Real-Time 2-D Phased Array Vector Flow Imaging

被引:4
|
作者
Holbek, Simon [1 ,3 ]
Hansen, Kristoffer Lindskov [4 ,5 ]
Fogh, Nikolaj [6 ]
Moshavegh, Ramin [2 ,3 ]
Olesen, Jacob Bjerring [1 ,3 ]
Nielsen, Michael Bachmann [4 ,5 ]
Jensen, Jorgen Arendt [3 ]
机构
[1] BK Ultrasound, DK-2730 Herlev, Denmark
[2] BK Ultrasound, Res & Dev, DK-2730 Herlev, Denmark
[3] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[4] Copenhagen Univ Hosp, Dept Diagnost Radiol, DK-2100 Copenhagen, Denmark
[5] Univ Copenhagen, Dept Clin Med, DK-2100 Copenhagen, Denmark
[6] BK Ultrasound, DK-2730 Herlev, Denmark
关键词
3-D vector flow; blood velocity estimation; transverse oscillation; TRANSVERSE OSCILLATION; VELOCITY ESTIMATION; MAGNETIC-RESONANCE; BLOOD-FLOW; IN-VIVO; ASCENDING AORTA; PEAK VELOCITY; DOPPLER; ULTRASOUND; ECHOCARDIOGRAPHY;
D O I
10.1109/TUFFC.2018.2838518
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental offline 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner. A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSVs) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow rig with continuous laminar parabolic flow and in a pulsating flow pump system before being tested in vivo, where measurements were obtained on two healthy volunteers. Mean PSV from 11 cycles was 155 cm s(-1) with a precision of +/- 9.0% for the pulsating flow pump. In vivo, PSV estimated in the ascending aorta was 135 cm s(-1) +/- 16.9% for eight cardiac cycles. Furthermore, in vivo flow dynamics of the left ventricle and in the ascending aorta were visualized. In conclusion, angle independent 2-D VFI on a phased array has been implemented in real time, and it is capable of providing quantitative and qualitative flow evaluations of both the complex and fully transverse flow.
引用
收藏
页码:1205 / 1213
页数:9
相关论文
共 50 条
  • [31] Correcting Mutual Coupling and Poor Isolation for Real-Time 2-D Microwave Imaging Systems
    Case, Joseph T.
    Ghasr, Mohammad Tayeb
    Zoughi, Reza
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (05) : 1310 - 1319
  • [32] Real-time 2-D feature detection on a reconfigurable computer
    Benedetti, A
    Perona, P
    1998 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1998, : 586 - 593
  • [33] Real-time 2-D fluid simulation with a GPU acceleration
    School of Mechactronics Engineering, Harbin Institute of Technology, Harbin 150001, China
    Harbin Gongcheng Daxue Xuebao, 2008, 3 (278-284): : 278 - 284
  • [34] Researchers map real-time 2-D terahertz images
    Anderson, SG
    LASER FOCUS WORLD, 1996, 32 (07): : 30 - 31
  • [35] Real-Time 2-D Lidar Odometry Based on ICP
    Li, Fuxing
    Liu, Shenglan
    Zhao, Xuedong
    Zhang, Liyan
    SENSORS, 2021, 21 (21)
  • [36] Real-time visualization of salt crystallization in 2-D microchannels
    Shao, Jiaxin
    You, Lijun
    Jia, Na
    Kang, Yili
    Zhang, Kaiqiang
    GEOENERGY SCIENCE AND ENGINEERING, 2025, 246
  • [37] Time Domain Analysis of a 2-D Phased Array Antennas for Near Field Focusing Radiations
    Tuan, Shih-Chung
    Chou, Hsi-Tseng
    2012 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2012,
  • [38] Real-time GPU implementation of transverse oscillation vector velocity flow imaging
    Bradway, David Pierson
    Pihl, Michael Johannes
    Krebs, Andreas
    Tomov, Borislav Gueorguiev
    Kjaer, Carsten Straso
    Nikolov, Svetoslav Ivanov
    Jensen, Jorgen Arendt
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [39] Three-dimensional real-time synthetic aperture imaging using a rotating phased array transducer
    Nikolov, SI
    Jensen, JA
    Dufait, R
    Schoisswohl, A
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1585 - 1588
  • [40] CODED EXCITATION SYSTEM FOR IMPROVING THE PENETRATION OF REAL-TIME PHASED-ARRAY IMAGING-SYSTEMS
    ODONNELL, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (03) : 341 - 351