Short-Latency Artifacts Associated with Concurrent TMS-EEG

被引:83
|
作者
Rogasch, Nigel C. [1 ,2 ]
Thomson, Richard H. [1 ,2 ]
Daskalakis, Zafiris J. [3 ]
Fitzgerald, Paul B. [1 ,2 ]
机构
[1] The Alfred, Monash Alfred Psychiat Res Ctr, Melbourne, Vic, Australia
[2] Monash Univ, Melbourne, Vic 3004, Australia
[3] Univ Toronto, Ctr Addict & Mental Hlth, Toronto, ON, Canada
基金
澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
Transcranial magnetic stimulation; Electroencephalography; Artifact; Muscle; TRANSCRANIAL MAGNETIC STIMULATION; INTERVAL CORTICAL INHIBITION; MOTOR CORTEX; RESPONSES; EXCITABILITY;
D O I
10.1016/j.brs.2013.04.004
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Concurrent transcranial magnetic stimulation and electroencephalography (TMS-EEG) is an emerging method for studying cortical network properties. However, various artifacts affect measurement of TMS-evoked cortical potentials (TEPs), especially within 30 ms of stimulation. Objective/hypothesis: The aim of this study was to assess the origin and recovery of short-latency TMS-EEG artifacts (<30 ms) using different stimulators and under different experimental conditions. Methods: EEG was recorded during TMS delivered to a phantom head (melon) and 12 healthy volunteers with different TMS machines, at different scalp positions, at different TMS intensities, and following paired-pulse TMS. Recovery from the TMS artifact and other short-latency artifacts were compared between conditions. Results: Following phantom stimulation, the artifact resulting from different TMS machines (Magstim 200, Magventure MagPro R30 and X100) and pulse shapes (monophasic and biphasic) resulted in different artifact profiles. After accounting for differences between machines, TMS artifacts recovered within similar to 12 ms. This was replicated in human participants, however a large secondary artifact (peaks at 5 and 10 ms) became prominent following stimulation over lateral scalp positions, which only recovered after similar to 25-40 ms. Increasing TMS intensity increased secondary artifact amplitude over both motor and prefrontal cortex. There was no consistent modulation of the secondary artifact following inhibitory paired-pulse TMS (interstimulus interval = 100 ms) over motor cortex. Conclusions: The secondary artifact observed in humans is consistent with activation of scalp muscles following TMS. TEPs can be recorded within a short period of time (10-12 ms) following TMS, however measures must be taken to avoid muscle stimulation. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:868 / 876
页数:9
相关论文
共 50 条
  • [31] TMS-EEG: CURRENT POSSIBILITIES AND FUTURE PROSPECTS
    Poydasheva, A. G.
    Bakulin, I. S.
    Legostaeva, L. A.
    Suponeva, N. A.
    Piradov, M. A.
    ZHURNAL VYSSHEI NERVNOI DEYATELNOSTI IMENI I P PAVLOVA, 2019, 69 (03) : 267 - 279
  • [32] TMS-EEG: A technique that has come of age?
    Fitzgerald, Paul B.
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (03) : 265 - 267
  • [33] Instrumentation for TMS-EEG Experiment: ArTGen and a Custom EEG Interface
    Varone, Giuseppe
    Boulila, Wadii
    Pascarella, Angelo
    Gasparini, Sara
    Aguglia, Umberto
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2024, 34 (04)
  • [34] Adapted Beamforming: A Robust and Flexible Approach for Removing Various Types of Artifacts from TMS-EEG Data
    Metsomaa, Johanna
    Song, Yufei
    Mutanen, Tuomas
    Gordon, Pedro
    Ziemann, Ulf
    Zrenner, Christoph
    Hernandez-Pavon, Julio
    BRAIN TOPOGRAPHY, 2024, 37 (05) : 659 - 683
  • [35] Phase-Amplitude Coupling of Neural Oscillations Can Be Effectively Probed with Concurrent TMS-EEG
    Glim, Sarah
    Okazaki, Yuka O.
    Nakagawa, Yumi
    Mizuno, Yuji
    Hanakawa, Takashi
    Kitajo, Keiichi
    NEURAL PLASTICITY, 2019, 2019
  • [36] Synchrosqueezing algorithm application in TMS-EEG analysis
    Bai, Yang
    Wang, Yong
    Niu, Zikang
    Li, Xiaoli
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 994 - 999
  • [37] Paired-pulse investigations of short-latency intracortical facilitation using TMS in humans
    Rothwell, JC
    TRANSCRANIAL MAGNETIC STIMULATIO N, 1999, (51): : 113 - 119
  • [38] SHORT-LATENCY AVOIDANCE RESPONSES
    ZIELINSKI, K
    BEHAVIORAL AND BRAIN SCIENCES, 1979, 2 (02) : 186 - 187
  • [39] Short-latency mycotoxic syndromes
    Landreau, Anne
    Bruneau, Chloe
    Aubriot, Edwige
    Lecot, Jeremy
    Le Roux, Gael
    ACTUALITES PHARMACEUTIQUES, 2021, 60 (609): : 39 - 43
  • [40] TMS-EEG co-registration: On TMS-induced artifact
    Veniero, Domenica
    Bortoletto, Marta
    Miniussi, Carlo
    CLINICAL NEUROPHYSIOLOGY, 2009, 120 (07) : 1392 - 1399