Effect of Actual Gas Turbine Operating Conditions on Mist/Steam Cooling Performance in a Ribbed Passage

被引:2
作者
Gong, Jianying [1 ]
Gao, Tieyu [2 ]
Zeng, Junxiong [2 ]
Hou, Jianqiang [1 ]
Li, Zhen [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, MOE Key Lab Thermofluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Thermal Power Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
numerical simulation; internal cooling channel; mist; steam cooling; heat transfer enhancement; HEAT-TRANSFER CHARACTERISTICS; COOLED RECTANGULAR CHANNELS; FRICTION CHARACTERISTICS; HORIZONTAL TUBE; STEAM; DUCT; FLOW; AIR;
D O I
10.3390/en12102015
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study numerically examines the effect of actual gas turbine operating conditions on heat transfer characteristics in a ribbed passage with mist/steam cooling. A 60 degrees ribbed passage with aspect ratio of 1/1 was investigated at Reynolds number of 300,000, and steam cooling was used to provide a contrast. Three main factors were considered: coolant temperature, operating pressure, and wall heat flux density. The heat transfer enhancement mechanism of mist/steam cooling was explored, and the results showed that the heat transfer performance of mist/steam cooling was superior to steam cooling. When the coolant temperature varied from 300 to 500 degrees C, the average Nusselt number of mist/steam cooling decreased by 26.6%, and the heat transfer enhancement ratio dropped from 15% to 10%. As operating pressure increased, the heat transfer performance factor of mist/steam firstly increased and then decreased. At an operating pressure of 1.5 MPa, the heat transfer achieved its optimal performance, and the heat transfer enhancement ratio achieved its maximum value of 15.9%. Larger wall heat flux density provided less heat transfer enhancement. When the heat flux density increased from 100,000 to 300,000 Wm(-2), the average Nusselt number of mist/steam cooling decreased by 13.8%, while the heat transfer enhancement ratio decreased from 25.3% to 12.6%.
引用
收藏
页数:17
相关论文
共 24 条
[1]   Numerical model validation and prediction of mist/steam cooling in a 180-degree bend tube [J].
Dhanasekaran, T. S. ;
Wang, Ting .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (13-14) :3818-3828
[2]  
Dhanasekaran T.S.T.S., 2008, PROCEEDING ASME 2008, P611
[3]  
Elwekeel FNM, 2014, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5A
[4]  
Elwekeel FNM, 2013, PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 3A
[5]   Contrastive experimental study on heat transfer and friction characteristics in steam cooled and air cooled rectangular channels with rib turbulators [J].
Gong, Jianying ;
Gao, Tieyu ;
Li, Guojun .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (09) :3845-3854
[6]   Heat transfer and friction characteristics in steam cooled rectangular channels with rib turbulators [J].
Gong, Jianying ;
Gao, Tieyu ;
Li, Guojun .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (01) :357-364
[7]   Mist/steam cooling in a heated horizontal tube - Part 1: Experimental system [J].
Guo, T ;
Wang, T ;
Gaddis, JL .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2000, 122 (02) :360-365
[8]   Mist/steam cooling in a heated horizontal tube - Part 2: Results and modeling [J].
Guo, T ;
Wang, T ;
Gaddis, JL .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2000, 122 (02) :366-374
[9]   Mist/steam cooling in a 180-degree tube bend [J].
Guo, T ;
Wang, T ;
Gaddis, JL .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2000, 122 (04) :749-756
[10]   Heat Transfer and Pressure Losses of W-Shaped Small Ribs at High Reynolds Numbers for Combustor Liner [J].
Hagari, Tomoko ;
Ishida, Katsuhiko ;
Oda, Takeo ;
Douura, Yasushi ;
Kinoshita, Yasuhiro .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (09)