Post-Fault Operation Strategy for Single Switch Open-Circuit Faults in Electric Drives

被引:10
作者
Eickhoff, Heinrich T. [1 ]
Seebacher, Roland [1 ]
Muetze, Annette [1 ]
Strangas, Elias G. [2 ]
机构
[1] Graz Univ Technol, Elect Drives & Machines Inst, A-8010 Graz, Austria
[2] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
关键词
Circuit faults; fault tolerance; inverters; torque; variable speed drives; SYNCHRONOUS MOTOR DRIVE; PERMANENT-MAGNET MACHINES; VOLTAGE-SOURCE INVERTERS; TOLERANT CONTROL; PMSM DRIVE; RELIABILITY; CONVERTERS; SYSTEM; PROGNOSTICS; DIAGNOSIS;
D O I
10.1109/TIA.2018.2807404
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Single switch open-circuit faults in three-phase ac drives lead to undesired effects and potentially to a total failure of the drive. This paper proposes a postfault operation strategy for such faults with a focus on the limitation of losses after the reconfiguration and thereby an extension of the possible range of operation. Furthermore, a method for the reduction of alternating torque components during the postfault operation of a squirrel cage induction machine drive is proposed. The performance of the postfault operation strategy and the alternating torque reduction method are shown both via simulations and experiments.
引用
收藏
页码:2381 / 2391
页数:11
相关论文
共 44 条
[1]   Postfault Operation of a Nine-Phase Six-Terminal Induction Machine Under Single Open-Line Fault [J].
Abdel-Khalik, Ayman Samy ;
Hamad, Mostafa S. ;
Massoud, Ahmed M. ;
Ahmed, Shehab .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (02) :1084-1096
[2]  
[Anonymous], 1943, CIRCUIT ANAL A C POW
[3]  
[Anonymous], P IEEE EN CONV C EXP
[4]   Fault Detection for IGBT Using Adaptive Thresholds During the Turn-on Transient [J].
Antonio Rodriguez-Blanco, Marco ;
Vazquez-Perez, Amsi ;
Hernandez-Gonzalez, Leobardo ;
Golikov, Victor ;
Aguayo-Alquicira, Jesus ;
May-Alarcon, Manuel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) :1975-1983
[5]   A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System [J].
Antonio Rodriguez-Blanco, Marco ;
Claudio-Sanchez, Abraham ;
Theilliol, Didier ;
Gerardo Vela-Valdes, Luis ;
Sibaja-Teran, Pedro ;
Hernandez-Gonzalez, Leobardo ;
Aguayo-Alquicira, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1625-1633
[6]   Innovative remedial strategies for inverter faults in IPM synchronous motor drives [J].
Bianchi, N ;
Bolognani, S ;
Zigliotto, M ;
Zordan, M .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) :306-314
[7]  
Bianchi N, 1996, IEEE POWER ELECTRON, P1542, DOI 10.1109/PESC.1996.548786
[8]   Experimental fault-tolerant control of a PMSM drive [J].
Bolognani, S ;
Zordan, M ;
Zigliotto, M .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :1134-1141
[9]   Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2517-2533
[10]   An induction motor drive system with improved fault tolerance [J].
Corrêa, MBD ;
Jacobina, CB ;
da Silva, ERC ;
Lima, AMN .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (03) :873-879