2004年 / 3118卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
There are a lot of disabled people in the world. In many cases persons with severe disabilities who can't move or speak are isolated. These persons at least have one primitive way to communicate with others (it could be head movements, eye blink, voice intonations, mimics and others). The usage of electronics can help to transform it into understandable communication signs for others or into control signals for devices. Electronics means improve self-sufficiency of disabled people and enable communication with others. We have created communication and environment control system for physically disabled persons with speech and language impairments. A very important feature of this system is that it is controlled by one on/off type switch. Alternative input devices as head pointer, eye blink registrar, person's capacity registrar, suck-blow tube, etc, can be used instead of the similar switch.
引用
收藏
页码:922 / 925
页数:4
相关论文
共 50 条
  • [1] AN EYE-MOVEMENT COMMUNICATION-CONTROL SYSTEM FOR THE DISABLED
    LACOURSE, JR
    HLUDIK, FC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (12) : 1215 - 1220
  • [2] Lips-control assistive communication system for the serious disabled
    Chen, Shih-Chung
    Chien, Ching-Yi
    Chang, Wei-Min
    EDSSC: 2007 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS, VOLS 1 AND 2, PROCEEDINGS, 2007, : 1091 - 1094
  • [3] The Task Allocation Chart: Quality Control of a picture archive and communication system (PACS)
    Norton, GS
    Romlein, J
    Lyche, DK
    Richardson, RR
    MEDICAL IMAGING 1999 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1999, 3662 : 409 - 413
  • [4] The mechanomyogram as a channel of communication and control for the disabled
    Nolan, Y
    dePaor, A
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 4928 - 4931
  • [5] Image quality control of displays for the PACS environment
    Roehrig, H
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 337 - 342
  • [6] PACS (Picture Archiving Communication System) for Dentistry
    Patanachai, Nakintorn
    Uyyanonvara, Bunyarit
    Sinthanayothin, Chanjira
    Tharanon, Wichit
    Sompot, Palakon
    Muandet, Krikamol
    ECTI-CON 2008: PROCEEDINGS OF THE 2008 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 77 - +
  • [7] ELECTRONIC COMMUNICATION-SYSTEM FOR DISABLED
    ROWE, R
    MEDICAL JOURNAL OF AUSTRALIA, 1978, 1 (02) : 111 - 112
  • [8] Guiding and communication assistant for disabled in intelligent urban environment
    Szemes, PT
    Lee, JH
    Hashimoto, H
    Korondi, P
    PROCEEDINGS OF THE 2003 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM 2003), VOLS 1 AND 2, 2003, : 598 - +
  • [9] Outdoor environment recognition system on robotic communication terminals supporting mobility of elderly and disabled people
    Kayama, Kentaro
    Yairi, Ikuko Eguchi
    Igi, Seiji
    Systems and Computers in Japan, 2006, 37 (08): : 56 - 67
  • [10] Reengineering the picture archiving and communication system (PACS) process for digital imaging networks PACS
    Horton, MC
    Lewis, TE
    Kinsey, TV
    JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) : 59 - 61