Computed tomography measurement of lung volume in preoperative assessment for living donor lung transplantation: Volume calculation using 3D surface rendering in the determination of size compatibility

被引:25
作者
Camargo, Jose J. P. [1 ]
Irion, Klaus L. [1 ,2 ,3 ,4 ]
Marchiori, Edson [4 ]
Hochhegger, Bruno [1 ,4 ]
Porto, Nelson S. [1 ]
Moraes, Beatriz G. [1 ]
Meyer, Gisela [1 ]
Caramori, Marlova [1 ]
Holemans, John A. [2 ,3 ]
机构
[1] Univ Fed Rio Grande do Sul, Post Grad Program Resp Sci, Porto Alegre, RS, Brazil
[2] Liverpool Heart & Chest Hosp NHS Trust, Liverpool, Merseyside, England
[3] Royal Liverpool Univ Hosp, Liverpool, Merseyside, England
[4] Univ Fed Rio de Janeiro, Postgrad Program Radiol, BR-21941 Rio De Janeiro, Brazil
关键词
lung transplantation; computed tomography X-ray; lung volume measurements; organ size; densitovolumetry; LOBAR TRANSPLANTATION; PULMONARY-EMPHYSEMA; VITAL CAPACITY; CT; RESOLUTION; SELECTION; THORAX;
D O I
10.1111/j.1399-3046.2008.01016.x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The objective of this study was to describe the use of CT volume quantification assessment of candidates for LLDLT. Six pediatric candidates for LDLLT and their donors were investigated with helical chest CT, as part of the preoperative assessment. The CT images were analyzed as per routine and additional post-processing with CT volume quantification (CT densitovolumetry) was performed to assess volume matching between the lower lobes of the donors and respective lungs of the receptors. CT images were segmented by density and region of interest, using post-processing software. Size matching was also assessed using the FVC formula. Compatible volumes were found in three cases. The other three cases were considered incompatible. All three recipients with compatible sizes survived the procedure and are alive and well. One patient with incompatible size was submitted to the procedure and died because of complications attributed to the incompatible volumes. One patient with incompatible size has subsequently grown and new measurements are to be taken to check the current volumes. Different donors are being sought for the remaining patient whose lung volumes were considered too big for the prospective transplant donor lobes. Under FVC formula criteria, all cases were considered compatible. CT volume quantification is an easy to perform, non-invasive technique that uses CT images for the preassessment of candidates for LDLLT, to compare the volume of the lower lobes from the donors with volume of each lung in the prospective recipients. Size matching based on CT densitovolumetry and FVC may differ.
引用
收藏
页码:429 / 439
页数:11
相关论文
共 28 条
[1]   Downsizing of the donor lung: Peripheral segmental resections and lobar transplantation [J].
Artemiou, O ;
Wieselthaler, G ;
Zuckermann, A ;
Wisser, W ;
Wekerle, T ;
Senbaklavaci, O ;
Birsan, T ;
Dekan, G ;
Kritzinger, M ;
Klepetko, W .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (07) :2899-2900
[2]   Pleural space problems after living lobar transplantation [J].
Backhus, LM ;
Sievers, EM ;
Schenkel, FA ;
Barr, ML ;
Cohen, RG ;
Smith, MA ;
Starnes, VA ;
Bremner, RM .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (12) :2086-2090
[3]   How to predict forced vital capacity after living-donor lobar-lung transplantation [J].
Date, H ;
Aoe, M ;
Nagahiro, I ;
Sano, Y ;
Matsubara, H ;
Goto, K ;
Kawada, M ;
Shimizu, N .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (05) :547-551
[4]   EFFECT OF SIZE (MIS)MATCHING IN CLINICAL DOUBLE-LUNG TRANSPLANTATION [J].
EGAN, TM ;
THOMPSON, JT ;
DETTERBECK, FC ;
LACKNER, RP ;
MILL, MR ;
OGDEN, WD ;
ARIS, RM ;
PARADOWSKI, LJ .
TRANSPLANTATION, 1995, 59 (05) :707-713
[5]   Virtual tools for imaging of the thorax [J].
Ferretti, GR ;
Bricault, I ;
Coulomb, M .
EUROPEAN RESPIRATORY JOURNAL, 2001, 18 (02) :381-392
[6]   Experimental study on size matching in a canine living-donor lobar lung transplant model [J].
Fujita, T ;
Date, H ;
Ueda, K ;
Nagahiro, I ;
Aoe, M ;
Shimizu, N .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (01) :104-109
[7]   HEART-LUNG TRANSPLANTATION - LESSONS LEARNED AND FUTURE HOPES [J].
GRIFFITH, BP ;
HARDESTY, RL ;
TRENTO, A ;
PARADIS, IL ;
DUQUESNOY, RJ ;
ZEEVI, A ;
DAUBER, JH ;
DUMMER, JS ;
THOMPSON, ME ;
GRYZAN, S ;
BAHNSON, HT .
ANNALS OF THORACIC SURGERY, 1987, 43 (01) :6-16
[8]  
Henry M, 2003, THORAX S2, V58, pii39, DOI [DOI 10.1136/TH0RAX.58.SUPPL_21I39, DOI 10.1136/THORAX.58.SUPPL_2.II39]
[9]   Interactive three dimensional volume rendering of spiral CT data: Current applications in the thorax [J].
Johnson, PT ;
Fishman, EK ;
Duckwall, JR ;
Calhoun, PS ;
Heath, DG .
RADIOGRAPHICS, 1998, 18 (01) :165-187
[10]   Impact of multidetector CT on donor selection and surgical planning before living adult right lobe liver transplantation [J].
Kamel, IR ;
Kruskal, JB ;
Pomfret, EA ;
Keogan, MT ;
Warmbrand, G ;
Raptopoulos, V .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :193-200