Two-Level Damping Control for DFIG-based Wind Farm Providing Synthetic Inertial Service

被引:0
作者
Xi, Xinze [1 ,2 ]
Geng, Hua [1 ]
Yang, Geng [1 ]
机构
[1] Tsinghua Univ, Dept Automat, Beijing, Peoples R China
[2] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming, Peoples R China
来源
2016 52ND ANNUAL MEETING OF THE IEEE INDUSTRY APPLICATIONS SOCIETY (IAS) | 2016年
基金
中国国家自然科学基金; 国家高技术研究发展计划(863计划);
关键词
inertia response; wind power; torsional oscillation; low frequency oscillation; damping control; FREQUENCY REGULATION; POWER; GENERATORS; IMPACT;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The equivalent inertia of power system is reducing with the increasing wind power penetration. To alleviate this issue, more and more countries have put forward grid codes which require wind farms (WFs) to perform inertia control so as to provide synthetic inertia response as traditional synchronous generation (SG) does. It is found in this paper that the inertia control of the WF in a weak grid deteriorates drive-train torsion of wind turbine generators (WTGs). Furthermore, the WF emulating inertia response is involved in power system oscillations and a new critical low frequency oscillation mode is induced by the WF. These two potential risks restrict the WF to fulfill grid code requirements. To overcome this problem, this paper proposes a two-level damping control scheme consisting of a WTG level torsional oscillation damping control and a WF level low frequency oscillation damping control to enhance damping characteristic of the WF. Simulation results show that the two-level damping control can counteract these potential risks and facilitates the WF to meet grid code requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Oscillation analysis of a DFIG-based wind farm interfaced with LCC-HVDC
    YANG Lin
    XIAO Xiang Ning
    PANG Cheng Zong
    Science China(Technological Sciences), 2014, (12) : 2453 - 2465
  • [22] Gain Tuning Control Strategy for DFIG-based Wind Farms
    Xu, Yao
    Huang, Can
    Li, Fangxing
    Li, Xue
    Hu, Qinran
    2017 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2017,
  • [23] Comparison of Inertia Control Methods for DFIG-based Wind Turbines
    Zhang, Zhiheng
    Wang, Yi
    Li, Heming
    Su, Xiaoqing
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 960 - 964
  • [24] Robust Nonlinear Control of DFIG-Based Wind Farms for Damping Inter-Area Oscillations of Power Systems
    Li, Bo
    Yang, Shihai
    Yang, Bin
    Fang, Kaijie
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [25] Impact of wind farm integration on relay protection(2): DFIG-based wind farm electromagnetic transient equivalent model
    Zhang, B. (bhzhang@mail.xjtu.edu.cn), 1600, Electric Power Automation Equipment Press (33): : 1 - 7
  • [26] Fully-Distributed Deloading Operation of DFIG-Based Wind Farm for Load Sharing
    Dong, Zhen
    Li, Zhongguo
    Dong, Yi
    Jiang, Shuoying
    Ding, Zhengtao
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2021, 12 (01) : 430 - 440
  • [27] Inertia Control Strategy of DFIG-Based Wind Turbines Considering Low-Frequency Oscillation Suppression
    Liu, Haoming
    Yang, Suxiang
    Yuan, Xiaoling
    ENERGIES, 2022, 15 (01)
  • [28] Torsional vibration characteristics analysis of DFIG-based wind farm and its equivalent model
    Xie, Da
    Sun, Junbo
    Lu, Yupu
    Lou, Yucheng
    Gu, Chenghong
    Li, Furong
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 12 (05) : 646 - 656
  • [29] Simplified Failure Analysis Method for DFIG-based Wind Farm Outgoing Transmission Line
    Zhang Jinhua
    Zhang Baohui
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [30] Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid
    Yan, Cai
    Yao, Wei
    Wen, Jianfeng
    Fang, Jiakun
    Ai, Xiaomeng
    Wen, Jinyu
    IET RENEWABLE POWER GENERATION, 2020, 14 (13) : 2406 - 2415