On an Aerodynamic Mechanism to Enhance Ion Transmission and Sensitivity of FAIMS for Nano-Electrospray Ionization-Mass Spectrometry

被引:54
作者
Prasad, Satendra [1 ]
Belford, Michael W. [1 ]
Dunyach, Jean-Jacques [1 ]
Purves, Randy W. [2 ]
机构
[1] Thermo Fisher Sci, San Jose, CA 95134 USA
[2] Univ Saskatchewan, Saskatoon, SK S7N 5A8, Canada
关键词
Sensitivity; FAIMS; Nano-ESI-FAIMS-MS; SIMION; CFD; PEPTIDE IDENTIFICATION; MS; FLOW; SELECTIVITY; SIMULATION; OPERATION; SPECTRA; MS/MS;
D O I
10.1007/s13361-014-0995-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simulations show that significant ion losses occur within the commercial electrospray ionization-field asymmetric waveform ion mobility spectrometer (ESI-FAIMS) interface owing to an angular desolvation gas flow and because of the impact of the FAIMS carrier gas onto the inner rf (radio frequency) electrode. The angular desolvation gas flow diverts ions away from the entrance plate orifice while the carrier gas annihilates ions onto the inner rf electrode. A novel ESI-FAIMS interface is described that optimizes FAIMS gas flows resulting in large improvements in transmission. Simulations with the bromochloroacetate anion showed an improvement of similar to 9-fold to give similar to 70% overall transmission). Comparable transmission improvements were attained experimentally for six peptides (2+) in the range of m/z 404.2 to 653.4 at a chromatographic flow rate of 300 nL/min. Selected ion chromatograms (SIC) from nano-LC-FAIMS-MS analyses showed 71% (HLVDEPQNLIK, m/z 653.4, 2+) to 95% (LVNELTEFAK, m/z 582.3, 2+) of ion signal compared with ion signal in the SIC from LC-MS analysis. IGSEVYHNLK (580.3, 2+) showed 24% more ion signal compared with LC-MS and is explained by enhanced desolvation in FAIMS. A 3-10 times lower limits of quantitation (LOQ) (< 15% RSD) was achieved for chemical noise limited peaks with FAIMS. Peaks limited by ion statistics showed subtle improvement in RSD and yielded comparable LOQ to that attained with nano-LC-MS (without FAIMS). These improvements were obtained using a reduced FAIMS separation gap (from 2.5 to 1.5 mm) that results in a shorter residence time (13.2 ms +/- 3.9 ms) and enables the use of a helium free transport gas (100% nitrogen).
引用
收藏
页码:2143 / 2153
页数:11
相关论文
共 45 条
[1]   An LC-IMS-MS Platform Providing Increased Dynamic Range for High-Throughput Proteomic Studies [J].
Baker, Erin Shammel ;
Livesay, Eric A. ;
Orton, Daniel J. ;
Moore, Ronald J. ;
Danielson, William F., III ;
Prior, David C. ;
Ibrahim, Yehia M. ;
LaMarche, Brian L. ;
Mayampurath, Anoop M. ;
Schepmoes, Athena A. ;
Hopkins, Derek F. ;
Tang, Keqi ;
Smith, Richard D. ;
Belov, Mikhail E. .
JOURNAL OF PROTEOME RESEARCH, 2010, 9 (02) :997-1006
[2]   Application of ESI-FAIMS-MS to the analysis of tryptic peptides [J].
Barnett, DA ;
Ells, B ;
Guevremont, R ;
Purves, RW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (11) :1282-1291
[3]   Characterization of a temperature-controlled FAIMS system [J].
Barnett, David A. ;
Belford, Michael ;
Dunyach, Jean-Jacques ;
Purves, Randy W. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (09) :1653-1663
[4]   Elimination of the helium requirement in high-field asymmetric waveform ion mobility spectrometry (FAIMS): beneficial effects of decreasing the analyzer gap width on peptide analysis [J].
Barnett, David A. ;
Ouellette, Rodney J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (14) :1959-1971
[5]   Maximizing Peptide Identification Events in Proteomic Workflows Using Data-Dependent Acquisition (DDA) [J].
Bateman, Nicholas W. ;
Goulding, Scott P. ;
Shulman, Nicholas J. ;
Gadok, Avinash K. ;
Szumlinski, Karen K. ;
MacCoss, Michael J. ;
Wu, Christine C. .
MOLECULAR & CELLULAR PROTEOMICS, 2014, 13 (01) :329-338
[6]  
Belford M., 2012, P 60 ASMS C MASS SPE
[7]  
Belford M., 2013, P 61 ASMS C MASS SPE
[8]  
Belford M. W., 2010, U. S. Patent, Patent No. [7,851,745, 7851745]
[9]   Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics [J].
Canterbury, Jesse D. ;
Yi, Xianhua ;
Hoopmann, Michael R. ;
MacCoss, Michael J. .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :6888-6897
[10]   Modelling a P-FAIMS with multiphysics FEM [J].
Cumeras, Raquel ;
Gracia, Isabel ;
Figueras, Eduard ;
Fonseca, Luis ;
Santander, Joaquin ;
Salleras, Marc ;
Calaza, Carlos ;
Sabate, Neus ;
Cane, Carles .
JOURNAL OF MATHEMATICAL CHEMISTRY, 2012, 50 (02) :359-373