A comparison of frontal radiographs obtained from cone beam CT scans and conventional frontal radiographs of human skulls

被引:34
作者
van Vlijmen, O. J. C. [1 ,2 ]
Berge, S. J. [2 ,3 ]
Bronkhorst, E. M. [4 ]
Swennen, G. R. J. [2 ,5 ]
Katsaros, C. [6 ]
Kuijpers-Jagtman, A. M. [1 ,2 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthodont & Oral Biol, NL-6500 HB Nijmegen, Netherlands
[2] 3D Facial Imaging Res Grp Nijmegen Bruges, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Oral & Maxillofacial Surg, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, Med Ctr, Dept Prevent & Curat Dent, NL-6500 HB Nijmegen, Netherlands
[5] Acad Hosp St Jan, Dept Oral & Maxillofacial Surg, Brugge, Belgium
[6] Univ Bern, Dept Orthodont & Dentofacial Orthoped, CH-3012 Bern, Switzerland
关键词
Cephalometry; Three dimensional imaging; X-ray computed tomography; Reproducibility; Orthodontics; Maxillofacial; ACCURACY;
D O I
10.1016/j.ijom.2009.02.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed C, tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision(R) lot software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of I week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.
引用
收藏
页码:773 / 778
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1931, FORTSCHR ORTHOD
[2]   Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation [J].
Garcia Silva, Maria Alves ;
Wolf, Ulrich ;
Heinicke, Frank ;
Bumann, Axel ;
Visser, Heiko ;
Hirsch, Edgar .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) :640.e1-640.e5
[3]  
Ghafari J.G., 2006, RADIOGRAPHIC CEPHALO, V2nd ed., P267
[4]  
Gottlieb E L, 1991, J Clin Orthod, V25, P145
[5]  
Greiner M, 2007, J OROFAC ORTHOP, V68, P290, DOI 10.1007/s00056-007-0710-5
[6]  
Hajeer Mohammad Y, 2002, Int J Adult Orthodon Orthognath Surg, V17, P318
[7]  
Holly Broadbent B., 1931, Angle Oathod, V1, P45, DOI DOI 10.1043/0003-3219(1931)001<0045:ANXTAI>2.0.CO
[8]  
2
[10]   Comparison of conventional and cone beam CT synthesized cephalograms [J].
Kumar, V. ;
Ludlow, J. B. ;
Mol, A. ;
Cevidanes, L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (05) :263-269