Vertebral disk morphology of the lumbar spine: a retrospective analysis of collagen-sensitive mapping using dual-energy computed tomography

被引:12
作者
Schomig, Friederike [1 ]
Pumberger, Matthias [1 ]
Palmowski, Yannick [1 ]
Ditges, Ann-Kathrin [2 ]
Diekhoff, Torsten [2 ]
Gohler, Friedemann [2 ]
机构
[1] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Charitepl 1, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
关键词
Vertebral disk; Pathology; Tomography; X-ray computed; Spine; Collagen; BONE-MARROW EDEMA; CT; FRACTURES;
D O I
10.1007/s00256-020-03685-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives To investigate the diagnostic accuracy of collagen-sensitive maps derived from dual-energy computed tomography (DECT) for the detection of lumbar disk pathologies in a feasibility setting. Materials and methods We retrospectively reviewed magnetic resonance imaging (MRI), computed tomography (CT), and DECT datasets acquired in patients who underwent periradicular therapy of the lumbar spine from June to December 2019. Three readers scored DECT collagen maps, conventional CT, and MRI for presence, type, and extent of disk pathology. Contingency table analyses were performed to determine diagnostic accuracy using MRI as standard of reference. Interrater agreement within and between imaging modalities was evaluated by computing intraclass correlation coefficients (ICCs) and Cohen's kappa. Correlation between sum scores of anteroposterior disk displacement was determined by calculation of a paired t test. Results In 21 disks in 13 patients, DECT had a sensitivity of 0.87 (0.60-0.98) and specificity of 1.00 (0.54-1.00) for the detection of disk pathology. Intermodality agreement for anteroposterior disk displacement was excellent for DECT (ICC 0.963 [0.909-0.985]) and superior to CT (ICC 0.876 [0.691-0.95]). For anteroposterior disk displacement, DECT also showed greater within-modality interrater agreement (ICC 0.820 [0.666-0.916]) compared with CT (ICC 0.624 [0.39-0.808]). Conclusion Our data suggest that collagen-sensitive imaging has an added benefit, allowing more accurate evaluation of the extent of disk displacement with higher interrater reliability. Thus, DECT could provide useful diagnostic information in patients undergoing CT for other indications or with contraindications to MRI.
引用
收藏
页码:1359 / 1367
页数:9
相关论文
共 14 条
[1]   Dual-energy CT: theoretical principles and clinical applications [J].
Agostini, Andrea ;
Borgheresi, Alessandra ;
Mari, Alberto ;
Floridi, Chiara ;
Bruno, Federico ;
Carotti, Marina ;
Schicchi, Nicolo ;
Barile, Antonio ;
Maggi, Stefania ;
Giovagnoni, Andrea .
RADIOLOGIA MEDICA, 2019, 124 (12) :1281-1295
[2]   Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting [J].
Ai, Songtao ;
Qu, Mingliang ;
Glazebrook, Katrina N. ;
Liu, Yu ;
Rhee, Peter C. ;
Leng, Shuai ;
McCollough, Cynthia H. .
SKELETAL RADIOLOGY, 2014, 43 (09) :1289-1295
[3]   A Review of Lumbar Radiculopathy, Diagnosis, and Treatment [J].
Berry, James A. ;
Elia, Christopher ;
Saini, Harneel S. ;
Miulli, Dan E. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (10)
[4]   Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI [J].
Bierry, Guillaume ;
Venkatasamy, Aina ;
Kremer, Stephane ;
Dosch, Jean-Claude ;
Dietemann, Jean-Louis .
SKELETAL RADIOLOGY, 2014, 43 (04) :485-492
[5]   Virtual Noncalcium Dual-Energy CT: Detection of Lumbar Disk Herniation in Comparison with Standard Gray-Scale CT [J].
Booz, Christian ;
Noske, Jochen ;
Martin, Simon S. ;
Albrecht, Moritz H. ;
Yel, Ibrahim ;
Lenga, Lukas ;
Gruber-Rouh, Tatjana ;
Eichler, Katrin ;
D'Angelo, Tommaso ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
RADIOLOGY, 2019, 290 (02) :446-455
[6]   Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images [J].
Cao, Jian-xin ;
Wang, Yi-min ;
Kong, Xiang-quan ;
Yang, Cheng ;
Wang, Peng .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) :1109-1115
[7]   Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study [J].
Diekhoff, Torsten ;
Engelhard, Nils ;
Fuchs, Michael ;
Pumberger, Matthias ;
Putzier, Michael ;
Mews, Jurgen ;
Makowski, Marcus ;
Hamm, Bernd ;
Hermann, Kay-Geert A. .
EUROPEAN RADIOLOGY, 2019, 29 (01) :31-39
[8]   Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single-source volume CT scanner [J].
Diekhoffa, T. ;
Hermann, K. G. ;
Pumberger, M. ;
Hamm, B. ;
Putzier, M. ;
Fuchs, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 :59-65
[9]   Lumbar disc nomenclature: version 2.0 Recommendations of the combined task forces of the North American Spine Society, the American Society of Spine Radiology and the American Society of Neuroradiology [J].
Fardon, David F. ;
Williams, Alan L. ;
Dohring, Edward J. ;
Murtagh, F. Reed ;
Rothman, Stephen L. Gabriel ;
Sze, Gordon K. .
SPINE JOURNAL, 2014, 14 (11) :2525-2545
[10]   Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis [J].
Kosmala, Aleksander ;
Weng, Andreas Max ;
Heidemeier, Anke ;
Krauss, Bernhard ;
Knop, Stefan ;
Bley, Thorsten Alexander ;
Petritsch, Bernhard .
RADIOLOGY, 2018, 286 (01) :205-213