Comparing 18-versus 12-mm spot size in hair removal using a Gentlease 755-nm Alexandrite laser

被引:20
作者
Nouri, K
Chen, H
Saghari, S
Ricotti, CA
机构
[1] Univ Miami, Sch Med, Dept Dermatol & Cutaneous Surg, Miami, FL USA
[2] Univ Miami, Sch Med, Dept Dermatol, Div Mohs Laser & Cutaneous Surg, Miami, FL 33152 USA
关键词
D O I
10.1111/j.1524-4725.2004.30162.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
BACKGROUND. Laser epilation is based on the principle of selective photothermolysis, absorption of laser energy by the target chromophore melanin. It is claimed that larger spot sizes may be more effective for hair removal at identical fluences. OBJECTIVE. To compare the efficacy of 18- vs. 12-mm spot size in hair removal using a Gentlelase Alexandrite laser from Candela Corporation (Boston, MA). METHODS. In this double-blind, randomized control trial, patients underwent laser-assisted hair removal on the axillary region. Regions were randomly selected and treated with either an 18- or a 12-mm spot size. Three treatments at 6-week intervals with a 755-nm Gentlelase Alexandrite laser (Candela Corp., Canton, MA) at a fluence of 16 J/cm(2) with cooling and delay times of 60 ms. Hair counts were taken before each treatment session and compared. The mean percentage hair reduction and student's paired t-test were used to compare 18 versus 12 mm versus control sites at each visit and compared it with the baseline hair count. RESULTS. There was a 10.3% difference in mean reduction favoring the 18-mm spot size treated area at the 6-month follow-up. CONCLUSION. Our results indicate that a larger spot size appears to be more effective for laser assisted hair removal.
引用
收藏
页码:494 / 497
页数:4
相关论文
共 15 条
[1]   A comparison of the long-pulse and short-pulse Alexandrite laser hair removal systems [J].
Boss, WK ;
Usal, H ;
Thompson, RC ;
Fiorillo, MA .
ANNALS OF PLASTIC SURGERY, 1999, 42 (04) :381-384
[2]  
DiBernardo BE, 2000, CLIN PLAST SURG, V27, P199
[3]   A clinical overview of hair removal using lasers and light sources [J].
Dierickx, C ;
Alora, MB ;
Dover, JS .
DERMATOLOGIC CLINICS, 1999, 17 (02) :357-+
[4]   Topical anesthesia for laser hair removal: Comparison of spot sizes and 755 nm versus 800 nm wavelengths [J].
Eremia, S ;
Newman, N .
DERMATOLOGIC SURGERY, 2000, 26 (07) :667-669
[5]   Laser hair removal: Long-term results with a 755 nm alexandrite laser [J].
Eremia, S ;
Li, CY ;
Umar, SH ;
Newman, N .
DERMATOLOGIC SURGERY, 2001, 27 (11) :920-924
[6]   Laser hair removal with alexandrite versus diode laser using four treatment sessions: 1-year results [J].
Eremia, S ;
Li, C ;
Newman, N .
DERMATOLOGIC SURGERY, 2001, 27 (11) :925-930
[7]   Alexandrite laser hair removal is safe for Fitzpatrick skin types IV-VI [J].
Garcia, C ;
Alamoudi, H ;
Nakib, M ;
Zimmo, S .
DERMATOLOGIC SURGERY, 2000, 26 (02) :130-134
[8]   Comparison of alexandrite laser and electrolysis for hair removal [J].
Görgü, M ;
Aslan, G ;
Aköz, T ;
Erdogan, B .
DERMATOLOGIC SURGERY, 2000, 26 (01) :37-41
[9]   Comparison of long-pulsed diode and long-pulsed alexandrite lasers for hair removal: A long-term clinical and histologic study [J].
Handrick, C ;
Alster, TS .
DERMATOLOGIC SURGERY, 2001, 27 (07) :622-626
[10]   Laser hair removal - A review and report on the use of the long-pulsed alexandrite laser for hair reduction of the upper lip, leg, back, and bikini region [J].
McDaniel, DH ;
Lord, J ;
Ash, K ;
Newman, J ;
Zukowski, M .
DERMATOLOGIC SURGERY, 1999, 25 (06) :425-430