Relationship between ocular pulse amplitude and systemic blood pressure measurements

被引:44
作者
Grieshaber, Matthias C. [1 ]
Katamay, Robert [1 ]
Gugleta, Konstantin [1 ]
Kochkorov, Asan [1 ]
Flammer, Josef [1 ]
Orgul, Selim [1 ]
机构
[1] Univ Basel Hosp, Dept Ophthalmol, CH-4031 Basel, Switzerland
关键词
dynamic contour tonometry; intraocular pressure; ocular pulse amplitude; systemic blood pressure; DYNAMIC CONTOUR TONOMETRY; GOLDMANN APPLANATION TONOMETER; INTRAOCULAR-PRESSURE; CORNEAL THICKNESS; CLINICAL-EVALUATION; GLAUCOMA; MYOPIA; EYES; FLOW; HYPERTENSION;
D O I
10.1111/j.1755-3768.2008.01217.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study aimed to determine whether ocular pulse amplitude (OPA) measured with dynamic contour tonometry (DCT) is related to systemic blood pressure (BP) parameters. Blood pressure was measured continuously and simultaneously with OPA in one randomly selected eye in 29 healthy subjects. Systemic parameters of interest were: systolic and diastolic BPs and their difference (BP amplitude), and left ventricle ejection time (LVET; defined as the time between the diastolic trough and the incisural notch in the BP curve). In addition, the axial length (AL) of the eye was measured. Associations between OPA, AL and systemic cardiovascular parameters were analysed in a multivariate regression model. Measurements of OPA ranged from 1.0 mmHg to 4.9 mmHg (mean 2.3 +/- 0.9 mmHg, median 1.9 mmHg). In a univariate analysis with one predictor at a time, means of intraocular pressure (IOP) (p = 0.008), AL (p = 0.046) and LVET (p = 0.037) were significantly correlated with OPA, whereas systolic and diastolic BPs and their amplitude were not. A multiple linear regression analysis showed that mean IOP (p < 0.005), AL (p = 0.01) and LVET (p = 0.002) all independently contributed to OPA. The OPA readings measured with DCT in healthy subjects were not related to BP levels and amplitude. It seems that the OPA strongly depends on the time-course of the cardiac contraction. Regulating mechanisms in the carotid system as well as scleral rigidity may be responsible for dampening the direct effect of BP variations.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 40 条
[1]   Effect of a nifedipine induced reduction in blood pressure on the association between ocular pulse amplitude and ocular fundus pulsation amplitude in systemic hypertension [J].
Bayerle-Eder, M ;
Kolodjaschna, J ;
Wolzt, M ;
Polska, E ;
Gasic, S ;
Schmetterer, L .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (06) :704-708
[2]   FLUORESCEIN ANGIOGRAPHY DURING INDUCED OCULAR HYPERTENSION IN RETINITIS PIGMENTOSA [J].
BEST, M ;
GALIN, MA ;
BLUMENTHAL, M ;
TOYOFUKU, H .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 71 (06) :1226-+
[3]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[4]  
BLUMENTHAL M, 1971, ACTA OPHTHALMOL, V49, P805
[5]   Automatic detection of left ventricular ejection time from a finger photoplethysmographic pulse oximetry waveform: comparison with Doppler aortic measurement [J].
Chan, Gregory S. H. ;
Middleton, Paul M. ;
Celler, Branko G. ;
Wang, Lu ;
Lovell, Nigel H. .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (04) :439-452
[6]   Clinical evaluation of the Pascal® dynamic contour tonometer [J].
Detry-Morel, M. ;
Jamart, J. ;
Detry, M. B. ;
Ledoux, A. ;
Pourjavan, S. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2007, 30 (03) :260-270
[7]   Choroidal circulation in diabetic patients [J].
Dimitrova, G ;
Kato, S ;
Tamaki, Y ;
Yamashita, H ;
Nagahara, M ;
Sakurai, M ;
Kitano, S ;
Fukushima, H .
EYE, 2001, 15 (5) :602-607
[8]   Dynamic contour tonometry for post-LASIK intraocular pressure measurements [J].
Duba, I ;
Wirthlin, AC .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (05) :347-350
[9]  
EISENLOHR JE, 1962, INVEST OPHTH VISUAL, V1, P63
[10]   The impact of ocular blood flow in glaucoma [J].
Flammer, J ;
Orgül, S ;
Costa, VP ;
Orzalesi, N ;
Krieglstein, GK ;
Serra, LM ;
Renard, JP ;
Stefánsson, E .
PROGRESS IN RETINAL AND EYE RESEARCH, 2002, 21 (04) :359-393